Lowrance HELM-1 Drive Unit Network Quad User Manual

Lowrance HELM-1 Drive Unit Manual

Lowrance HELM-1 Drive Unit manual content summary:

  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 1
    AND OPERATING PARAMETERS........ 7 SETTING THE DISPLAY DAMPING 8 SETTING THE SPEED AND LOG UNITS 9 SPEED AND LOG CALIBRATION 10 1 - MANUAL CALIBRATION - CAL 11 2 - MANUAL CALIBRATION - LOG CAL 12 3 - AUTOMATIC CALIBRATION - AUTO CAL 13 RESETTING THE DEAD RECKONED DISTANCE ....... 15 USING THE
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 2
    GENERAL INTRODUCTION TO B&G NETWORK The B&G Network range of instruments is designed to be used as individual units or connected together to form an integrated navigational system. A single network cable is used to carry data and power between units. The latest technology and screened cables
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 3
    INTRODUCTION TO NETWORK QUAD CONT'D The Network QUAD unit has three adjustable alarms: 1. Shallow water alarm 2. Deep water alarm 3. Anchor alarm An internal alarm buzzer will sound when an alarm condition is met and the display will flash. The alarm is broadcast to all other Network Instruments in
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 4
    EXAMPLES SYSTEMS USING NETWORK QUAD Only one Network QUAD unit should have speed and depth sensors connected to it and set to transducer mode. Up to three more Network QUAD (set to repeater mode) or QUAD REPEATER units can be connected on to the system network. QUAD Main unit QUAD QUAD QUAD
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 5
    SELECTING THE DISPLAY MODE The Network QUAD unit has two operating modes. The correct mode must be selected for your Network system to operate properly. tYPEt Transducer mode, the unit uses and displays speed and depth data from sensors connected directly into the display unit. tYPEr Repeater
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 6
    USING THE SPEED KEY Boat speed information is permanently displayed in the top area of the LCD. Press the SPEED key to cycle through the following options: SPEED Current boat speed in Knots, can also be displayed in MPH. AVERAGE Average boat speed since the last reset of SPEED the trip log. MAX
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 7
    speed can be displayed in Knots or MPH. This setting also changes the log units to Nautical or Statute Miles. CAL Manual boat speed and log calibration. LOG CAL Manual boat speed and log calibration. AUTO CAL Automatic boat speed and log calibration. dr Reset Dead Reckoned Distance. When in
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 8
    SETTING THE DISPLAY DAMPING Damping allows the response time of the displayed speed value to be slowed down if it is to jumpy in rough weather, or to sped it up when the conditions are calm. The damping works by averaging the values over a set time period; the longer the time period the smoother the
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 9
    SETTING THE SPEED AND LOG UNITS The Network QUAD can be set to display boat speed in Knots or MPH. If boat speed is in Knots then log is in Nautical Miles. If boat speed is in MPH then log is in Statute Miles. Press SPEED key to display current boat speed. Press SETUP key twice. The speed digits
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 10
    and the boats hull characteristics. Three methods are available with the Network QUAD unit, two manual adjustments and one automatic: MANUAL CALIBRATION 1. CAL The displayed boat speed value is corrected manually to read a known measured speed. 2. LOG The units calibration figure (Hz/Knot) is CAL
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 11
    METHOD 1. - MANUAL CALIBRATION - CAL This procedure requires a reference boat speed with which to compare the Network QUAD units displayed boat speed. For example, another boat with an
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 12
    METHOD 2. - MANUAL CALIBRATION - LOG CAL If the log or boat speed is in error by a known percentage then this method allows the calibration figure or LOG CAL
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 13
    METHOD 3. - AUTOMATIC CALIBRATION - AUTO CAL This procedure will automatically and accurately calibrate the boat speed and log and is the recommended method for most boats. NOTE: AUTO CAL can be aborted any time by pressing the SETUP key, then the SPEED key. • Select two markers that are easily
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 14
    AUTOMATIC CALIBRATION PROCEDURE Distance measured on a chart Start Run 1 Stop Run 1 Stop Run 2 Start Run 2 Start Run 3 Stop Run 3 ABORTING AUTO CAL 610-HB-0503-05 14
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 15
    RESETTING THE DEAD RECKONED DISTANCE This facility allows the Dead Reckoned (DR) distance log to be reset. The Network QUAD unit cannot display the DR information, however Network SPEED and Network DATA both display it. Press SPEED key to display the current boat speed. Press SETUP key 6 times to
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 16
    USING THE DEPTH KEY The current water depth is permanently displayed in the bottom LCD area in metres, feet or fathoms. The unit is factory set to metres. The depth displayed is from the depth datum, see DEPTH DATUM. Press the DEPTH key to cycle through the following options: CAL The Depth Datum
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 17
    THE DEPTH DATUM - CAL The depth datum CAL is an offset calibration value used to determine the displayed information reference point. It is added to the actual measured water depth to display the depth from the waterline, the depth sensor (transducer) or the keel/outdrive depth. The Network QUAD
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 18
    SETTING THE DEPTH DATUM CAL zero, depth from transducer. CAL positive, depth from waterline. CAL negative, depth from keel. NOTE: If the CAL LOCK is set then the CAL value cannot be changed. Consult your B&G dealer for further advice. Press DEPTH key to display depth datum CAL. Press SETUP key to
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 19
    SETTING THE DEPTH UNITS The Network QUAD unit can be set to display depth in Metres, Feet or Fathoms. The selected units are used for displayed depth information on all Network instruments on the entire Network system. Press DEPTH key to display the current depth. Press SETUP key twice. The depth
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 20
    alarms and flash their displays, except Network WIND and Network TACK which do not have alarms. See NETWORK ALARMS at the end of this manual. Shallow Alarm • Factory set to 1.0m, (3.2ft, 0.5 fathoms). • Adjustable range 0 - 180m, 0 - 590ft, 0 - 98.4 fa. Deep Alarm • Factory set to 10.0m, (32.8ft
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 21
    ENABLING/DISABLING THE SHALLOW ALARM Press DEPTH key to display the shallow alarm. Press SETUP key, Press ENTER key, Use S or T to the alarm state will the alarm state enable/disable the be displayed. display will flash. alarm. Press ENTER to memorise the change. ADJUSTING THE SHALLOW ALARM
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 22
    ENABLING/DISABLING THE DEEP ALARM Press DEPTH key Press SETUP key, to display the deep the alarm state will alarm. be displayed. Press ENTER key, the alarm state display will flash. Use S or T to enable/disable the alarm. Press ENTER to memorise the change. ADJUSTING THE DEEP ALARM VALUE
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 23
    USING THE ANCHOR ALARM The Anchor Alarm uses two adjustable alarm limits. The alarm will sound if the water is deeper or shallower, by the set values, than the original depth of water when the alarm was enabled. This allows you to adjust your anchor chain according to the tides. The anchor alarm
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 24
    ENABLING/DISABLING THE ANCHOR ALARM Press DEPTH key to display ANCHOR ALARM Press SETUP key, to display alarm state. Press ENTER key, the alarm state display will flash. Use S or T to enable or disable the alarm. Press ENTER to memorise the new alarm state. Press DEPTH key to display the
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 25
    ADJUSTING THE ANCHOR ALARM SHALLOW LIMIT Press DEPTH key to display anchor alarm. Press SETUP key Press ENTER key, twice to display the the value display shallow value. will flash. Use S or T to change the value. Press ENTER to memorise the new value and enable the alarm. Press DEPTH key to
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 26
    USING THE TIMER/TEMP KEY Press the TIMER/TEMP key to cycle through the options: TRIP LOG A reset log that can be displayed in Nautical miles or Statute Miles. This is determined by the selection of the displayed speed units (see SETTING THE SPEED AND LOG UNITS). It also resets the Maximum and
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 27
    RESETTING THE TRIP LOG The Trip Log is reset to zero and starts again as soon as the ENTER key is pressed. Press TIMER key to display the TRIP LOG. Press SETUP key, Display flashes. Press ENTER key, the display resets to zero, and remains flashing. Press TIMER key to display the TRIP LOG. 610-
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 28
    SETTING THE TIMERS AND LAP TIMER The Lap Timer can be used to `freeze' the displayed time with any of the three Timers. Press the TIMER key to display the timers. Press SETUP key 1 10 min. 2 5 min. 3 Count-up The display will flash. Press ENTER key, the display is set to the selected starting
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 29
    SETTING THE TEMPERATURE UNITS The sea temperature can be displayed in Celsius or Fahrenheit. Press TEMP key until the sea temperature is displayed. Press SETUP key once to display the current units. Press ENTER if the units are to be changed. The display will flash. Use S or T keys to change the
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 30
    CALIBRATING THE TEMPERATURE SENSOR Temperature calibration should only be carried out when the built-in sea water temperature sensor (part of the speed sensor) is considered to be inaccurate. The temperature of the water will have to be measured with an accurate temperature sensing device, this
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 31
    USING THE LIGHTS KEY The Network QUAD Display unit has 3 levels of illumination and off, controlled by the LIGHTS key. It also changes the illumination level of the key legends. The LIGHTS key is always illuminated so even in complete darkness the key can be located. • LIG 0 • LIG 3 • LIG 2 • LIG 1
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 32
    NETWORK ALARMS The Network QUAD unit has an internal buzzer that will sound when an alarm condition is met on a Network unit that has alarm functions ie. Network DEPTH and Network QUAD for depth alarms and Network PILOT for Watch Alarm and Off Course alarms. The unit will also display which alarm is
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 33
    the error number should be recorded. Switch off the supply and disconnect the faulty unit. Return it with the error number to your dealer for servicing. 610-HB-0503-05 33
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 34
    INSTALLATION The display heads are supplied with a clip-in mounting bracket which allows for easy installation, access from behind is not necessary to secure the unit in place. However to prevent theft and permanently fix the unit in position, locking studs and thumb nuts are supplied. SITING THE
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 35
    INSTALLATION DATA 110.0mm Network QUAD 110.0mm SPEED DEPTH TIMER SETUP LIGHTS TEMP ENTER Mounting bracket 82.0mm 82.0mm 25.0mm 65.0mm Rubber Gasket Fit the gasket around the mounting bracket Bulkhead Gasket Locking stud fixing Speed sensor connector Depth sensor connector Network
  • Lowrance HELM-1 Drive Unit | Network Quad User Manual - Page 36
    SPECIFICATION PHYSICAL PARAMETERS Construction Window Display Dimensions: Weight: High impact ABS plastic Acrylic Back-lit Liquid Crystal Display: Large Digits: 15mm (0.6") Small Digits: 10mm (0.4") 110 x 110 x 25.4mm (4 x 4 x 1") Requires 65mm (2.6") depth behind bulkhead for display barrel 0.3
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

CONTENTS
DEEP ALARM
GENERAL INTRODUCTION TO B&G NETWORK
.........
2
ENABLING/DISABLING THE DEEP ALARM
..................
22
INTRODUCTION TO NETWORK QUAD
.........................
3
ADJUSTING THE DEEP ALARM VALUE
.......................
22
EXAMPLE SYSTEMS USING NETWORK QUAD
...........
4
ANCHOR ALARM
SELECTING THE DISPLAY MODE
................................
5
USING THE ANCHOR ALARM
.......................................
23
ENABLING/DISABLING THE ANCHOR ALARM
............
24
USING THE SPEED KEY
................................................
6
ADJUSTING THE ANCHOR ALARM SHALLOW LIMIT .25
CALIBRATION AND OPERATING PARAMETERS
........
7
ADJUSTING THE ANCHOR ALARM DEEP LIMIT
.........
25
SETTING THE DISPLAY DAMPING
...............................
8
SETTING THE SPEED AND LOG UNITS
.......................
9
USING THE TIMER/TEMP KEY
.....................................
26
SPEED AND LOG CALIBRATION
................................
10
RESETTING THE TRIP LOG
..........................................
27
1 - MANUAL CALIBRATION - CAL
................................
11
SETTING THE TIMERS AND LAP TIMER
.....................
28
2 - MANUAL CALIBRATION - LOG CAL
........................
12
SETTING THE TEMPERATURE UNITS
.........................
29
3 - AUTOMATIC CALIBRATION - AUTO CAL
...............
13
CALIBRATING THE TEMPERATURE SENSOR
............
30
RESETTING THE DEAD RECKONED DISTANCE
.......
15
USING THE LIGHTS KEY
..............................................
31
USING THE DEPTH KEY
..............................................
16
NETWORK ALARMS
.....................................................
32
THE DEPTH DATUM - CAL
...........................................
17
FAULT AND ERROR MESSAGES
.................................
33
SETTING THE DEPTH DATUM
.....................................
18
SETTING THE DEPTH UNITS
.......................................
19
INSTALLATION
..............................................................
34
SITING THE UNIT
...........................................................
34
DEPTH ALARMS
...........................................................
20
MOUNTING THE UNIT
...................................................
34
SHALLOW ALARM
ENABLING/DISABLING THE SHALLOW ALARM
.........
21
SPECIFICATION
............................................................
36
ADJUSTING THE SHALLOW ALARM VALUE
..............
21
610-HB-0503-05
1