LiftMaster J J (CUBE STYLE) Manual

LiftMaster J Manual

LiftMaster J manual content summary:

  • LiftMaster J | J (CUBE STYLE) Manual - Page 1
    'S MANUAL MODELS: J H HJ INDUSTRIAL DUTY DOOR OPERATOR NEW! Cube Style Electrical Box FACTORY SET C2 Wiring See page 8 for other wiring configurations 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR
  • LiftMaster J | J (CUBE STYLE) Manual - Page 2
    emergency manual door operation. Model HJ: Includes both floor level disconnect systems stated above. REVERSING EDGE:......(Optional) Electric or pneumatic sensing device attached to the bottom edge of door. A REVERSING EDGE IS STRONGLY RECOMMENDED FOR ALL COMMERCIAL OPERATOR INSTALLATIONS. REQUIRED
  • LiftMaster J | J (CUBE STYLE) Manual - Page 3
    manual hoist hand chain systems, the handing of the operator must be determined at the time of order. The handing is indicated by last letter of the model name (R or L). The hand chain wheel can not be switched on site. If your installation causes the hand chain to hang in the door opening, hook
  • LiftMaster J | J (CUBE STYLE) Manual - Page 4
    on page 3. Refer to the illustration and instructions below that suits your application. 1a. Wall Mounting The operator should generally be installed below the door shaft, and as close to the door as possible. The optimum distance between the door shaft and operator drive shaft is between 12" - 15
  • LiftMaster J | J (CUBE STYLE) Manual - Page 5
    chain to disconnect the door from the door operator and and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model J instructions for manual operation. Manual Disconnect for Models J and HJ WA
  • LiftMaster J | J (CUBE STYLE) Manual - Page 6
    please contact your local LiftMaster WIRING: Authorized Dealer. For wiring of your sensing device to the operator, refer to the wiring diagram supplied with your opera- If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions pro- tor. See
  • LiftMaster J | J (CUBE STYLE) Manual - Page 7
    of the cover) for all connections described below. If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM. RNING WARNING UTION DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING
  • LiftMaster J | J (CUBE STYLE) Manual - Page 8
    your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual
  • LiftMaster J | J (CUBE STYLE) Manual - Page 9
    On all models with type B2 control wiring, a terminal bracket marked R1 R2 R3 is located on the outside of the electrical enclosure. All standard radio control receivers (single channel residential type) may be mounted to this bracket. The operator will then open a fully closed door, close a fully
  • LiftMaster J | J (CUBE STYLE) Manual - Page 10
    SERVICING OR ADJUSTING THE OPERATOR. Be sure you have read and understand all Safety Instructions included in this manual. CAUTION Be sure the owner or person(s) responsible for operation of the door have read and understand the Safety Instructions, know how to electrically operate the door
  • LiftMaster J | J (CUBE STYLE) Manual - Page 11
    the following chart. ITEM Drive Chain Sprockets Clutch Belt Fasteners Manual Disconnect Bearings & Shafts PROCEDURE Check for excessive slack. SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE
  • LiftMaster J | J (CUBE STYLE) Manual - Page 12
    ) OVERLOAD (BK) IR (SEE NOTE #1) (BK) 230V MODELS 115V MODELS PUR BL YEL GY BL/BK 1 8 5 23 4 BL/BK 230 VOLT - 1 PHASE MOTOR CONNECTION CL 4 3 OP 4 3 OP 2 1 CL 6 5 OP 5 6 CL 1 2 (YE) (BL) (PUR) TO MOTOR (GY) 3 (YEL) STOP OPEN (OR) SAFETY EDGE R1 (OR) (BR) EXTERNAL
  • LiftMaster J | J (CUBE STYLE) Manual - Page 13
    NOTES: 1) TO REVERSE MOTOR DIRECTION: INTERCHANGE PURPLE & GRAY MOTOR LEADS AT CONTACTOR 1 & 3. 2) WIRE MUST BE REMOVED FOR 23OV 1PH OPERATION. **- Transformer Primary & Relay Voltage same as Line Voltage. 1 2 3 4 5 7 10 L1 L2 L3 OPEN CLOSE STOP EXT. INTLK. TO OPEN AND CLOSE SAFETY EDGE L1
  • LiftMaster J | J (CUBE STYLE) Manual - Page 14
    BL/BK GY BRN PUR BRN YEL BL/BK 1 2 O/L* 3 BL/BK 230 VOLT - 3 PHASE MOTOR CONNECTION L3 3 PHASE POWER IN L2 L1 3 STOP 4 (YEL) OPEN * - SEE NOTE #2 460 VOLT - 3 PHASE MOTOR CONNECTION OVERLOAD (SEE NOTE #2) (BK) CL (BK) (BK) 4 3 OP 4 3 OP 2 1 CL 6 5 (BR) EXTERNAL INTERLOCK
  • LiftMaster J | J (CUBE STYLE) Manual - Page 15
    THREE PHASE WIRING DIAGRAM 1742-3 RADIO RECEIVER R1 R2 R3 AUX.TERMINAL BLOCK FOR RADIO C AUX.OPEN L/S NO NC ORANGE YELLOW RED RED YELLOW PURPLE ORANGE OPEN LIMIT SWITCHES OPEN L/S NC C ORANGE ORANGE PURPLE RED YELLOW GREY PURPLE CLOSE A1 A2 13 14 5 6 3 4 1 2 PURPLE PURPLE
  • LiftMaster J | J (CUBE STYLE) Manual - Page 16
    ELECTRICAL BOX - ILLUSTRATED PARTS S2 S1 S6 S5 S3 S7 S8 S4 L3 S9 L1 10 5 L5 L8 3 L6 L2 1 2 11 9 L7 5 4 8 L2 L6 L4 7 6 16
  • LiftMaster J | J (CUBE STYLE) Manual - Page 17
    box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. Please consult a parts and service
  • LiftMaster J | J (CUBE STYLE) Manual - Page 18
    ILLUSTRATED PARTS - Model J 5 6 7 1 8 9 C8 C20 C10 C9 D1 D7 D4 D8 D11 D3 D10 D9 D2 D5 D6 C4 C21 C6 C16 C24 C7 C17 C14 C18 C3
  • LiftMaster J | J (CUBE STYLE) Manual - Page 19
    available. Please consult a parts and service representative regarding availability of individual components. Refer to page 11 for all repair part ordering information. INDIVIDUAL PARTS ITEM PART # DESCRIPTION QTY 1 10-15569 Motor Plate 1 2 75-15012 Side Plate LH 1 3 75-15013 Side Plate
  • LiftMaster J | J (CUBE STYLE) Manual - Page 20
    ILLUSTRATED PARTS - Model H 5 6 D1 D7 D4 D8 D11 D3 C12 1 D10 D9 D2 D5 D6 C15 C6 C2 C17 C5 C7 C19 C16 C18 C4 C25 C18 C19
  • LiftMaster J | J (CUBE STYLE) Manual - Page 21
    Please consult a parts and service representative regarding availability of individual components. Refer to page 11 for all repair part ordering information. K72-12563 CLUTCH SHAFT REPLACEMENT KIT ITEM PART # DESCRIPTION QTY C1 10-10166 Clutch Plate 1 C2 10-10882 Chain Guide 1 C3 11-15605
  • LiftMaster J | J (CUBE STYLE) Manual - Page 22
    ILLUSTRATED PARTS - MODEL HJ 22 8 5 6 1 7 L1 L7 L4 L10 L9 L8 L11 L3 C17 L2 L5 L6 C7 C2 C20 C6 C5 C22 C23 C30 C14 C19 O10 O5 O8 O4 O7 O9 9 C13 C29 C3 C24 C13
  • LiftMaster J | J (CUBE STYLE) Manual - Page 23
    -100 Roll Pin 1/8 x 1" 2 K75-12560 LEFT HAND DISCONNECT ASSY KIT ITEM PART # DESCRIPTION QTY L1 10-10707 Disconnect Support Bracket 1 L2 10-10708 Yoke 1 L3 10-10875 Disconnect Lever 1 L4 10-10898-L Interlock Switch Actuator 1 L5 11-10878 Disconnect Shaft 1 L6 19-8A-12 12 ft. Of Sash
  • LiftMaster J | J (CUBE STYLE) Manual - Page 24
    EXTERNAL TERMINAL BLOCK Sensing Device RADIO CONTROL ALL CONTROL WIRING TYPES TIMER TO CLOSE w/ WARNING LIGHT ALL CONTROL WIRING TYPES * T1 WIRING - RADIO TO OPEN ONLY EXTERNAL INTERLOCK Warning Light will activate 15 sec. before door closes. 11 12 13 14 Auxiliary Terminal Block Remove Jumper
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

OWNER'S MANUAL
MODELS:
J
H HJ
INDUSTRIAL DUTY DOOR OPERATOR
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
2 YEAR WARRANTY
C2 Wiring
FACTORY SET
See page 8
for other wiring
configurations
Cube Style
Electrical Box
NEW!
NOT FOR RESIDENTIAL USE
LISTED
DOOR
OPERATOR
41B6