Operating and Installation Instructions Ventilation System To prevent accidents and machine damage, read these instructions before installation or use. en - US M.-Nr. 10 296 060 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 2
SAFETY INSTRUCTIONS 3 Description of functions 7 Guide to the ventilation system 8 Turning the light on/off 9 Fan control 9 Cleaning and care 10 Grease filters 11 Odor-free filter (active charcoal filter 13 Changing the light bulbs 14 After Sales Service 15 Installation instructions 17 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 3
and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. ~ questions, contact Miele. ~ b) Before servicing or cleaning the appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 4
IMPORTANT SAFETY INSTRUCTIONS ~ d) Before connecting the appliance to the power supply described in the enclosed "Installation diagram" and in the "Cleaning and care" section of this manual. Under no circumstances should any other parts of the casing be opened. Tampering with electrical connections - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 5
IMPORTANT SAFETY INSTRUCTIONS ,WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: ~ a) SMOTHER FLAMES with a close fitting lid, - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 6
IMPORTANT SAFETY INSTRUCTIONS Installation ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR a cooktop and the bottom of the hood given in the "Appliance dimensions" section of this manual. If local building codes require a greater safety distance, follow their requirement. If there is more - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 7
Description of functions The ventilation system can be operated: Air extraction Recirculation mode The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 8
Guide to the ventilation system 8 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 9
Guide to the ventilation system a Control panel b Overhead lighting c Odor-free filter (active charcoal filter) Optional accessory for recirculation mode d Cover for the odor-free filter - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 10
, acids or chlorides, - abrasive cleaning agents e.g. powder or cream cleansers, Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". - abrasive sponges, e.g. pot scourers or sponges which have been previously used with abrasive cleaning - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 11
Cleaning and care Special instructions for appliances with a colored (RAL) housing. It is very difficult to clean this type of surface without causing minor marks on the surface material. This - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 12
Cleaning and care Cleaning the filter ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use the pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. They could destroy the filter. ^ In a dishwasher: place - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 13
Cleaning and care Odor-free filter (active charcoal filter) For recirculation mode an odor-free filter must be used in addition to the grease filter. The odor-free filter is designed to absorb cooking odors. It is inserted above the grease filter. ^ Remove the odor-free filter from the packaging. - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 14
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands. Do not attempt to change the bulbs until they have had - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 15
appliance. These are shown on the data plate which is visible when the grease filter are removed. MieleCare (USA only) MieleCare, our Extended Service Contract program, gives you the assurance of knowing that your appliance investment is covered by 5 years of worry free ownership. MieleCare is the - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 16
16 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 17
" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 18
Caring for the environment Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. ,DANGER Ensure that any plastic wrappings, bags, etc., are disposed of safely and kept - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 19
Appliance dimensions DA 1160 B = 23 9/16" (598 mm) DA 1180 B = 29 15/16" (760 mm) Exhaust connection - 5" (125 mm) diameter - 6" (150 mm) diameter 19 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 20
Appliance dimensions Distance between cooktop and hood (S) Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Minimum - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 21
the hood and they have different minimum safety distances always select the greater distance. See "Important Safety Instructions" for further information.Also see the "Important Safety Instructions" section. - To ensure free access to work under the ventilation hood, a distance of a minimum of 26 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 22
information in the "Appliance Dimensions" and " Important Safety Instruction" chapters. This is especially crucial when using the position depends on the operating mode. In air extraction mode, it guides the air outside through an opening at the back of the casing. In air recirculation mode, - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 23
Installation Under-cabinet installation Several holes for fastening the device under a cabinet are provided in the top of the casing. ^ For operation in recirculation mode, cover the opening at the back with the sticker. The sticker comes with the odor-free filter which is available as an optional - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 24
anchors. ,The screws and dowels are suitable for solid brick walls. For other types of walls, use appropriate materials. Make sure that the wall can support the weight. ^ Lift the hood up under the cabinet and feed the power cord through the respective hole in the bottom of the cabinet. ^ From - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 25
Installation ^ Remove the overhead lights. ^ Fasten the wall anchors to the wall using the dowels and screws provided. ^ Slightly loosen the light fastening screw. ^ Slide the screw and the light down. ^ Fasten the screw again. ^ Turn the light counterclockwise and pull it out. 25 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 26
Installation For air extraction mode: ^ Attach the hood to the wall anchors. ^ For an C 6" (150 mm) exhaust duct, use a pointed knife to cut off the exhaust collar where it tapers. For an C 5" (125 mm) exhaust duct, use the collar as is. ^ Tighten the two screws at the left and the right on the - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 27
into the exhaust opening and secure it by turning it clockwise. ^ For further exhaust ducting see "Exhaust ducting". Observe the instructions in "Important safety instructions" and "Electrical connection". ^ Plug the power cord into the power outlet. ^ To carry out a function test, turn the fan on - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 28
the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele's Technical Service Department. Grounding Instructions This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 29
or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork. Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of personal injury. Follow all local building codes when installing the hood. Use smooth or flexible pipework made from approved - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 30
Exhaust ducting - If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 31
Condensate trap (optional accessory) Exhaust ducting In addition to appropriate insulation of the exhaust ducting, we recommend installing a condensate trap to collect and evaporate any condensation which may develop. This is available for ducts C 5" ( 125 mm) or C 6" ( 150 mm). When installing a - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 32
Technical data DA 1160, DA 1180 Maximum load 380 W Fan motor 2 x 140 W Overhead lights 2 x 50 W Voltage 120 V Frequency 60 Hz Fuse rating 15 A Length of the power cord 2.5 ft (0.75 m) Weight DA 1160 24.7 lbs (11.2 kg) DA 1180 28.4 lbs (12.9 kg) Required for recirculation mode: 1 x odor-free - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 33
33 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 34
34 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 35
35 - Miele DA 1180 AM | Operating instructions/Installation instructions - Page 36
DA 1160 DA 1180 en - US M.-Nr. 10 296 060 / 00
Operating and Installation Instructions
Ventilation System
To prevent accidents and machine damage, read these instructions
before
installation or use.
M.-Nr. 10 296 060