Maytag MHWE201YW Dimension Guide

Maytag MHWE201YW Manual

Maytag MHWE201YW manual content summary:

  • Maytag MHWE201YW | Dimension Guide - Page 1
    PRODUCT MODEL NUMBERS MHWE201Y, MHWE251Y, MHWE301Y Washer Washer Dimensions: 501/4" (1276 mm) 27" (686 mm) 36" (914 mm) 301/2" (775 mm) Recessed area or closet installation without pedestal Undercounter installation washer only: 2" (50 mm) 36" min. (914 mm) Cabinet installation: 7" (178
  • Maytag MHWE201YW | Dimension Guide - Page 2
    ; install no higher than 96" (2.4 m) from bottom of washer. Floor drain system 3208" (76120 mm) 41/2" (113 mm) See requirements for floor standpipe drain system. Floor drain system requires a Siphon Break Kit (Part Number 285834), 2 Connector Kits (Part Number 285835), and an Extension Drain Hose
  • 1
  • 2

PRODUCT MODEL NUMBERS
Washer Dimensions:
Undercounter installation -
washer only:
Cabinet installation:
Recessed or closet installation -
with pedestal
W10408696B
06/2011
MHWE201Y, MHWE251Y,
MHWE301Y
Washer
Recessed area or closet installation -
without pedestal
Recessed or closet installation -
stacked washer and dryer
30
1
/
2
"
(775 mm)
27"
(686 mm)
36"
(914 mm)
50
1
/
4
"
(1276 mm)
48" min.
(1220 mm)
1"
(25 mm)
4"
(102 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
1"
(25 mm)
5
1
/
4
"
(133 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
72"
(1829 mm)
12"
(305 mm)
1"
(25 mm)
1"
(25 mm)
1"
(25 mm)
36" min.
(914 mm)
2"
(50 mm)
1"
(25 mm)
4"
(102 mm)
24
"
min.
(610 mm)
38" min.
(965 mm)
1"
(25 mm)
7"
(178 mm)
1"
(25 mm)
4"
(102 mm)
9"
(229 mm)
1"
(25 mm)
All dimensions show recommended spacing allowed, except for
closet door ventilation openings which are the minimum required.
For each arrangement, consider allowing more space for ease of
installation and servicing, and spacing for companion appliances
and clearances for walls, doors, and floor moldings.
Space must be large enough to allow door to fully open.
Add spacing of 1" (25 mm) on all sides of washer to reduce
noise transfer. If a closet door or louvered door is installed, top
and bottom air openings in door are required.