Miele Dynamic U1 Cat & Dog Product Manual

Miele Dynamic U1 Cat & Dog Manual

Miele Dynamic U1 Cat & Dog manual content summary:

  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 1
    Operating Instructions Upright Vacuum Cleaner Dynamic U1 HS08 en - US M.-Nr. 10 098 300
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 2
    , or FilterBags with a cardboard retaining plate can lead to serious damage to the vacuum cleaner and may void the warranty, just as with the use of FilterBags without the "Original Miele" logo. The "Original Miele" Logo will appear on the packaging or directly on the FilterBag. Purchasing new
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 3
    Guide to the vacuum cleaner IMPORTANT SAFETY INSTRUCTIONS Before the first use Included accessories Use Power cord 10 Rewinding the power cord 10 Release the vacuum cleaner 10 Turning the vacuum cleaner On/Off 10 "Automatic" setting 11 Vacuum exhaust filters 16 Service indicator with reset
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 4
    Guide to the vacuum cleaner The illustration shows the vacuum cleaner with all available options. Options vary depending on model. 4
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 5
    Guide to the vacuum cleaner a Hand piece b On/Off switch c Carpet/Floor Powerbrush selector d Power cord e Control panel f FilterBag g Dust compartment lid release h Airflow indicator i Headlight * j Powerbrush k Exhaust filter compartment l Exhaust filter * m Foot pedal to recline vacuum n
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 6
    should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WARNING- To reduce the risk of fire, electric shock or injury: Before using ~ Check the voltage rating of the vacuum cleaner before connecting the power cord to an electrical outlet. The
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 7
    INSTRUCTIONS Use ~ Do not use on people or animals. ~ Do not use outdoors or on wet surfaces. Only dry surfaces should be vacuumed. ~ Use only as described in this manual with Miele recommended accessories. ~ This appliance is intended for household use only. ~ Do not allow the vacuum cleaner
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 8
    be replaced with a genuine Miele cord by Technical Service. Disposing of an old appliance ~ Before discarding an old vacuum cleaner, please cut off the power cord and render the plug useless. Ensure the appliance presents no danger to children while being stored for disposal. SAVE THESE INSTRUCTIONS
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 9
    on the fold-out pages at the end of these operating instructions. Before the first use Assembly (see fig. 1) ^ Put the vacuum cleaner in an upright position. ^ Push the handle down into the body of the vacuum cleaner until it engages (see illustration). Activating the exhaust filter change indicator
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 10
    vacuum cleaner to a comfortable position. Turning the vacuum cleaner On/Off (see fig. 13) Always follow the flooring manufacturer's cleaning and care instructions. groove of the plug (see insert). Plug in the vacuum cleaner (see fig. 11) ^ Guide the power cord through the notch at the side and over
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 11
    +/- controls) If the "Automatic" setting is selected, the vacuum cleaner will automatically adjust the suction power level to suit the surface being cleaned. d Blockage protection indicator ^ Press the "Automatic" button. e Service indicator (reset button) The button lights yellow. f "Carpet
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 12
    vacuum in an upright position. ^ Press the release button on the telescopic wand and pull the vacuum hose handle upwards. ^ To increase the stability of the vacuum cleaner, slip the elbow over the vacuum hose so it engages. For regular vacuuming 's cleaning and care instructions. The Powerbrush is
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 13
    body of the vacuum cleaner is placed into the full upright position. ^ For best results, move the Powerbrush slowly back and forth over the area you wish to clean. Maintenance and care ,Turn off and unplug the vacuum cleaner before performing any maintenance work. The Miele filter system consists
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 14
    are supplied with every box of Miele filter bags. If you would like to purchase additional Miele filters separately, contact your vacuum dealer or Miele, please quote the model number of your Miele vacuum cleaner to ensure correct parts are ordered. These parts are also available to order from
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 15
    fig. 29) ^ Place the body of the vacuum cleaner into the full upright position. ^ Lift the release button for the dust that automatically closes to prevent dust from escaping when the bag is removed. ^ Open the dust compartment lid. ^ box of Miele FilterBags, you should change this exhaust filter. A
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 16
    lid. If you wish to use an Air Clean filter see "Exchanging exhaust filters". Exchanging exhaust filters Depending on the model, your vacuum cleaner will use one of the following standard exhaust filters (see fig. 2): a AirClean b Active AirClean 30 (black) c HEPA AirClean (white) If you wish
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 17
    components. To do this, the vacuum cleaner must be turned on. ^ Press the reset button [. The service indicator will go out and be Click the vacuum cleaner into the full upright position. ^ Press the release button on the telescopic wand and remove the handle from the suction hose ^ Guide the swivel
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 18
    "§" Thermo indicator lights red. A temperature sensor will turn off the vacuum cleaner if it becomes too warm. This problem can occur if, for example, an object is blocking the suction tube or the FilterBags pores have become clogged with fine dust. The cause could also be a heavily soiled exhaust
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 19
    the vacuum cleaner. You can order these and many other products via the Miele website. Attach the desired accessory onto the handle of the vacuum hose vacuuming large areas of hard flooring and tight spaces. Other accessories Always follow the flooring manufacturer's cleaning and care instructions.
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 20
    Caring for the environment Disposal of the packing material The cardboard box and packaging protect the vacuum cleaner during shipping. These materials are recyclable. Please recycle. Ensure that any plastic wrappings, bags etc. are disposed of safely and kept out of the reach of children. Danger of
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 21
    free of charge to the consumer (both parts and labor) by an authorized Miele service agent. c. The warranty period for vacuum cleaners (excepting the S8990 and RX1 Scout), and all accessories, excluding vacuum cleaner motors, power head motors, and vacuum cleaner casings (body), is one (1) year from
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 22
    22
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 23
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 24
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 25
    25
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 26
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 27
  • Miele Dynamic U1 Cat & Dog | Product Manual - Page 28
    Fax: 609-419-4298 www.mieleusa.com Technical Service & Support Nationwide Phone: 800-999-1360 Fax: 888-586-8056 [email protected] Canada Importer Miele Limited Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8 www.miele.ca Customer Care Centre Phone: 800-565-6435
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Operating Instructions
Upright Vacuum Cleaner
Dynamic U1
M.-Nr. 10 098 300
en - US
HS08