LiftMaster LA500 Solar Gate Access System Daily Cycle Chart Manual

LiftMaster LA500 Manual

LiftMaster LA500 manual content summary:

  • 1

SOLAR GATE ACCESS SYSTEM DAILY CYCLE CHART
The LA500 Solar Gate Access System utilizes an
innovative Power Management System to deliver
power when needed most for operating a gate while
minimizing power consumption at all other times.
Power is provided to the gate operator via batteries.
The batteries are charged from a solar panel(s)
connected to the operator control board. The number
of solar panels required is determined by whether the
application is for a single or dual gate, daily cycle rate,
number of accessories and region of the country.
The map and daily cycle rate shown are
approximations based upon the average solar radiation
and the temperature effects on batteries in the given
regions. Local geography and weather conditions
may require additional solar panels. Low Power Draw
or Wireless Accessories are recommended in order
to minimize power draw, as added accessories draw
power and affect the daily cycle rate.
Solar panel(s) must be located in an open area clear
of obstructions and shading for the entire day. Snow,
heavy fog or heavy rain affect solar panel performance
and charge rate. The LA500 is not supported in
climates where temperatures reach below -4°F. This
is due to the effect of cold weather on batteries and a
reduced number of hours of sunlight during the winter
months. Solar panels should be cleaned regularly to
ensure proper operation.
Expansion board and LiftMaster
®
Internet Gateway
not recommended for solar applications. These
features will substantially decrease the cycle rate
and standby time.
1
1
1
2
3
3
4
4
4
Not Available
Not Available
NUMBER OF CYCLES PER DAY (SOLAR-DUAL SWING GATE)
ACCESSORY
POWER
DRAW (mA)
ZONE 1
(6 Hrs
sunlight/day)
(2) 33AH
batteries required
0
51
50
31
11
100
13
28
18
0
122
71
48
50
98
50
28
100
75
30
11
200
32
0
195
116
79
50
169
92
57
100
143
300
50
69
37
(2) 33AH
batteries required
(2) 33AH
batteries required
(4 Hrs
sunlight/day)
(2 Hrs
sunlight/day)
ZONE 2
ZONE 3
20W SOLAR PANEL
NOTE:
20W would be two
10W (12V) panels in series.
40W SOLAR PANEL
NOTE:
40W would be two
20W (12V) panels in series.
60W SOLAR PANEL
NOTE:
Must Use 24V Panel
Swing Gate
Installation
(12 ft. 800 lb. gate)
200
76
NUMBER OF CYCLES PER DAY (SOLAR-SINGLE SWING GATE)
ACCESSORY
POWER
DRAW (mA)
ZONE 1
(6 Hrs
sunlight/day)
(2) 33AH
batteries required
0
283
166
112
50
227
116
66
100
174
69
25
0
300
270
185
50
300
215
134
100
300
300
116
162
86
(2) 33AH
batteries required
(2) 33AH
batteries required
(4 Hrs
sunlight/day)
(2 Hrs
sunlight/day)
ZONE 2
ZONE 3
20W SOLAR PANEL
NOTE:
20W would be two
10W (12V) panels in series.
40W SOLAR PANEL
NOTE:
40W would be two
20W (12V) panels in series.
60W SOLAR PANEL
NOTE:
Must Use 24V Panel
0
118
50
71
25
100
30
66
43
Swing Gate
Installation
(12 ft. 800 lb. gate)
LA500
Number identifies zone. LA500 not supported/available in Zone 4.
NOTES