Maytag MEDB850WQ Dimension Guide
Maytag MEDB850WQ - Bravos 7.3 cu. Ft. Electric Dryer Manual
UPC - 883049179254
View all Maytag MEDB850WQ manuals
Add to My Manuals
Save this manual to your list of manuals |
Maytag MEDB850WQ manual content summary:
- Maytag MEDB850WQ | Dimension Guide - Page 1
Electric Dryer PRODUCT MODEL NUMBERS MEDB200V, MEDB400V, MEDB700V, MEDB800V, MEDB850W Dryer with Extended back view: Dryer with Flat back view: Back view: Bottom view: Recommended Installation Spacing: NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for - Maytag MEDB850WQ | Dimension Guide - Page 2
/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside
Electric Dryer
PRODUCT MODEL NUMBERS
Dryer with Extended back view:
Dryer with Flat back view:
Back view:
Recommended Installation Spacing:
W10388775
06/2011
MEDB200V, MEDB400V, MEDB700V,
MEDB800V, MEDB850W
Bottom view:
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with
tested spacing of 0” (0 mm) clearance on sides and rear.
■
Additional spacing should be considered for ease of
installation and servicing.
■
Additional clearances might be required for wall, door,
and floor moldings.
■
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilitation openings are
acceptable.
■
Companion appliance spacing should also be considered.
NOTE:
Most installations require a minimum of 5" (127 mm)
clearance behind dryer for exhaust vent with elbow. See
“Venting Requirements.”