    ELECTRIC DRYER INSTALLATION INSTRUCTIONS Table of Contents DRYER SAFETY 2 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 LOCATION REQUIREMENTS 4 ELECTRICAL REQUIREMENTS 5 INSTALL LEVELING LEGS 6 ELECTRICAL INSTALLATION 7 Power Supply Cord Connection 8 Direct Wire Connection 10 VENTING 12
  • Maytag MED8000AW | Installation Guide - Page 2
    DRYER SAFETY IMPORTANT: When discarding or storing your old clothes dryer, remove the door. 2
  • Maytag MED8000AW | Installation Guide - Page 3
    mm) or hex-head socket wrench "Y" connector Parts package is located in dryer drum. Check that all parts are included. NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit. Parts needed: (Not supplied with dryer) ■■Vent clamps ■■Vent elbows and vent work
  • Maytag MED8000AW | Installation Guide - Page 4
    ■■Floor must support dryer weight of 200 lbs. (90.7 kg). Also consider weight of companion appliance. ■■Cold water faucets located within 4 ft. (1.2 m) of the water fill valves, and water pressure of 20 - 120 psi (138 - 827 kPa). You may use the water supply for your washer using the "Y" connector
  • Maytag MED8000AW | Installation Guide - Page 5
    Service" section in your "Use and Care Guide." ■■Special provisions must be made in mobile homes to introduce outside air into dryer instructions provided for it here. ■■This dryer used when the appliance is installed in supply cord kit marked for use with clothes dryers. The kit should contain:
  • Maytag MED8000AW | Installation Guide - Page 6
    , use a wrench to finish turning legs until diamond marking is no longer visible. Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the
  • Maytag MED8000AW | Installation Guide - Page 7
    ELECTRIC INSTALLATION For power supply cord installations: For direct wire installations: Before you start: disconnect power. 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R). Go to Power Supply Cord Connection. Power supply cord 3-wire receptacle (NEMA
  • Maytag MED8000AW | Installation Guide - Page 8
    . Be sure that the wire insulation on the power supply cord is inside the strain relief. The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position. Do not further tighten strain relief screws at this point. If your outlet looks like this: Power supply cord
  • Maytag MED8000AW | Installation Guide - Page 9
    neutral wire B C Connect remaining wires under outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Venting Requirements". 3-Wire Power Supply Cord Connection Use where local codes
  • Maytag MED8000AW | Installation Guide - Page 10
    . 1. Prepare your 4-wire cable for direct connection 31 (89 ⁄2" mm) (251"mm) (127 5" mm) Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 5" (127 mm) of outer covering from end of cable, leaving bare ground wire at 5" (127 mm). Cut 11/2" (38
  • Maytag MED8000AW | Installation Guide - Page 11
    hook facing right. Squeeze hooked end together. Tighten screw. 4. Connect remaining wires (893m½m" ) Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire
  • Maytag MED8000AW | Installation Guide - Page 12
    wire (G) under the green external ground conductor screw (A) to an adequate ground. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Venting Requirements." VENTING Venting Requirements 2. Connect neutral ground wire and
  • Maytag MED8000AW | Installation Guide - Page 13
    only if accessible to clean) ■■ Must be fully extended and supported in final dryer location. ■■ Remove excess to avoid sagging and kinking that Replace plastic or metal foil vents with rigid metal or flexible metal vents. Review "Vent System Chart" and if necessary, modify existing vent system to
  • Maytag MED8000AW | Installation Guide - Page 14
    metal 35 ft. (10.7 m) 29 ft. (8.8 m) 4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m) NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Install Vent System 1. Install exhaust hood 12" min. (305 mm) 12" min
  • Maytag MED8000AW | Installation Guide - Page 15
    STEAM MODEL ONLY) For non-steam models, skip to "Connect Vent." The dryer must be connected to the cold water faucet using the new inlet hoses (not couplings 1. Turn cold water off, remove hose, and replace rubber washer Using pliers, tighten the couplings with additional two-thirds turn. NOTE:
  • Maytag MED8000AW | Installation Guide - Page 16
    VENT 1. Connect vent to exhaust outlet Remove protective cap from water inlet valve. Attach other end of long hose to fill valve at bottom of dryer back panel. Screw on coupling by hand until it is seated on fill valve connector. Using pliers, tighten the couplings an additional two-thirds turn
  • Maytag MED8000AW | Installation Guide - Page 17
    will reduce product performance. Excessive scale buildup may lead to the need for certain part replacement or repair. q Select a Time Dry heated cycle, and start dryer. Do not select Air Only Temperature setting. If dryer will not start, check the following: • Controls are set in a running or "On
  • Maytag MED8000AW | Installation Guide - Page 18
    REVERSAL (OPTIONAL) The following instructions are for models with a round and square-shaped doors. Tools needed: 2. Move the door strike Min. 8" long TORX® † T25 screwdriver #2 Phillips screwdriver Reverse door swing round-shaped door - single handle 1. Remove door from dryer Using a TORX T25
  • Maytag MED8000AW | Installation Guide - Page 19
    4. Remove outer window assembly from trim ring 5. Reverse outer window assembly Handle Fig. A Fig. A Fig. B Using a Phillips screwdriver, remove the 2 screws from the outer window retainer and rotate the outer window assembly clockwise until the square notches line up with the 4 tabs on the
  • Maytag MED8000AW | Installation Guide - Page 20
    6. Rotate and reassemble outer window assembly to trim ring Bottom of door 7. Remove hinge and latch Latch Notches Fig. A Hinge Using a TORX® T25 screwdriver, remove the 3 TORX screws securing the latch plate and latch backing plate and the 5 screws holding the hinge assembly in place. 8. 
  • Maytag MED8000AW | Installation Guide - Page 21
    towel or other non-scratch surface. Reinstall the 4 screws in the holes. 2. Move the door strike Using a TORX® T25 screwdriver, remove the 4 screws on the dryer. Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Secure in place with the 4 TORX T25
  • Maytag MED8000AW | Installation Guide - Page 22
    3. Remove inner door from outer door 5. Reinstall hinge and latch on opposite sides Position the door with the inside of the door facing up. Using a Phillips screwdriver, remove the 10 screws securing the inner door to the outer door. Lift off the inner door and set aside. 4. Remove hinge and
  • Maytag MED8000AW | Installation Guide - Page 23
    the 4 screws above and below the door strike and set aside for later use. Rotate the strike 180° and attach to the opposite side of dryer door frame, as shown. 3. Remove inner door from outer door Release tab Release tab Using a TORX T25 screwdriver, remove the 4 screws securing the door hinge
  • Maytag MED8000AW | Installation Guide - Page 24
    Position the inner door on the outer door assembly. Using a Phillips screwdriver, secure with the 13 screws removed earlier. 7. Reattach door to dryer Latch Latch Using a TORX T25 screwdriver, reinstall the latch plate and hinge assembly on the opposite sides from which they were removed. Using
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

W10558997A
W10558999A - SP
Table of Contents
DRYER SAFETY
.........................................................................
2
INSTALLATION REQUIREMENTS
.............................................
3
Tools and Parts
......................................................................
3
LOCATION REQUIREMENTS
....................................................
4
ELECTRICAL REQUIREMENTS
................................................
5
INSTALL LEVELING LEGS
.........................................................
6
ELECTRICAL INSTALLATION
...................................................
7
Power Supply Cord Connection
...........................................
8
Direct Wire Connection
.......................................................
10
VENTING
...................................................................................
12
Venting Requirements
.........................................................
12
Plan Vent System
.................................................................
13
Install Vent System
..............................................................
14
CONNECT INLET HOSE (STEAM MODEL ONLY)
..................
15
CONNECT VENT
......................................................................
16
LEVEL DRYER
..........................................................................
17
COMPLETE INSTALLATION CHECKLIST
..............................
17
DOOR REVERSAL (OPTIONAL)
..............................................
18
ELECTRIC DRYER INSTALLATION INSTRUCTIONS
INSTALLATION NOTES
Date of purchase:
_________________________________
Date of installation:
_______________________________
Installer:
________________________________________
Model number:
___________________________________
Serial number:
___________________________________
Para una version de estas instrucciones en espaƱol, visite www.Whirlpool.com