Mackie SP1200 Instruction Manual

Mackie SP1200 Manual

Mackie SP1200 manual content summary:

  • Mackie SP1200 | Instruction Manual - Page 1
    Instruction Manual ZONE A INPUTS MASTER VOLUME 3 0 3 6 9 15 30 55 1 2 3 4 OFF SP1200 MUSIC CONTROLLER OL ON STATUS COMM PORT POWER SP1200 OF MACKIE DESIGNS INC "MACKIE.","MACKIE INDUSTRIAL", REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS
  • Mackie SP1200 | Instruction Manual - Page 2
    NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED and maintenance (servicing) instructions in the literature Servicing - The user should not attempt to service the SP1200 beyond those means described in this operating manual. All other servicing should be referred to the Mackie Service
  • Mackie SP1200 | Instruction Manual - Page 3
    assigned to operate over the entire system when manually operated with a switch connected to the PAGING for an optional ambient microphone that can sample the ambient noise level in the room. Part No. 0001207 Rev. A 1/02 © 2002 All Rights Reserved. Mackie Industrial. Printed in U.S.A. SP1200 - 3
  • Mackie SP1200 | Instruction Manual - Page 4
    input signal connected here or the program signal on the expansion bus. See "EXPANSION IN/OUT" on page 18 for more information. Note: The SP1200 combines the left and right input signals into mono after the expansion bus I/O. DIRECT OUTPUT is a buffered line-level output providing the stereo signal
  • Mackie SP1200 | Instruction Manual - Page 5
    Sound Palette Control PC application software for centralized computer control of up to 32 zones, as well as communication between SP1200s TRADEMARKS OF MACKIE DESIGNS INC "MACKIE.","MACKIE INDUSTRIAL", NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS:
  • Mackie SP1200 | Instruction Manual - Page 6
    REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE
  • Mackie SP1200 | Instruction Manual - Page 7
    REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE
  • Mackie SP1200 | Instruction Manual - Page 8
    REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE. DEBRANCHER AVANT DE
  • Mackie SP1200 | Instruction Manual - Page 9
    TRADEMARKS OF MACKIE DESIGNS INC "MACKIE.","MACKIE INDUSTRIAL", AND NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. AVIS: RISQUE INPUT 4 PRIORITY OFF/ON AMBIENT MIC OFF/ON OFF ON SP1200 SWITCH SETTINGS 1234 ZONE A I 0 12345678 AMP ADDRESS LOCAL
  • Mackie SP1200 | Instruction Manual - Page 10
    , using the SP1200 in a mono application. A Digital Satellite Service (DSS) is own zone. The Paging Mic can be manually operated with the Paging Mic Control Switch, SP1200s, Multiple Zones: Room Combining-Zones In this example, a dividing wall can be extended to divide the room into two. The Mackie
  • Mackie SP1200 | Instruction Manual - Page 11
    as well (+40). Note: The Paging Mic has priority over the system, including Input 4. 4. Is there a manual switch for paging? Up to two switches can be connected to the SP1200 PAGING MIC CONTROL to manually engage the paging microphone. Otherwise, the paging mic can be voice-activated. Adjust the VOX
  • Mackie SP1200 | Instruction Manual - Page 12
    of Cable (24AWG) Distance Chart for SP1200 Expansion Bus Cable 0 100 200 300 Cable Assembly (Part Number F3D111-06 the remote control and the SP1200 before suffering transmission losses. Strip connections, depending on the distance between the SP1200 and the remote control. The REMOTE connector
  • Mackie SP1200 | Instruction Manual - Page 13
    ON S2 12345678 J12 J11 J10 J9 J8 S3 Note: There are several settings that can be changed inside the SP1200. These settings should be made prior to installing the SP1200. CAUTION: These servicing instructions are for use by qualified personnel only. To avoid electric shock, do not perform any
  • Mackie SP1200 | Instruction Manual - Page 14
    J6 on the Filter Board. J1 J2 D22 C40 D3 C23 U25 C54 SP1200 FILTER BOARD Q1 S1 EQ ENGAGE 3 2 EQ BYPASS 1 J6 L6 C91 1 and 2 for 8-ohm operation Jumper pins 2 and 3 for 70V or 100V operation SP1200 - 14 SP1200 AMP BOARD JP1 C15 C9 C7 JP2 C17 C18 C8 C10 100V or 8Ω/250W 70V or
  • Mackie SP1200 | Instruction Manual - Page 15
    See Appendix C for instructions on how to change the operating voltage configuration. Thermal Considerations IMPORTANT: The SP1200 is convection cooled output. If this should occur, identify the cause of the problem and take corrective action, such as providing better ventilation, installing
  • Mackie SP1200 | Instruction Manual - Page 16
    Quick Start This isn't a substitute for reading the entire instruction manual, which is the only way to fully understand how the SP1200 works. However, the Quick Start provides a quick overview so you can get the SP1200 set up and working right away. Make sure the power switch is off while setting
  • Mackie SP1200 | Instruction Manual - Page 17
    CONTROL connector is provided to connect a manual paging switch. Connect a normally-open switch SP1200 to provide wallmounted input select, program signal volume control, and local mic volume control. RS485 A PC can be connected to the RS485 port to provide computer control using the SPLinker Sound
  • Mackie SP1200 | Instruction Manual - Page 18
    switches, one for the left input and one for the right input. Bus Assign These internal switches are used if you have two or more SP1200s connected together in a system using the EXPANSION IN/OUT connectors. Each of the four program inputs can be individually assigned to the EXPANSION balanced bus
  • Mackie SP1200 | Instruction Manual - Page 19
    mic to either Zone A or to all zones (if multiple SP1200s are used). • For Zone A only, connect a (normally- over the next 2.5 seconds. Note 1: When manually activating the paging mic, there is no timeout so sensitive as to be triggered by ambient sounds around the microphone. Set the PAGING MIC
  • Mackie SP1200 | Instruction Manual - Page 20
    : Each zone or channel must be calibrated individually. 2. Turn off the SP1200, then turn it back on again while pressing and holding the Input 2 to connect a microphone for a speaker in a conference room, or similar sound reinforcement applications. If the local mic is a condenser mic, move the
  • Mackie SP1200 | Instruction Manual - Page 21
    amplifier can provide up to 200 watts into an 8-ohm load. See the "Internal Settings" section on page 13 for instructions on how to reconfigure the amplifiers. Distributed Speaker System When using the SP1200 in a 70V or 100V system, connect the speaker output directly to the distributed system. The
  • Mackie SP1200 | Instruction Manual - Page 22
    to take effect. Using the SPLinker Sound Palette Controller The RS485 connection can also be used to connect the SP1200 to a computer loaded with the Mackie Industrial Technical Support to determine if your control system is compatible with the SP1200. Upgrading the Software From time to time, Mackie
  • Mackie SP1200 | Instruction Manual - Page 23
    4 RIGHT (-) INPUT 4 LEFT (-) GROUND INPUT 3 RIGHT (+) INPUT 3 LEFT (+) INPUT 2 RIGHT (-) INPUT 2 LEFT (-) GROUND INPUT 1 RIGHT (+) INPUT 1 LEFT (+) MACKIE INDUSTRIAL SP1200 BLOCK DIAGRAM (#01.02.01.DF) -15VDC (w/J2 INSTALLED) N/C PAGING MIC (+) INPUT 4 RIGHT (+) INPUT 4 LEFT (+) INPUT 3 RIGHT
  • Mackie SP1200 | Instruction Manual - Page 24
    SP1200 Specifications Power Amplifier Section Continuous Sine Wave Average Output Power, single channel driven: 200 watts into 8 ohms from 20Hz to -52 dBu to +4 dBu Maximum Input Program Inputs: Mic Inputs: +15 dBu +15 dBu Maximum Output at Pre Out +10 dBu SP1200 - 24 SP1200 MUSIC CONTROLLER
  • Mackie SP1200 | Instruction Manual - Page 25
    routine expression of that philosophy. For this reason, any current Mackie Industrial product may differ in some respect SP1200 should require servicing, please follow these instructions: 1. Call Mackie Industrial Tech Support at 1-888-3377404, 8 am to 5 pm PST (Monday-Friday), to verify the problem
  • Mackie SP1200 | Instruction Manual - Page 26
    OFF button to return to normal operation. Press 3 on Power Up: Paging Mic Level Adjustment • Press and hold the Input 3 button while powering up the SP1200. • Release the Input 3 button. The lowest Paging Mic level is indicated on the LED meter. • Use the Up/Down buttons to adjust the lowest Paging
  • Mackie SP1200 | Instruction Manual - Page 27
    that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. Make sure the power is off and the power cord disconnected before removing the top cover to gain access to the inside of the SP1200. JUMPER INSTALLED FOR 115V BROWN
  • Mackie SP1200 | Instruction Manual - Page 28
    SP1200 Music Controller Mackie Industrial 16220 Wood-Red Rd. NE • Woodinville, WA 98072 • USA 888/337-7404 • Outside the U.S.: 425/487-4333 Fax: 425/487-4337 • www.mackieindustrial.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

SP1200 MUSIC CONTROLLER
INPUTS
OFF
3
0
3
6
9
15
30
55
1
2
3
4
ON
OL
STATUS
POWER
COMM PORT
ZONE A
MASTER
VOLUME
PHANTOM
PAGING
GAIN +40dB
MIC/LINE INPUT A
CAUTION:
TO REDUCE THE
RISK OF FIRE REPLACE WITH SAME
TYPE FUSE AND RATING
115V 60Hz FUSE 115/ T4A
120 WATTS
230V 50Hz FUSE 230/ T2A
120 WATTS
1234
12345678
0
I
PROGRAM EQ
1234
ZONE
A
GAIN +40dB
PHANTOM
ON
THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC
"MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE.
COPYRIGHT ©2000 ALL RIGHTS RESERVED
CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA
PARALLEL
INPUTS
G
+
CONTROL
GROUND
ALL CALL
DIRECT
R
OUTPUT
PROGRAM INPUTS
1
2
3
4
PRIORITY
L
HIGH
U
+12
–12
U
+12
–12
LOW
GAIN
+
-
HIGH 12k
FREQ
MID
LOW 80Hz
U
+15
–15
U
+15
–15
U
+15
–15
1K
3K
400
8k
250
HIGH
U
+12
–12
U
+12
–12
LOW
GAIN
+
-
+
-
AMP IN
PRE OUT
PAGING MIC
EXPANSION IN
EXPANSION OUT
AMP ADDRESS
RS485
REMOTE
AMBIENT
MIC
MIC
VOX
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REPLACE WITH THE SAME TYPE FUSE AND RATING.
DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE
UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.
DEBRANCHER AVANT DE REMPLACER LE FUSIBLE
WARNING:
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT
EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
CAUTION
AVIS:
RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR
SERIAL NUMBER
MANUFACTURING DATE
ZONE A
OUTPUT SUITABLE
FOR CLASS 2 WIRING
100/70V/8
+
1
2
3
G
+
A
G
B
12345678
LOCAL
1
2
3
4
REMOTE
1
2
3
4
SP1200
MUSIC CONTROLLER
SP1200 Single-Channel
Program Controller/Amplifier