Maytag MGDB850WR Dimension Guide
Maytag MGDB850WR - Bravos 7.3 cu. Ft. Gas Dryer Manual
UPC - 883049179322
View all Maytag MGDB850WR manuals
Add to My Manuals
Save this manual to your list of manuals |
Maytag MGDB850WR manual content summary:
- Maytag MGDB850WR | Dimension Guide - Page 1
Gas Dryer PRODUCT MODEL NUMBERS MGDB200V, MGDB400V, MGDB700V, MGDB800V, MGDB850W Dryer with extended back: Dryer with flat back: Back view: Bottom view: Recommended Installation Spacing: NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with - Maytag MGDB850WR | Dimension Guide - Page 2
gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas best 90° turns as possible. Maytag Vent System Chart Number Dimensions are for planning purposes only. For complete details, see Installation Instructions
Gas Dryer
PRODUCT MODEL NUMBERS
W10388777
06/2011
MGDB200V, MGDB400V, MGDB700V,
MGDB800V, MGDB850W
NOTE:
Most installations require a
minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with
elbow. See “Venting Requirements”.
Dryer with extended back:
Dryer with flat back
:
Back view:
Bottom view:
Recommended Installation Spacing:
Spacing for recessed area or closet installation
All dimensions show recommended spacing allowed, with tested spacing of 0" (0 mm) clearance
on sides and rear.
■
Additional spacing should be considered for ease of installation and servicing.
■
Additional clearances might be required for wall, door, and floor moldings.
■
Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
■
For closet installation, with a door, minimum ventilation openings in the top and bottom of the
door are required. Louvered doors with equivalent ventilitation openings are acceptable.
■
Companion appliance spacing should also be considered.