    Solutions, Ltd. 2002-2011 Updated on November 03, 2011 This file contains information about NEC projector control commands. Model Name GT60 : GT5000/GT6000 Series GT50 : GT1150/GT2150 Series HT : HT1000/HT1100 Series HT10 : HT410/HT510 Series LT180 LT180 LT30 : LT25/
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 2
    Descriptions 6. Table of Response Error Codes 1. Projector Control NEC projectors make use of control commands that control the a USB cable. * Note that a connection method using the supplied USB cable is not supported for the LT220/240/260. * The serial cable, LAN card and LAN cable are
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 3
    [P350X/P350W/P420X Series] STANDBY MODE: "POWER-SAVING" Control Command POWER ON Yes: Supported No: Not supported Serial Wired Wireless port LAN port LAN unit Yes No No 3. Interface Conditions Serial connection The communications method conforms to the RS-232C standard.
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 4
    Yes No No No Yes No PA600X/PA550W/PA500U/PA500X Yes No No No Yes Yes PX750U Yes No No No Yes Yes Yes: Supported No: Not Supported * A USB cable is supplied as standard with the MT860/1060/1065/1075. * The GT5000/6000 does not come with a USB cable. * Note that a connection
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 5
    unit Yes No No [PA600X/PA550W/PA500U/PA500X Series] STANDBY MODE: "NETWORK STANDBY" Serial Control Command port POWER ON Yes Yes: Supported No: Not supported Wired LAN port Yes Wireless LAN unit Yes Baud rate: Data length: Parity bit: Stop bits: Communications mode: 38400 bps (NP600
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 6
    [ GT/LT80/MT/NP1000/VT (except VT70/VT80/VT90)/NP3150/NP905/NP600/NP4000/NP3250/NP610/NP2200/NP216/M300/P420/U300/V300 ] The PC CONTROL connector is a D-SUB 9-pin connector. 1 2 To TxD of PC 3 To RxD of PC 4 5 To GND of PC 6 7 To CTS of PC 8 To RTS of PC 9 4. Communication Frame On the LT/MT/SX/
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 7
    This is an identification data assigned to each command. Command : This sets an identification data assigned to each command to send it. ( See each command description.) Response : This returns the 6th bit of received ID1 as HIGH. For ACK it sends the 8th bit back as LOW (recognized); for NAK it
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 8
    * When the controller is connected with the projector on a one-to-one basis Broadcast notification is recommended. * When the controller is connected with multiple projectors To control a certain projector, use "individual notification". For all others "broadcast notification" is recommended.
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 9
    ) Power On Command: 02H 00H FFH F0H 00H CKS NAK: A2H 00H 01H 20H 02H DATA01 DATA02 CKS Data Contents DATA01 Error types 00H : Not supported 01H : Parameter error 02H : Operation mode error 03H : Gain-related error 04H : Logo transfer error DATA02 Error description * When not
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 10
    This conforms to the USB1.1 standard. Transfer speed: All speeds (supported) Endpoint: Control transfer Endpoint 0 Device class: HID class (Ver1 LAN card that is used. - For information on supported LAN cards, visit: Global: http://www.nec-pj.com/ [Port Number] The TCP port number used is "7142".
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 11
    4. List of Commands * Example for command Command name Example 006. RUNNING SENSE 007. COMMON DATA REQUEST 009. ERROR STATUS REQUEST 015. POWER ON 016. POWER OFF 018. INPUT SW CHANGE 020. PICTURE MUTE ON 021. PICTURE MUTE OFF 022. SOUND MUTE ON 023. SOUND MUTE OFF 024.
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 12
    05 : MT860 06 : WT600/WT610/WT615 07 : GT5000 08 : LT240K/LT260K 09 : GT6000 10 : HT1100 11 : VT770 12: HT410/HT510 (HT10 Series) 13 : LT245/LT265 14 : LT280/LT380 15 : LT180 16 : VT37/VT47/VT470/VT57/VT570/VT575/VT670/VT676 (VT70 series) 17 : VT48/VT480/VT580 (VT80 Series) 18 : NP1000/NP2000 (
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 13
    available depending on model's version - Not Supported Availability by Model (CURRENT MODELS) Command Name 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 006. RUNNING SENSE
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 14
    Command Name 006. RUNNING SENSE 007. COMMON DATA REQUEST 009. ERROR STATUS REQUEST 015. POWER ON 016. POWER OFF 018. INPUT SW CHANGE 020. PICTURE MUTE ON 021. PICTURE MUTE OFF 022. SOUND MUTE ON 023. SOUND MUTE OFF 024. ONSCREEN MUTE ON 025. ONSCREEN MUTE OFF 030. GAIN ADJUST 030-2. VOLUME ADJUST
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 15
    In case of NP216 series In case of V300 series In case of VT series In case of NP600 series In case of NP610 series In case of NP2200 series In case of M300 series In case of P420 series In case of GT series In case of HT series In case of WT series In case of HT10 series In case of LT180 series In
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 16
    DATA01 Status of operation Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution Bit 6: Selecting signal processing 0 = No execution (Normal condition) 1 = During execution Bit 5: Cooling processing 0 = No execution (Normal condition) 1 = During execution Bit 4:
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 17
    00H: Idling 01H: Power On DATA05 Cooling processing 00H: No execution (Normal condition) 01H: During execution DATA06 Indication signal number (Entry list number - 1) 0 .. 199 DATA07 Type 1 of input terminal to be selected (!) 01H : 1 02H : 2 03H : 3 04H : 4 05H : 5 DATA08 Type 2 of input terminal
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 18
    (!2) 00H : OFF 01H : ON FFH : Not Supported DATA33 Test pattern display 1 00H : No display (Normal * * * * * - - * * * * * * * - * * - - * : Supported - : Not supported *1: Only LT240K/260K V300 Pattern ID Pattern Name PA600 PX750 01H Cross Hatch * * 02H Gray Bars * *
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 19
    DATA68 Selecting signal processing 00H : No execution (Normal condition) 01H : During execution DATA69 Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling (Error occurrence) Other than above: (nondisclosure) Internal use of code during a state transition period DATA70 .. 71
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 20
    Data01 01H 01H 01H 01H 02H 02H 02H 02H 02H 02H 03H 03H 03H 04H 04H 04H 04H 05H 05H 06H 06H 08H 08H 08H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 10H 11H 11H 11H 11H 11H 11H 11H 11H 12H 12H 12H 12H 12H 12H 12H 13H 13H 13H 13H 13H 13H 13H 14H 14H 15H 15H 15H 15H 16H 16H 16H 17H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 21
    DATA72 PC Card insertion 00H : Not inserted 01H : Inserted DATA73 USB Mouse connection 00H : Not connected 01H : Connected DATA74 Entry list type 01H : Default 02H : User DATA75 .. 82 Reserved DATA83 On-screen mute 00H : OFF 01H : ON DATA84 Reserved DATA85 Indicate Contents 00H = Picture
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 22
    009. ERROR STATUS REQUEST Function: This command acquires the error information occurring with the projector. Command: 00H 88H 00H 00H 00H 88H Response: At the time of a success 20H 88H 01H xxH 0CH DATA01 .. DATA12 CKS (*1) (*2) (*3) Data Portion Contents The various bits are normal is "0"
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 23
    Supplement: (!) LT/LT80/HT: "None" 015. POWER ON Function: This command switches on the main power of the projector. Command: 02H 00H 00H 00H 00H 02H Response: At the time of a success 22H 00H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 00H 01H xxH 02H DATA01 DATA02
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 24
    (!): The MT860/LT280 does not support a DVI connector. (!!) HT1000 (!!!) HT410/HT510/HT1100 (!!!!) VT770 support Component and Viewer (!1) VT470/VT470JY/VT570/VT670/VT575/VT676/VT480/VT580 (!2) VT595/VT695/VT700/NP300/NP400/NP500/NP500W/NP600/NP500WS/NP600S (!3) NP62/NP64 only (not
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 25
    Response: At the time of a success 22H 03H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Results 00H : Normal FFH : Error Response: At the time of a failure A2H 03H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * When switch to the Video
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 26
    022. SOUND MUTE ON Function: This command mutes the sound. Command: 02H 12H 00H 00H 00H 14H Response: At the time of a success 22H 12H 01H xxH 00H CKS (*1) (*2) (*3) Response: At the time of a failure A2H 12H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: * Sound mute is
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 27
    of tint *tint increment/decrement brightness contrast color tint sharpness Not supported "LT170","VT60 series","VT70 series","VT80 series", "VT90 series" Not supported "HT410/HT510","LT180/LT25/LT30/LT35" volume Not supported "LT170","VT60 series","VT70 series" (except "VT80 series, VT90 series
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 28
    DATA03 : 00H (direct settings) 01H (increment/decrement) DATA04 : lower data (8bit) DATA05 : upper data (8bit) ex.1) volume direct setting (value = 20) DATA01 : 05H (Volume) DATA02 : 00H ("Volume" only) DATA03 : 00H (direct setting) DATA04 : 14H (lower data : 20 = 0014) DATA05 : 00H (upper data
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 29
    DATA01 .. 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 030-12. IMAGE MODE ADJUST Function: This command
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 30
    DATA04 DATA05 Aspect Ratio 4:3 (Window) Aspect Ratio Normal / Auto (NP600, NP610, NP2200, NP62, NP64, NP216, P420, PA600, U300, V300 Series) Aspect Ratio 1.25:1(5:4) Aspect Ratio Letter Box (PA600, PX750 Series) Aspect Ratio 1.33:1(4:3) Aspect Ratio Wide Zoom (NP600, NP610, NP2200, NP62, NP64,
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 31
    Supplement: (!) Lamp Hour Meter This is the timer for normal lamp mode conversion. Lamp Timer Acquisition Examples DATA83 DATA84 DATA85 DATA86 : Lamp Timer 00H 00H 00H 00H : Total 0 seconds C0H 65H 52H 00H : Total 5400000 seconds/3600 = 1500 hours 00H E4H 57H 00H : Total 5760000 seconds/3600 = 1600
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 32
    2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - value will change to 7200000 seconds Lamp remaining time (in terms of Normal mode values) = (7200000 - 10800) / 3600 = 1997 hour 037-2. LAMP INFORMATION REQUEST 2 Function: This command acquires lamp remaining
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 33
    conversion. (!!) Lamp usage time This is the lamp total usage. It is displayed in the projector's menu. (!!!) NP4000/4001, NP4100/4100W : This function is not supported. 037-7. LAMP INFORMATION REQUEST 4
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 34
    Function: This command acquires the information on the projector lamp. Command: 03H 9BH 00H 00H 03H DATA01 DATA02 DATA03 CKS (*3) Data Portion Contents DATA01 Target 00H : Lamp1 01H : Lamp2 DATA02 Unit(!4) 00H : Second 01H : Reserved 02H : Hour DATA03 Item 00H : Lamp Hour Meter (
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 35
    displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. (!5) NP4000/4001, NP4100/4100W : This function is not supported. 038. LAMP MODE REQUEST Function: This command acquires the setting of the lamp mode of projector. Command: 03H B0H 00H 00H 01H 07H BBH
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 36
    00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 046. WXGA MODE SETTING REQUEST Function: This command acquires the setting of the WXGA Mode of projector. Command: 03H B0H 00H 00H 01H C3H 77H Response: At the time of a
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 37
    description 00H 00H 00H 01H 01H 00H 01H 01H 02H 03H 02H 0DH Error contents Unknown command. This current model does not support this function. Invalid values specified. Specified terminal is unavailable or cannot be selected. Setting not possible. Power Off inhibited. 050. REMOTE KEY
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 38
    Key number DATA01 DATA02 Key name 1 01H 00H POWER 2 02H 00H POWER ON (!!) 3 03H 00H POWER OFF (!!) 4 04H 00H SOURCE (AUTO) (!!) 5 05H 00H AUTO (!) (!!) 6 06H 00H MENU (!!) (!!!) 7 07H 00H UP (!!) (!!!) 8 08H 00H DOWN (!!) (!!!) 9 09H 00H RIGHT (!!) (!!!) 10 0AH 00H LEFT (!!) (!!!) 11 0BH 00H ENTER
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 39
    A2H 0FH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) (!) About AUTO key The MT series model with the built-in image sensor does not support the AUTO key. Use the AUTO (SHORT) key. (!!) HT10 series, LT180, LT30 series, NP40 series and NP4000 series (!!!) VT60 series, VT70 series, VT80
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 40
    Command example: * Sending the AUTO key code 02H 0FH 00H 00H 02H 05H 00H 18H * Sending the AUTO (SHORT) key code 02H 0FH 00H 00H 02H DDH 00H F0H * cycle/toggle volume mute * cycle/toggle picture mute * cycle/toggle picture freeze 02H 0FH 00H 00H 02H DATA01 DATA02 CKS Data Portion Contents DATA01
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 41
    051. CARBON SAVINGS INFORMATION REQUEST Function: This command acquires the Carbon Saving values on the projector. Command: 03H 9AH 00H 00H 01H DATA01 CKS (*3) Data Portion Contents DATA01 Acquirement items 00H : Total Carbon Savings 01H : Carbon Savings during operation Response: At the time
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 42
    DATA01 Target 00H : Use Point on Signal Change 01H : Picture mute during lens shift DATA02 Setting Value 00H : Inactive 01H : Active Response: At the time of a success 22H 21H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*3) Data Portion Contents DATA01 same values as DATA01 of the command
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 43
    DATA09 Current value (Upper ranking 8 bits) DATA10 .. 13 Reserved Response: At the time of a failure A3H 04H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) (!) Acquirement items DATA01 00H 01H 02H 03H 04H 05H 05H 05H 06H 06H 06H 06H 06H 07H 08H 08H 09H 09H 0AH 0BH 0CH 0CH 0DH 0DH 0EH 0EH
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 44
    4CH 4CH 4CH 4CH 4DH 4EH 4EH 4EH 4FH 50H 51H 51H 52H 52H 52H 53H 54H 54H 54H 54H 54H 54H 54H 55H 56H 57H 58H 59H 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5AH 5BH 5CH 5DH 5EH 5FH 5FH 5FH 5FH 5FH 5FH 5FH 60H 61H 61H 61H 62H 62H 62H 63H 63H 63H 63H 63H 63H 64H 64H 64H 64H 64H 64H 65H 65H 65H 65H 65H 65H 66H 07H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 45
    077. MUTE CONTROL Function: This command controls the mute of picture, sound and on-screen. Command: 02H 1AH 00H 00H 02H DATA01 DATA02 CKS (*3) Data Portion Contents DATA01 Setting items 00H : Picture 01H : Sound 02H : On-Screen DATA02 Setting Value 00H : OFF 01H : ON Response: At the time of
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 46
    DATA01 DATA02 DATA03 08H 00H 10H NP4100 08H 01H 10H NP4100W 11H 00H 12H NP64 11H 03H 12H NP43 13H 01H 10H M300X 13H 02H 10H M300W 13H 05H 10H M260X 13H 06H 10H M260W 13H 00H 11H P420X 13H 01H 11H P350X 13H 02H 11H P350W 14H 02H 10H U300X 14H 04H 10H U310W 15H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 47
    Legacy Models 01H 00H 03H MT1060/MT1065 01H 01H 03H MT860 01H 02H 03H MT1075 01H 00H 06H NP1000/NP2000 02H 00H 03H LT240/LT260 02H 01H 03H LT220 02H 02H 03H LT240K/LT260K 02H 00H 05H LT245/LT265 02H 00H 06H LT380 02H 01H 06H LT280 03H 00H 06H VT80 Series 03H 00H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 48
    DATA05 Calendar function 00H : No function 01H or 03H : Timer function, sleep timer function 02H : Sleep timer function DATA06 .. 32 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 078-2. RUNNING STATUS REQUEST Function: This command
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 49
    (*1) (*2) (*4) (*3) 078-3. INPUT STATUS REQUEST Function: This command acquires the status of input signal of the projector. Command: 00H 85H 00H 00H 01H 02H 88H Response: At the time of a success 20H 85H 01H xxH 10H DATA01 .. DATA16 CKS (*1) (*2) (*3) Data Portion Contents DATA01
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 50
    01H : Displaying DATA07 ..08 Reserved DATA09 Indicate Contents 00H = Picture signal displaying 01H = No signal 02H = Viewer displaying 03H = Test pattern displaying 04H = LAN displaying DATA10 .. 16 Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2)
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 51
    02H 00H 02H 03H 04H 06H 07H 08H 09H 0AH 0CH 0DH 0EH 0FH 00H 01H 02H Unknown command The current model does not support this function. Unvalid values specified. Specified terminal is unavailable or cannot be selected. Selected language is not available. Available memory reservation error Operating
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 52
    Function: This command controls the freeze. Command: 01H 98H 00H 00H 01H DATA01 CKS Operation types DATA01: 00H : Reserved 01H : Freeze start 02H : Freeze cancel Response: At the time of a success 21H 98H ID *0H 01H DATA01 CKS Data Portion Contents DATA01 Results 00H : Normal 01H : Error
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 53
    Data Portion Contents DATA01 C5H fixed DATA02 Acquisition Object 00H : MODE 01H : POSITION 02H : SOURCE Response: At the time of a success 23H B0H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents DATA01 C5H fixed DATA02 Acquisition item(Same as DATA02 of the transmit
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 54
    if DATA02 is SOURCE(02H) 00H : OFF 01H : VIDEO 02H : S-VIDEO Response: At the time of a success 23H B1H 01H xxH 03H DATA01 DATA02 DATA03 CKS (*1) (*2) (*3) Data Portion Contents DATA01 00H fixed DATA02 Update target ( Same as DATA02 of the transmit data ) DATA03 Results 00H : Normal 01H :
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 55
    111. AUTO ADJUST EXECUTE2 Function: This command executes the Auto Adjust. Command: 03H BAH 00H 00H 01H 00H BEH Response: At the time of a success 23H BAH 01H xxH 01H 00H CKS (*1) (*2) (*3) Response: At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 305
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 56
    DATA02 DATA03 DATA13 DATA14 03H 08H 00H 10H NP4100 03H 08H 01H 10H NP4100W FFH 11H 00H 12H NP64 FFH 11H 03H 12H NP43 FFH 13H 01H 10H M300X FFH 13H 02H 10H M300W FFH 13H 05H 10H M260X FFH 13H 06H 10H M260W FFH 13H 00H 11H P420X FFH 13H 01H 11H P350X FFH 13H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 57
    Legacy Models 00H 01H 00H 03H MT1060/1065 00H 01H 02H 03H MT860 00H 01H 02H 03H MT1075 00H 01H 00H 06H NP1000/NP2000 00H 02H 00H 03H LT240/LT260 00H 02H 01H 03H LT220 00H 02H 02H 03H LT260K 00H 02H 00H 05H LT245/LT265 00H 02H 00H 06H LT380 00H 02H 01H 06H LT280
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 58
    02H fixed DATA02 Projector Processing Status 00H : Idle 04H : Power On 05H : Cooling 06H : Idle(Error Standby) Other : Not Support Other than above : (nondisclosure) Internal use of code during a state transition period DATA03 Indicate Contents 00H : Picture signal displaying 01H
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 59
    .58 SQZ xAH : COMPONENT(60Hz) xBH : COMPONENT(50Hz) xCH : Un known xDH : NTSC xEH : PAL-M xFH : PAL-N FFH : Not Video Input Other : Not Support DATA07 Picture Mute 00H : OFF 01H : ON DATA08 Sound Mute 00H : OFF 01H : ON DATA09 On-screen mute 00H : OFF 01H : ON DATA10...DATA16
  • NEC NP-PX800X-08ZL | RS232 codes- Projectors - Page 60
    of Response DATA01 DATA02 Error types Error description Error contents 00H 00H Unknown command 00H 01H The current model does not support this function. 01H 00H Unvalid values specified. 01H 01H Specified terminal is unavailable or cannot be selected. 01H 02H Selected language
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

======================================================================
Control Commands for NEC Projector (Basic) Rev 11.03.11a
Copyright (C) NEC Display Solutions, Ltd. 2002-2011
----------------------------------------------------------------------
Updated on November 03, 2011
----------------------------------------------------------------------
This file contains information about NEC projector control commands.
Model Name
GT60
: GT5000/GT6000 Series
GT50
:
GT1150/GT2150 Series
HT
:
HT1000/HT1100 Series
HT10
:
HT410/HT510 Series
LT180
LT180
LT30
: LT25/LT30/LT35 Series
LT
:
LT220/LT240/LT240K/LT260/LT260K/LT245/LT265 Series
LT80
: LT280/LT380 Series
MT70
: MT860/MT1060/MT1065/MT1075 Series
NP60
:
NP40/NP50/NP60 Series
NP62
:
NP41/NP61/NP62 Series
NP1000
: NP1000/NP2000 Series
NP3150
: NP1150/NP2150/NP3150/NP3151W Series
NP4000
:
NP4000/NP4001 Series
NP905
: NP905/NP901W/VT800 Series
NP600
:
NP300/NP400/NP500/NP500W/NP500WS/NP600/NP600S Series
VT
:
VT770 Series
VT70
:
VT37/VT47/VT480/VT57/VT570/VT575/VT670/VT676 Series
VT80
:
VT48/VT480/VT580 Series
VT90
:
VT49/VT490/VT590/VT595/VT695 Series
VT700
:
VT700
WT
:
WT600/WT610/WT615 Series
NP4100
:
NP4100/NP4100W Series
NP3250
: NP1250/NP2250/NP3250/NP3250W Series
NP610
:
NP310/NP410/NP410W/NP510/NP510W/NP510WS/NP610/NP610S Series
NP2200
:
NP1200/NP2200 Series
NP216
:
NP110/NP115/NP215/NP216 Series
NP64
:
NP43/NP64 Series
M300
:
M260X/M260W/M300X/M300W Series
P420
:
P350X/P350W/P420X Series
U300
:
U300X/U310W Series
V300
:
V260/V260X/V300X/V300W Series
PA600
:
PA600X/PA550W/PA500U/PA500X
PX750U
PX750U Series