OPERATION AND MAINTENANCE » MAINTENANCE MAINTENANCE Disconnect power before servicing. DESCRIPTION External Entrapment Protection System Manual Release Gate Accessories Electrical Mounting Hardware Batteries Operator Warning Signs TASK Check and test for proper operation Check and test for proper operation Inspect for wear or damage Check all for proper operation Inspect all wire connections Check for tightness Replace Inspect for wear or damage Make sure they are present NOTES: • Severe or high cycle usage will require more frequent maintenance checks. • Inspection and service should always be performed anytime a malfunction is observed or suspected. • When servicing, please do some "house cleaning" of the operator and the area around the operator. Pick up any debris in the area. Clean the operator as needed. • It is suggested that while at the site voltage readings be taken at the operator. Using a Digital Voltmeter, verify that the incoming voltage to the operator it is within ten percent of the operator's rating. • See page 33 for instructions on how to adjust the gate force. MONTH X X X CHECK AT LEAST ONCE EVERY 6 MONTHS 3 YEARS X X X X X X 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

40
OPERATION
AND MAINTENANCE
» MAINTENANCE
MAINTENANCE
NOTES:
Severe or high cycle usage will require more frequent maintenance checks.
Inspection and service should always be performed anytime a malfunction is
observed or suspected.
When servicing, please do some “house cleaning” of the operator and the area
around the operator. Pick up any debris in the area. Clean the operator as
needed.
It is suggested that while at the site voltage readings be taken at the operator.
Using a Digital Voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.
See page 33 for instructions on how to adjust the gate force.
CHECK AT LEAST ONCE EVERY
DESCRIPTION
TASK
MONTH
6 MONTHS
3 YEARS
External Entrapment Protection System
Check and test for proper operation
X
Manual Release
Check and test for proper operation
X
Gate
Inspect for wear or damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Mounting Hardware
Check for tightness
X
Batteries
Replace
X
Operator
Inspect for wear or damage
X
Warning Signs
Make sure they are present
X