Magnavox WW-12ESNMAG Window AC Owners Manual

Magnavox WW-12ESNMAG Manual

Magnavox WW-12ESNMAG manual content summary:

  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 1
    OWNER'S MANUAL MODEL: W-08CR W-10CR W-12CR For any service needs, call 1-855-368-8606 Before using this product, please read the instructions carefully and keep for future reference.
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 2
    CONTENTS 1. SAFETY PRECAUTIONS 2 2. IMPORTANT SAFETY INSTRUCTIONS 4 3. AIR CONDITIONER FEATURES 5 4. INSTALLATION INSTRUCTIONS 10 5. CLEANING AND MAINTENANCE 14 6. TROUBLESHOOTING TIPS 15 7. NORMAL OPERATING SOUNDS 17 Read This Manual Inside you will find many helpful tips on how to use and
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 3
    property damage, the following instructions must be followed. Incorrect damage to property. Definition of symbols used in this manual are as shown below. Never do this. ! it must be replaced by the manufacturer or an authorised service centre or a similarly qualified person in order to avoid
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 4
    , turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician. ! 3
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 5
    IMPORTANT SAFETY INSTRUCTIONS NOTE For some models, the power cord for this air conditioner contains a from the power cord. WARNING Electrical Information Be sure the power requirement is adequate for the model you have chosen. This information can be found on the serial plate, which is located on
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 6
    OR ERRORCODES SLEEP MODE CLEAN AIR MODE (only on some models) SET FAN SPEED FOLLOW ME INDICATOR (only on some models) TURNS UNIT ON OR OFF UNIT CONTROL NOTE: The following instructions represent the control panel on the unit, the same instructions can be used for the remote control. TO TURN UNIT
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 7
    Each time the button is pressed, the fan speed mode is shifted. For some models, the fan speed can not be adjusted in HEAT mode. On DRY mode, the such as for room air circulation or to exhaust stale air(only on some models). (Remember to open the vent during this function, but keep it closed during
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 8
    AIR CONDITIONER FEATURES(CONTINUED) TO USE THE ENERGY SAVER FEATURE: Auto Cool Dry Fan ClAeiarn Auto Low Med High Mode Fan Energy Saver FoMlleow On/Off DO THIS: Press the button SLEEP FEATURE: Temp Temp Timer Timer On Off Check Filter Timer Sleep Auto Cool Dry Fan Clean Air Auto
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 9
    Clean Air Auto Low Med High CLEAN AIR FEATURE: (only on some models) Temp Temp NOTE:(CHECK FILTER button) This feature is a reminder to -Unplug the unit and plug it back in. lf error repeats, call for service. NOTE: is displayed as shown in the left diagram. HS--Electric heating sensor error
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 10
    the other, press and hold the LEFT and RIGHT TEMP/TIMER buttons at the same time, for 3 seconds. Fresh Air Vent Control(on 10000~12000Btu/h models): The Fresh Air Vent allows the air conditioner to: 1. Recirculate inside air - Vent Closed ( See Fig.A) 2. Draw f resh air i nto the r oom- Vent Open
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 11
    removal. The rear of the unit must be outdoors, not inside a building or garage. Model 5000~8000Btu/h Size 14 (35.6cm) 10000~12000Btu/h 15-1/2 (39.4cm) Table 1 NOTE: Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter or
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 12
    Fig.F Fig.G C: Align the hole in the top rail with those in the top of the unit as shown in Fig.F ,, D: Secure the top rail to the unit with the 3/8 Screws as shown in Fig.G. NOTE: For safety reasons, all four(4) screws MUST be securely fastened. HOW TO INSTALL NOTE: Top ,r,ail and Sliding Panels
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 13
    INSIDE OUTSIDE Wooden Windows Fig.4 2 Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig.4). Carefully close the window behind the top rail of the unit. Fig.5 Fig.6 3 Extend the side
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 14
    Fig.8 FOAM SEAL 6 To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 1/2" (12.7mm) screw as shown(Fig.8). 7 Cut Window sash seal foam and insert it in the space between the upper and lower sashes (Fig.9). Fig.9 SASH Storm window frame or other obstruction. 1-1/2"min
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 15
    air conditioner. Winter Storage If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton. 14
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 16
    service, review this list. It may save you time and expense. This list includes common problems that may not be the result of defective workman-ship or materials in this appliance. Troubleshooting section Problem (on some models only) on instructed on the 'CARE AND CLEANING SECTION' of this manual
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 17
    Remote control 'FOLLOW ME' mode deactivates prematurely (on some models only) Room is too cold Solution - A dirty air filter may be obstructing the cool air. Clean the filter as instructed on the 'CARE AND CLEANING SECTION' of this manual. - In cases where the outside temperature may be extremely
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 18
    incorrect installation. Pinging or Switching Sound Droplets of water hitting condenser during normal operation may cause pinging or switching sounds. All the illustrations in this manual are for explanation purpose only. Your air conditioner may appear t 17
  • Magnavox WW-12ESNMAG | Window AC Owners Manual - Page 19
    The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. MAGNAVOX and SMART. VERY SMART are registered trademarks of Koninklijke Philips N.V. and are used under license from Koninklijke Philips N.V.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

Before using this product,
please read the instructions
carefully and keep for future reference.
MODEL: W-08CR
W-10CR
W-12CR
For any service needs, call 1-855-368-8606