NEC PN-ME502 External Control Codes

NEC PN-ME502 Manual

NEC PN-ME502 manual content summary:

  • NEC PN-ME502 | External Control Codes - Page 1
    External Control ME series PN-ME432/PN-ME502 /PN-ME552/PN-ME652 R1.0 1/63
  • NEC PN-ME502 | External Control Codes - Page 2
    Contents 1. Overview 4 2. Connection 4 2.1 RS-232C 4 2.2 LAN 4 3. Communication conditions 5 3.1 RS-232C 5 3.2 LAN 5 4. Command format 6 4.1 Header (fixed length) 6 4.1.1 Header Format 6 4.2 Message 8 4.2.1 Get VCP command 8 4.2.1.1 Format and detail of Get VCP command. 8
  • NEC PN-ME502 | External Control Codes - Page 3
    5.2.21 CTL-CA04-03. Input Name of Designated Terminal Read Request 42 5.2.22 CTL-CA04-04. Input Name of Designated Terminal Write Request 43 5.2.23 CTL-CA04-05. Input Name of Designated Terminal Reset Request 44 5.2.24 CTL-CA0B-00. Power Save Mode Read Request 45 5.2.25. CTL-CA0B-01. Power
  • NEC PN-ME502 | External Control Codes - Page 4
    monitor. 2. Connection method 2.1 RS-232C Connector Cable : 9-pin D-sub : クCロroスs(sリinバgー(rスev)ケerーseブ)ルcable Note : See "RS-232C remote control" in the instruction manual. 2.2 LAN Connector Cable : RJ-45 10/100 BASE-T : Category 5 or higher LAN cable Note : See "LAN Control" in the Owner
  • NEC PN-ME502 | External Control Codes - Page 5
    3.2 LAN Communication system Communication layer 7142 (Fixed) TCP For details on various settings, refer to "Network Settings" in the Operating Instructions. Note: ・ The monitor will disconnect after 15 minutes of communication loss. Please reconnect every time you communicate after an interval
  • NEC PN-ME502 | External Control Codes - Page 6
    4. Command format External control commands are roughly classified into two types: VCP and CTL. Each command consists of four parts, Header, Message, Check code, and Delimiter, as shown below. Header Message Check Code Delimiter The content of the message varies depending on the type of command
  • NEC PN-ME502 | External Control Codes - Page 7
    ASCII 'C' (43h): Get VCP command ASCII 'D' (44h): Get VCP command reply ASCII 'E' (45h): Set VCP command ASCII 'F' (46h): Set VCP command reply 6th-7th) Message Length: Defines the command length of the Message, ranging from STX to ETX following the header. This length includes STX and ETX. Byte
  • NEC PN-ME502 | External Control Codes - Page 8
    4.2 Message Header Message Check Code Delimiter The format of Message is determined by the 5th (Message type) of Header, and there are the following 6 types. Get VCP command Get VCP command reply Set VCP command Set VCP command reply CTL command CTL command reply 4.2.1 Get VCP command
  • NEC PN-ME502 | External Control Codes - Page 9
    4.2.2.1. Format and detail fo Get VCP command reply STX Result Hi Lo 1st 2nd-3rd OP Code Page Hi Lo 4th-5th Message OP Code Hi Lo 6th-7th Reserved Hi Lo 8th-9th Max value Current Value ETX MSB ・・・ LSB MSB ・・・ LSB 10th-13th 14th-17th 18th 1st) STX:Start of Message Specify the ASCII code
  • NEC PN-ME502 | External Control Codes - Page 10
    4.2.3. Set VCP command This Message is sent when the controller changes the monitor settings. Notes : For each "OP code page" and "OP code", please refer to "6.VCP command". 4.2.3.1. Format and detail of Set VCP command OP Code STX Page Hi Lo 1st 2nd-3rd Message OP Code Hi Lo 4th-5th Set
  • NEC PN-ME502 | External Control Codes - Page 11
    4.2.4.1. Format and detail of Set VCP command reply. STX Result Hi Lo 1st 2nd-3rd OP Code Page Hi Lo 4th-5th Message OP Code Reserved Hi Lo 6th-7th Hi Lo 8th-9th Max value Requested Setting value ETX MSB ・・・ LSB MSB ・・・ LSB 10th-13th 14th-17th 18th 1st) STX:Start of Message Specify
  • NEC PN-ME502 | External Control Codes - Page 12
    4.2.5. CTL command The format of Message in Commands depends on each command. Notes : Refer to "5.CTL Command" for detail. 4.2.6. CTL command replay The monitor responds to commands received from the controller. The format of Message in Commands depends on each command. Notes : Refer to "5.CTL
  • NEC PN-ME502 | External Control Codes - Page 13
    4.3. Check code Header Message Check Code Delimiter 4.3.1. Check code format and calculation method Check code is the Block Check Code (BCC) from Header to end of Message, excluding SOH. It is calculated by exclusive OR (XOR). Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 SOH D0 Reserved D1
  • NEC PN-ME502 | External Control Codes - Page 14
    5. CTL Command 5.1 CTL Command table The CTL commands supported by this unit are as follows. CTL number CTL-07 CTL-0C CTL-B1 CTL-BE CTL-01D6 CTL-C203-D6 CTL-C03F CTL-C211
  • NEC PN-ME502 | External Control Codes - Page 15
    5.2 Detail of CTL command. This chapter describes the details of the following Message parts for CTL commands. Header Message Check Code Delimiter For Header/Check Code/ Delimiter, refer to "4.Command format". 5.2.1 CTL-07. Get Timing Report and Timing reply This command is used to read the
  • NEC PN-ME502 | External Control Codes - Page 16
    5.2.2 CTL-0C. Save Current Settings This command is used to save adjusted values. When the monitor receives this command, save the current settings in non-volatile memory such as EEPROM. 【Controller → Monitor】 Message Command STX Code '0' 'C' 02h 30h 43h 1st 2nd-3rd ETX ASCII 03h HEX 4th
  • NEC PN-ME502 | External Control Codes - Page 17
    5.2.3 CTL-B1. Self-diagnosis status read This command is used to read the self-diagnostic status. 【Controller → Monitor】 Message Command STX Code 'B' '1' 02h 42h 31h 1st 2nd-3rd ETX ASCII 03h HEX 4th 1st) STX:Start Message Specify the ASCII code 'STX' (02h). 2nd-3rd) Command Code: 'B'-'1'
  • NEC PN-ME502 | External Control Codes - Page 18
    Notes: ・If no error has occurred, responded with '0'-'0'(30h 30h). ・If multiple errors have occurred, multiple error codes are responded. ex)If Temperature abnormality and System error at the same time, ST(0) and ST(1) are specified as follows: ST(0):'A'-'0'(41h 30h) Temperature abnormality (
  • NEC PN-ME502 | External Control Codes - Page 19
    【Monitor→Controller(ACK)】 Message Command STX Reserved Result Code Code Max '0' '2' 'x' 'x' 'D' '6' '0' '0' '0' '0' '0' '4' ASCII 02h 41h 31h xxh xxh 44h 36h 30h 30h 30h 30h 30h 34h HEX 1st 2nd-3rd 4th-5th 6th-9th 10th-13th Message Power status 'x' 'x' 'x' 'x' xxh xxh xxh xxh 14th-
  • NEC PN-ME502 | External Control Codes - Page 20
    2nd-7th) Command Code: 'C'-'2'-'0'-'3'-'D'-'6' (43h, 32h, 30h, 33h, 44h, 36h) 8th-11th) Power status 0'-'0'-'0'-'1' (30h, 30h, 30h, 31h) : Power on 0'-'0'-'0'-'4' (30h, 30h, 30h, 34h) : Power off 12th) ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Message
  • NEC PN-ME502 | External Control Codes - Page 21
    【Monitor→Controller(ACK)】 Command STX Code 'C' '1' '3' 02h 43h 31h 33h 1st 2nd-5th Message FW Revision strings 'F' Data(0) - Data(N) 46h xxh - xxh 6th-xxth ETX ASCII 03h HEX (xx+1)th 1st) STX:Start Message Responds with the ASCII code 'STX' (02h). 2nd-5th) Command Code:
  • NEC PN-ME502 | External Control Codes - Page 22
    6th) ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Message Command STX Code Year Month Day Weekdays 'C' '3' '1' '1' 'x' 'x' 'x' 'x' 'x' 'x' 'x' 'x' ASCII 02h 43h 33h 31h 31h xxh xxh xxh xxh xxh xxh xxh xxh HEX 1st 2nd-5th 6th-7th 8th-9th 10th-
  • NEC PN-ME502 | External Control Codes - Page 23
    '0'-'0' (30h, 30h) : 0 ~ '3'-'B' (33h, 42h) : 59 18th-19th) Reserved Specify the ASCII code '0'-'0' (00h). 20th) ETX: End of Message Responds with the ASCII code 'ETX' (03h). 5.2.9 CTL-C212. Date & Time Write This command is used in order to write the setting of the Date & Time. 【Controller →
  • NEC PN-ME502 | External Control Codes - Page 24
    '0'-'3' (30h, 33h) : Wednesday '0'-'4' (30h, 34h) : Thursday '0'-'5' (30h, 35h) : Friday '0'-'6' (30h, 36h) : Saturday 14th-15th) Hours '0'-'0' (30h, 30h) : 0 ~ '1'-'7' (31h, 37h) : 23 16th-17th) Minutes '0'-'0' (30h, 30h) : 0 ~ '3'-'B' (33h, 42h) : 59 18th-19th) Reserved Specify the ASCII code
  • NEC PN-ME502 | External Control Codes - Page 25
    12th-13th) Day '0'-'1' (30h, 30h) : 1 ~ '1'-'F' (31h, 46h) : 31 14th-15th) Weekdays '0'-'0' (30h, 30h) : Sunday '0'-'1' (30h, 31h) : Monday '0'-'2' (30h, 32h) : Tuesday '0'-'3' (30h, 33h) : Wednesday '0'-'4' (30h, 34h) : Thursday '0'-'5' (30h, 35h) : Friday '0'-'6' (30h, 36h) : Saturday 16th-17th)
  • NEC PN-ME502 | External Control Codes - Page 26
    STX Code 'C' '3' '1' '6' 02h 43h 33h 31h 36h 1st 2nd-5th Serial Number strings Data(0) - Data(N) xxh - xxh 6th-17th ETX ASCII 03h HEX 18th 1st) STX:Start Message Responds with the ASCII code 'STX' (02h). 2nd-5th) Command Code: 'C'-'3'-'1'-'6' (43h, 33h, 31h, 36h) 6th-xxth) Serial Number
  • NEC PN-ME502 | External Control Codes - Page 27
    Command STX Code 'C' '3' '1' '7' 02h 43h 33h 31h 37h 1st 2nd-5th Model Name strings Data(0) - Data(N) xxh - xxh 6th-xxth ETX ASCII 03h HEX (xx+1)th 1st) STX:Start Message Responds with the ASCII code 'STX' (02h). 2nd-5th) Command Code: 'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h) 6th-xxth) Model
  • NEC PN-ME502 | External Control Codes - Page 28
    02h 43h 32h 31h 44h xxh xxh 1st 2nd-5th 6th-7th 1st digit 'x' 'x' xxh xxh 8th-9th Message 4 digit passcode 2st digit 3st digit 'x' 'x' 'x' 'x' xxh xxh xxh xxh 10th-11th 12th-13th 4st digit 'x' 'x' xxh xxh 14th-15th ETX ASCII 03h HEX 6th 1st) STX:Start of Message Specify the ASCII code
  • NEC PN-ME502 | External Control Codes - Page 29
    16th) ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor → Controller(ACK)】 Command STX Code 'C' '3' '1' 02h 43h 33h 31h 1st 2nd-5th Message Result Code 'D' 'x' 'x' 44h xxh xxh 6th-7th Current Mode 'x' 'x' xxh xxh 8th-9th ETX ASCII 03h HEX 10th 1st) STX:Start of Message
  • NEC PN-ME502 | External Control Codes - Page 30
    1st) STX:Start Message Specify the ASCII code 'STX' (02h). 2nd-5th) Command Code: 'C'-'2'-'2'-'0' (43h, 32h, 32h, 30h) 6th-7th) Reserved: '0'-'0' (30h, 30h) 8th) ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Message Command Select STX Code Device 'C'
  • NEC PN-ME502 | External Control Codes - Page 31
    【Controller → Monitor】 Message Command STX Code Index IP Version IP address Oct1 IP address Oct2 'C' '2' '2' 'B' '0' 'E' '0' '4' 'x' 'x' 'x' 'x' 02h 43h 32h 32h 42h 30h 45h 30h 34h xxh xxh xxh xxh 1st 2nd-5th 6th-7th 8th-9th 10th-11th 12th-13th Message IP address IP address Oct3
  • NEC PN-ME502 | External Control Codes - Page 32
    Responds with the ASCII code 'STX' (02h). 2nd-5th) Command Code: 'C'-'3'-'1'-'D' (43h, 33h, 31h, 44h) 6th-7th) Result Code '0'-'0' (30h, 30h) : Normal '0'-'1' (30h, 31h) : abnormal PING is succeeded PING execution is Failed. 8th-9th) Index' 0'-'E' 0E(30h 45h) 10th ETX: End of Message Responds
  • NEC PN-ME502 | External Control Codes - Page 33
    Year 'x' x' xxh xxh 22th-23th Month 'x' x' xxh xxh 24th-25th Day 'x' x' xxh xxh 26th-27th Message Order Ext1 'x' x' xxh xxh 28th-29th '0' '0' 30h 30h 30th-31th Ext2 '0' '0' 30h 30h 32th-33h Ext3 '0' '0' 30h 30h 34th-35th ETX 03h 36th 1st) STX:Start Message Responds with the ASCII code
  • NEC PN-ME502 | External Control Codes - Page 34
    CTL-C23E. Schedule Write for details. 20th -21th)Picture mode Not supported by this monitor. '0' for all. 22th -23th)Year Date of Execution Not supported by this monitor. '0' for all. 24th -25th)Month Date of Execution Not supported by this monitor. '0' for all. 26th -27th)Day Date of Execution
  • NEC PN-ME502 | External Control Codes - Page 35
    'x' x' xxh xxh 14th-15th 'x' x' xxh xxh 16th-17th 'x' x' xxh xxh 18th-19th 'x' x' xxh xxh 20th-21th Year 'x' x' xxh xxh 22th-23th Month 'x' x' xxh xxh 24th-25th Day 'x' x' xxh xxh 26th-27th Message Order Ext1 'x' x' xxh xxh 28th-29th '0' '0' 30h 30h 30th-31th Ext2 '0' '0' 30h 30h
  • NEC PN-ME502 | External Control Codes - Page 36
    bit 6 : Sun More than one may be set up at the same time. For examples) Mon and Sat are set at the same time. bit0,bit5 → 0100001 → 0x21 →'2'-'1' (32h, 31h) If Schedule event is "Reboot", Day of the week setting is ignored, and Reboot is executed everyday. 18th -19th)Schedule Type Specify a bit
  • NEC PN-ME502 | External Control Codes - Page 37
    Year 'x' x' xxh xxh 24th-25th Month 'x' x' xxh xxh 26th-27th Day 'x' x' xxh xxh 28th-29th Message Order Ext1 'x' x' xxh xxh 30th-31th '0' '0' 30h 30h 32th-33th Ext2 '0' '0' 30h 30h 34th-35th Ext3 '0' '0' 30h 30h 36th-37th ETX 03h 38th 1st) STX:Start Message Responds with the ASCII
  • NEC PN-ME502 | External Control Codes - Page 38
    bit 5 bit 6 : Sat : Sun 20th -21th)Schedule Type bit 0 : (Reserved) bit 1 : WEEK bit 2 : Enable/Disable bit 3 : (Reserved) bit 4 : (Reserved) bit 5 : (Reserved) bit 6 : (Reserved) bit 7 : (Reserved) the week of execution Enable/disable designated program number 22th -23th)Picture mode 24th -
  • NEC PN-ME502 | External Control Codes - Page 39
    10th)ETX: Message End Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Command STX Code 'C' '3' '3' 'F' 02h 43h 33h 33h 46h 1st 2nd-5th Message Result Code 'x' x' xxh xxh 6th-7th Program No 'x' x' xxh xxh 8th-9th Enable/ Disable 'x' x' xxh xxh 10th-11th ETX 03h ASCII 10th
  • NEC PN-ME502 | External Control Codes - Page 40
    2nd-7th) Command Code: 'C'-'A'-'0'-'4'-'0'-'0' (43h, 41h, 30h, 34h, 30h, 30h) 8th) ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Command STX Code 'C' 'B' '0' '4' 02h 43h 42h 30h 32h 1st 2nd-7th Message '0' '0' 30h 30h Input Name Data(0) - Data(N) xxh -
  • NEC PN-ME502 | External Control Codes - Page 41
    8th-xxth) Input Name Specify the name of the rewritten Input Name according to the following rules. Ex.)In case "HDMI1" "HDMI1" = 48h, 44h, 4Dh, 49h, 31h = Data(0) : '4' (34h) 'H' Data(1) : '8' (38h) Data(2) : '4' (34h) 'D' Data(3) : '4' (34h) Data(4) : '4' (34h) 'M' Data(5) : 'D' (44h)
  • NEC PN-ME502 | External Control Codes - Page 42
    8th ETX: End of Message Specify the ASCII code 'ETX' (03h). 【Monitor → Controller(ACK)】 Message Command Result STX Code Code ETX 'C' 'B' '0' '4' '0' '2' 'x' 'x' ASCII 02h 43h 42h 30h 32h 30h 32h xxh xxh 03h HEX 1st 2nd-7th 8th-9th 10th 1st) STX:Start of Message Responds with the ASCII
  • NEC PN-ME502 | External Control Codes - Page 43
    'C' 'B' '0' '4' 02h 43h 42h 30h 32h 1st 2nd-7th '0' '3' 'x' 'x' 30h 33h xxh xxh 8th-9th 'x' 'x' xxh xxh 10th-11th Message Input Name Data(0) - Data(N) xxh - xxh 12th-xxth ETX ASCII 03h HEX (xx+1)th 1st) STX:Start of Messgae Responds with the ASCII code 'STX' (02h). 2nd-7th) Command Code:
  • NEC PN-ME502 | External Control Codes - Page 44
    Command STX Code 'C' 'A' '0' '4' 02h 43h 41h 30h 34h 1st 2nd-7th Input Terminal '0' '4' 'x' 'x' 30h 34h xxh xxh 8th-9th Input Name Data(0) - Data(N) xxh - xxh 10th-xxth 1st) STX:Start of Message Specify the ASCII code 'STX' (02h). 2nd-7th) Command Code: 'C'-'A'-'0'-'4'-'0'-'4' (43h, 41h,
  • NEC PN-ME502 | External Control Codes - Page 45
    1st) STX:Start of Message Specify the ASCII code 'STX' (02h). 2nd-7th) Command Code: 'C'-'A'-'0'-'4'-'0'-'5' (43h, 41h, 30h, 34h, 30h, 35h) 8th-9th) Input Terminal '1'-'1' (31h, 31h) : HDMI1 '1'-'2' (31h, 31h) : HDMI2 '8'-'2' (38h, 32h) : HDMI3 '8'-'9' (38h, 39h) : USB-C 'C'-'0' (43h, 30h) : HOME
  • NEC PN-ME502 | External Control Codes - Page 46
    (43h, 42h, 30h, 42h,) 6th-7th)Index : '0'-'0' (30h, 30h,) 8th-9th) Power Save Mode '0'-'0' (30h, 30h) : ENABLE '0'-'1' (30h, 31h) : Not Support '0'-'2' (30h, 32h) : DISABLE 10th ETX: MessageEnd Responds with the ASCII code 'ETX' (03h). 5.2.25. CTL-CA0B-01. Power Save Mode Write Request This
  • NEC PN-ME502 | External Control Codes - Page 47
    8th-9th) Power Save Mode '0'-'0' (30h, 30h) : ENABLE '0'-'1' (30h, 31h) : Not Support '0'-'2' (30h, 32h) : DISABLE 10th ETX: Message is end. Specify the ASCII code 'ETX' (03h). 【Monitor→Controller(ACK)】 Command STX Code 'C' 'B' '0' 02h 43h 42h 30h 1st
  • NEC PN-ME502 | External Control Codes - Page 48
    'C' 'B' '0' 'B' 02h 43h 42h 30h 42h 1st 2nd-7th '0' '2' 'x' 'x' ASCII 30h 32h xxh xxh 03h HEX 8th-9th 10th 1st) STX:Start of Message Responds with the ASCII code 'STX' (02h). 2nd-7th) Command Code: 'C'-'B'-'0'-'B'-'0'-'2' (43h, 42h, 30h, 43h, 30h, 32h) 8th-9th) Time Setting Returns the
  • NEC PN-ME502 | External Control Codes - Page 49
    2nd-7th) Command Code: 'C'-'B'-'0'-'B'-'0'-'3' (43h, 42h, 30h, 43h, 30h, 33h) 8th-9th) Result Code '0'-'0' (30h, 30h) : No error '0'-'1' (30h, 31h) : Error 10th ETX: End of Message Responds with the ASCII code 'ETX' (03h). 5.2.28 CTL-CA0F-00. Get Terminal List This command is used in order to read
  • NEC PN-ME502 | External Control Codes - Page 50
    8th-9th) Result Code '0'-'0' (30h, 30h) : No error '0'-'1' (30h, 31h) : Error 10th-11th) Number of Terminal Returns the number of terminal. Ex ) If number of terminals is 5, please respond the following. '0'-'5' (30h, 35h) : 5 terminals. Notes : For Aladdin, the number of terminals is 5. 12th-
  • NEC PN-ME502 | External Control Codes - Page 51
    6. VCP Command 6.1 VCP Command table The VCP commands supported by this unit are as follows. OP Code OP Code Page Parameter 0000H - 0064H 00h 10h ( Dark ) - ( Bright ) 0000H - 0064H 00h 12h ( Low ) - ( High ) 0002h :
  • NEC PN-ME502 | External Control Codes - Page 52
    0000H - 000AH 00h 8Fh ( De-emphasized ) - ( Emphasized ) AUDIO Treble 0000H - 000AH 00h 91h ( De-emphasized ) - ( Emphasized ) AUDIO Bass 0000H - 0064H 00h 92h ( Dark ) - ( Bright ) Video black level 0000H - 0019H - 0032H 00h 93h ( L50 ) - (Center) - ( R50 ) 0000H - 0064H 00h 9Bh (
  • NEC PN-ME502 | External Control Codes - Page 53
    0001H : Normal 0002H : Full 0003H : Wide 0004H : Zoom 02h 70h 0007H : OFF(1:1) 02h 79h 0000H - FFFFH 0001H : OFF 0002H : Low 02h 8Dh 0004H : High 02h B4h 0000H - FFFFH 0001h : ON 02h BEh 0002h : OFF 0000H : No mean 0001H : All(=Factory Reset) 0002H : Picture 0004H : Audio 0010H
  • NEC PN-ME502 | External Control Codes - Page 54
    10h 29h 0000H - FFFFH 10h 2Ah 0000H - 03E7H 10h 2Bh 0000H - FFFFH 0000H : --- 0011H : HDMI1 0012H : HDMI2 0082H : HDMI3 0089H : USB-C 10h 2Eh 0087h : Home 0000H : --- 0011H : HDMI1 0012H : HDMI2 0082H : HDMI3 0089H : USB-C 10h 2Fh 0087h : Home 0000H : --- 0011H : HDMI1 0012H :
  • NEC PN-ME502 | External Control Codes - Page 55
    0000H - 0064H 10h C6h ( Dark ) - ( Bright ) 0000H - 0064H 10h C7h ( Small ) - ( Big ) 0001H : OFF 10h C8h 0002H : ON 0001H : OFF 10h CAh 0002H : ON 0000H - 0064H 10h CBh ( Small ) - ( Big ) 0011h : HDMI1 0012h : HDMI2 0082h : HDMI3 0089h : USB-C 10h D0h 0087h : Home 0000H : No
  • NEC PN-ME502 | External Control Codes - Page 56
    0001H : settings1 11h 68h 0002H : settings2 0000H : No mean 0001H : UNLOCK 0002H : ALL LOCK 11h 6Ah 0003H : CUSTOM LOCK 0000H : No mean 0001H : UNLOCK 11h 6Bh 0002H : LOCK 0000H : No mean 0001H : UNLOCK 11h 6Ch 0002H : LOCK 0000H - 0064H 11h 6Dh ( 0 ) - ( 100 ) 0000H - 0064H 11h
  • NEC PN-ME502 | External Control Codes - Page 57
    0000H - 0064H 11h F6h ( Dark ) - ( Bright ) 0000H - 0064H 11h FCh ( 0 ) - ( 100 ) Auto dimming - IN DARK - Illuminance AMBIENT LIGHT SENSING - Backlight ※Read only 57/63
  • NEC PN-ME502 | External Control Codes - Page 58
    7. OSD menu correspondence table (Common menu) OSD itmes PICTURE PICUTER MODE BACKLIGHT BACKLIGHT DIMMING VIDEO BALACK LEVEL GAMMA COLOR COLOR COLOR TEMP R GAIN G GAIN B GAIN COLOR CONTROL R Y G C B M CONTRAST ADVANCED HDR MODE SHARPNESS ADAPTIVE CONTRAST ASPECT ZOOM AMBIENT LIGHT SENSING AUDIO
  • NEC PN-ME502 | External Control Codes - Page 59
    Obtain IP Address Automatically N/A IP SETTING N/A DEFAULT GATEWAY N/A SUBNET MASK N/A DNS1 N/A DNS2 N/A MAC ADDRESS N/A Proxy N/A [Manual]Proxy Host Name N/A [Manual]Proxy Port N/A [Manual]Bypass Proxy Fro N/A [Auto] Pac Wireless LAN Bluetooth PING CTL C22B-0E-04 Network
  • NEC PN-ME502 | External Control Codes - Page 60
    Crestron RESET PROTECT POWER SAVE SETTINGS POWER SAVE TIME SETTING MODEL USB POWER POWER SAVE MESSAGE QUICK START SECURITY SETTINGS PASSWORD Lock Admi Setting START-UP LOCK CONTROL LOCK LOCK SETTINGS SELECT MODE POWER VOLUME MIN VOL MAX VOL INPUT ACTIVATE ADVANCED User Apps Installatio Application
  • NEC PN-ME502 | External Control Codes - Page 61
    VOLUME INPUT WAIT TIME CLONE SETTING ADVANCED POWER INDICATOR MUTE SETTING Communication Format EXTERNAL CONTROL MONITOR ID Application Hide System Show System Restet app preference SYSTEM DATE&TIME Language & Keyboard LANGUAGE Virtual Keyboard Physical Keyboard Current Keyboard OSD OSD TIME
  • NEC PN-ME502 | External Control Codes - Page 62
    CARBON USAGE Legal Information VCP 10h 2Bh Notes : For details on each CTL command, refer to "5.CTL Command". For details on each CTL command, refer to "6.VCP Command". 62/63
  • NEC PN-ME502 | External Control Codes - Page 63
    8. Notes 8.1 Command reception at power off and power save. When the monitor is "power off" or "power save", the commands that can be received are limited to the following commands. CTL Command CTL Number CTL-B1 CTL-C03F CTL-01D6 CTL-C203-D6 CTL-C216 CTL-C217 CTL-CA20 Explanation Self-diagnosis
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

R1.0
External Control
ME series
PN-ME432/PN-ME502
/PN-ME552/PN-ME652
1/63