10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: COLOR Gain Flag DATA02: COLOR Gain * COLOR Gain is from -22 (EAH) to +22 (16H) only during video. 01H 04H E0H: -32 FFH: -01 00H: 0 01H: +01 20H: +32 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: COLOR Gain Flag 04H 13. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor. Transmission Data DFH 80H 60H 00H 01H DATA00 CKS DATA00: 00H: 1 01H: 2 02H: 3 03H: PRO ACK 7FH 60H 80H 00H 01H DATA00 CKS DATA00: 00H: 1 01H: 2 02H: 3 03H: PRO NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP change of the following R/G/B GAIN data cannot be accepted. 11.TINT Gain Data Function The external control equipment changes the TINT gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: TINT Gain Flag DATA02: TINT Gain * TINT Gain is from -22 (EAH) to +22 (16H) only during video. 01H 05H E0H: -32 FFH: -01 00H: 0 01H: +01 20H: +32 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: TINT Gain Flag 05H 12. PICTURE MODE Select Function The external control equipment sets the picture mode of the plasma monitor. Transmission Data 14. RED Gain Data Function The external control equipment changes the RED Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00: USER PICTURE Gain Flag DATA01: RED Gain Flag DATA02: RED Gain 1 (Bias) 01H 01H D8H: -40 FFH: -1 00H: 0 DATA03: RED Gain 2 (Drive) IEH: +30 D8H: -40 FFH: -1 00H: 0 IEH: +30 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: RED Gain Flag 01H DFH 80H 60H 0AH 01H DATA00 CKS DATA00: 01H: MEMORY 02H: THEATER 03H: NORMAL 04H: RESET ACK 7FH 60H 80H 0AH 01H DATA00 CKS DATA00: 01H: MEMORY 02H: THEATER 03H: NORMAL 04H: RESET 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

42
10. COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
COLOR Gain Flag
04H
DATA02:
COLOR Gain
E0H: -32
* COLOR Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
COLOR Gain Flag
04H
11.TINT Gain Data
Function
The external control equipment changes the TINT gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
TINT Gain Flag
05H
DATA02:
TINT Gain
E0H: -32
* TINT Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01 CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
TINT Gain Flag
05H
12. PICTURE MODE Select
Function
The external control equipment sets the picture mode of the plasma monitor.
Transmission Data
DFH
80H
60H
0AH
01H
DATA00
CKS
DATA00:
01H: MEMORY
02H: THEATER
03H: NORMAL
04H: RESET
ACK
7FH
60H
80H
0AH
01H
DATA00
CKS
DATA00:
01H: MEMORY
02H: THEATER
03H: NORMAL
04H: RESET
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH
80H
60H
00H
01H
DATA00
CKS
DATA00:
00H: 1
01H: 2
02H: 3
03H: PRO
ACK
7FH
60H
80H
00H
01H
DATA00
CKS
DATA00:
00H: 1
01H: 2
02H: 3
03H: PRO
NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP
change of the following R/G/B GAIN data cannot be accepted.
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
04H
DATA00 to DATA03
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
RED Gain Flag
01H
DATA02:
RED Gain 1 (Bias)
D8H: -40
FFH: -1
00H: 0
IEH: +30
DATA03:
RED Gain 2 (Drive)
D8H: -40
FFH: -1
00H: 0
IEH: +30
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
RED Gain Flag
01H