LiftMaster LA400UL LA400UL Wiring Diagram

LiftMaster LA400UL Manual

LiftMaster LA400UL manual content summary:

  • LiftMaster LA400UL | LA400UL Wiring Diagram - Page 1
    WIRING DIAGRAM Model LA400UL CONTROLS To reduce the risk of INJURY or DEATH: • DISCONNECT power and battery BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. • To be compliant with UL325 and industry safety guidelines, qualified monitored external
  • LiftMaster LA400UL | LA400UL Wiring Diagram - Page 2
    LA400UL LiftMaster approuvés (consulter la page des accessoires). • Avant les travaux, consulter le manuel pour les instructions Service OPEN CLOSE POWER SBC OPN POWER 1 EYE ONLY 2 EYE/ EDGE 31 2 3 EEDOYEGNYELEEY/ CEOEDYMGEE/ EYE/ EDGE SCBOCM OSPBNC COLPSN SCTLPS STP CCOOMM TO MAIN BOARD
  • 1
  • 2

Press and hold
STOP...
...then press and
hold CLOSE...
...then press and hold OPEN
until "Er" shows.
CODE SEQUENCE NUMBER
The first number shown is the most
recent code (example: “01”). The
display will show the sequence of
codes that occurred starting with “01”
and going up to code “20”.
CODE NUMBER
The second number shown after the code
sequence number is the code itself
(31-99, example” “31”).
A SECOND LATER
....
The operator will show the code sequence number followed by the code number:
Diagnostic Codes
TO VIEW THE CODES:
LiftMaster.com
© 2018, LiftMaster
All Rights Reserved
01-39240-10
LiftMaster System
Installed System
Informational
External Entrapment Protection
Inherent Entrapment Protection
WIRING DIAGRAM
Model LA400UL
CODE
MEANING
SOLUTION
31
Main control board has experienced an internal
failure.
Disconnect all power, wait 15 seconds, then
reconnect power (reboot). If issue continues,
replace main control board.
32
Linear Drive Disengaged (Arm 1)
Disengage then re-engage arm. Check wiring and
connections.
33
Linear Drive Disengaged (Arm 2)
35
Max-Run-Time Exceeded Error
Check for an obstruction, then reprogram the
limits.
36
Product ID Error
Was the control board just replaced? If so, erase
limits, enter limit setup mode and set limits. If
not, disconnect all power, wait 15 seconds, then
reconnect power before changing product ID
harness.
37
Product ID Failure
Unplug product ID harness then plug back in.
Disconnect all power, wait 15 seconds, then
reconnect power before replacing product ID
harness.
38
Hard Stop Limit (Arm 1)
Limit may be set too tightly against a
non-resilient hard stop (re-adjust limit). Operator
may be at end of travel (re-adjust mounting).
39
Hard Stop Limit (Arm 2)
40
Battery overvoltage
Too much voltage on the battery. Check harness.
Make sure there is NOT a 24V battery on a 12V
system.
41
Battery overcurrent
Possible short of the battery charge harness.
Check harness. Make sure you do NOT have a
12V battery on a 24V system.
42
No battery at boot up
Check battery connections and installation.
Replace batteries if depleted to less than 20V on
a 24V system or less than 10V on a 12V system.
Make sure there is NOT a single 12V battery on a
24V system.
43
Failure or missing EXIT loop
Failure or missing loop (SHORT or OPEN -
LiftMaster Plug-in Loop Detector only) Check
loop wiring throughout connection. May be a
short in the loop, or an open connection in the
loop.
44
Failure or missing SHADOW loop
45
Failure or missing INTERRUPT loop
46
Wireless edge battery low
Replace batteries in wireless edge.
51
Pass-point not detected (Arm 1)
Check yellow pass-point wiring. If limits are not
accurate, reprogram.
52
Pass-point not detected (Arm 2)
53
Brownout occurred
AC/DC board supply dipped below allowable
level. Review power supply and wiring. If
rebooting, ensure enough time for discharge of
power to force a fresh boot.
54
Wireless Second Operator Communication Error
Check the second operator for power. If OFF,
restore power and try to run the system. If
powered, deactivate the wireless feature and then
reprogram the second operator.
60
Minimum number of monitored entrapment
protection devices not installed.
Review monitored entrapment protection device
connections. This swing gate operator will
operate only after installation of a minimum of
one external safety device in either the open or
close direction.
61
CLOSE EYE/INTERRUPT held more than 3
minutes
Check wired input on main board; check for
alignment or obstruction.
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
64
CLOSE EYE/INTERRUPT held more than 3
minutes
Check wired input on expansion board; check for
alignment or obstruction.
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
67
Wireless edge triggered more than 3 minutes
Check wired input for wiring issue or
obstruction.
68
Wireless edge loss of monitoring
Check wireless edge inputs.
69
Wireless edge triggered
IF an obstruction occurred, no action required. If
an obstruction did NOT occur, check inputs and
wiring.
70
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If
an obstruction did NOT occur, check alignment,
inputs, and wiring on main board.
71
CLOSE EDGE triggered, causing reversal,
preventing close, or canceling TTC
72
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
73
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If
an obstruction did NOT occur, check alignment,
inputs, and wiring on expansion board.
74
CLOSE EYE/EDGE triggered, causing reversal
and preventing close or canceling TTC
75
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
80
Close input (EYE/EDGE) communication fault
from other operator
Check inputs and communication method
between operators, either wired bus or radio.
Ensure operator is powered. May have to erase
the wireless communication and reprogram the
two operators.
81
Open input (EYE/EDGE) communication fault
from other operator
82
Close input (EYE/EDGE) communication fault
(expansion board)
Check the connections between the main board
and the expansion board.
83
Open input (EYE/EDGE) communication fault
(expansion board)
84
Non-monitored device detected on the wireless
safety system
Non-monitored contact closure devices are not
supported. Make sure connected devices are
monitored. Check edges for proper orientation
and resistive end cap connection.
91
Force Reversal (Operator 1)
Check for obstruction. If no obstruction, check
that the mechanical assembly is engaged and
free to move. See section on Limit and Force
Adjustment, and Obstruction Test in the manual.
92
Force Reversal (Operator 2)
93
RPM / STALL Reversal (Operator 1)
Check for obstruction. If no obstruction, check
the operator wiring and that the mechanical
assembly is engaged and free to move. Replace
APE assembly.
94
RPM / STALL Reversal (Operator 2)
99
Normal Operation
No action required
To reduce the risk of INJURY or DEATH:
DISCONNECT power and battery BEFORE installing or servicing operator.
Replace ONLY with fuse of same type and rating.
To be compliant with UL325 and industry safety guidelines, qualified monitored
external entrapment protection devices such as photoelectric sensors or edge
sensors are required to be installed with this operator at each entrapment zone.
Use ONLY LiftMaster approved entrapment protection devices (refer to the
accessory page of manual).
See manual prior to servicing regarding maintenance and required safety testing.
CODE COLOR KEY:
DIAGNOSTICS
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
SBC
OPN
CLS
STP
COM
C
4321
Control Station
Photoelectric Sensors
for close cycle
Edge Sensor
for close cycle
OR
Edge Sensor
for open cycle
Photoelectric Sensors
for open cycle
ENTRAPMENT
PROTECTION
LOOPS
Fire Department
CONTROLS
LOCKS
ACCESSORY
POWER
ENTRAPMENT
PROTECTION
CONTROLS
OR
24 Vdc
switched
OR
OR
Expansion Board
(Optional Accessory)
Maglock
(Optional)
(not provided)
Solenoid Lock
(Optional)
(not provided)
24 Vdc
always on
Photoelectric Sensors
for open or close cycle
Photoelectric Sensor
for open or close cycle
Edge Sensor
for open or close
cycle
Edge Sensor
for open or close
cycle
Photoelectric Sensor
for open or close cycle
Control Board
COAXIAL CABLE
ANTENNA
(see below)
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
(see below)
AUXILIARY RELAYS
LOOPS
Shadow Loop
Exit Loop
Interrupt Loop
Normally Open
Common
Normally Closed
Normally Open
Common
Normally Closed
SWITCH SETTINGS
1
2
3
RELAY 1
RELAY 2
OFF
Relay always off
Relay always off
OFF
OFF
OFF
OFF
ON
Energizes at open
limit
Energizes at open limit
OFF
OFF
ON
Energizes when not
at close limit
Energizes when not at
close limit
OFF
ON
ON
Energizes when
motor is on
Energizes when motor
is on
ON
OFF
OFF
Energizes 3 seconds
prior and during gate
motion
Energizes 3 seconds prior
and during gate motion
ON
OFF
ON
Energizes with AC or
solar power
Energizes with battery
power
ON
ON
OFF
Energizes when gate
is tampered with
Energizes when gate is
tampered with
ON
ON
ON
LEDs will blink
cycle count
Not used
RED
/
GREEN
LIGHT FUNCTIONALITY
1
2
3
Red light
wired to AUX RELAY 1.
Green light
wired to AUX RELAY 2.
AUX RELAY 1 SWITCHES
OFF
Red light OFF*
OFF
OFF
CLOSED
GATE STATE
AUX RELAY 2 SWITCHES
Green light OFF
1
2
3
ON
ON
ON
OPENING
OPEN
CLOSING
Defined Mid Stop
Undefined Mid Stop
Timer more than
5 seconds
Timer less than
5 seconds
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
Red light ON/FLASH
Red light OFF
Red light ON/FLASH
n/a
Red light ON
Red light OFF
Red light ON/FLASH
Green light OFF
Green light ON
Green light OFF
Green light OFF
n/a
Green light OFF
Green light ON
Solar Panels (Optional)
20W minimum - 60W maximum, wired in parallel
10W 12V
10W 12V
Black
Red
ALARM
CONTROL BOARD
Battery
12V 7AH
Battery
12V 7AH
Yellow
PRODUCT
ID
White
White
RESET BUTTON
PLUG-IN
TRANSFORMER
CONTROL BOARD
Input Power Connection
HOT
NEUTRAL
GROUND
J15 Plug
Black
Red
Black
Red
Black
Red
Black
Red
Optional 33AH Battery Configuration
For 33AH battery configuration please use Universal Solar Harness
Kit K94-37236.
The Large Solar Control Box (XLSOLARCONTUL) can be used with
either 7AH or 33AH batteries.
Earth Ground Rod
Wireless Edge Kit
Model LMWEKITU
Universal Solar Harness Kit (K94-37236)
For 7AH or 33AH batteries
Shadow Loop
Exit Loop
Interrupt Loop
Access Control
Device
Black
Green
White
Attach to outlet metal
chassis with a single screw
Diode
Control Stations
Jumper
N.C.
(Back of the Output Housing)
Outlet
Outlet
PRIMARY
OPERATOR
SECONDARY
OPERATOR
TO SCROLL THROUGH THE SAVED CODES:
Press the OPEN button to cycle to the most recent code ("01"). Press the CLOSE button
to cycle to the oldest code (up to “20”).