NEC PX-61XM1A 61MP1 - Page 49
COLOR Gain Data, TINT Gain Data, PICTURE MODE Select, COLOR TEMP SELECT, RED Gain Data
View all NEC PX-61XM1A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: COLOR Gain Flag DATA02: COLOR Gain * COLOR Gain is from -22 (EAH) to +22 (16H) only during video. 01H 04H E0H: -32 FFH: -01 00H: 0 01H: +01 20H: +32 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: COLOR Gain Flag 04H 13. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor. Transmission Data DFH 80H 60H 00H 01H DATA00 CKS DATA00: 00H: 1 01H: 2 02H: 3 03H: PRO ACK 7FH 60H 80H 00H 01H DATA00 CKS DATA00: 00H: 1 01H: 2 02H: 3 03H: PRO NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP change of the following R/G/B GAIN data cannot be accepted. 11.TINT Gain Data Function The external control equipment changes the TINT gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: TINT Gain Flag DATA02: TINT Gain * TINT Gain is from -22 (EAH) to +22 (16H) only during video. 01H 05H E0H: -32 FFH: -01 00H: 0 01H: +01 20H: +32 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: TINT Gain Flag 05H 12. PICTURE MODE Select Function The external control equipment sets the picture mode of the plasma monitor. Transmission Data 14. RED Gain Data Function The external control equipment changes the RED Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00: USER PICTURE Gain Flag DATA01: RED Gain Flag DATA02: RED Gain 1 (Bias) 01H 01H D8H: -40 FFH: -1 00H: 0 DATA03: RED Gain 2 (Drive) IEH: +30 D8H: -40 FFH: -1 00H: 0 IEH: +30 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: RED Gain Flag 01H DFH 80H 60H 0AH 01H DATA00 CKS DATA00: 01H: MEMORY 02H: THEATER 03H: NORMAL 04H: RESET ACK 7FH 60H 80H 0AH 01H DATA00 CKS DATA00: 01H: MEMORY 02H: THEATER 03H: NORMAL 04H: RESET 42