Netgear GS752TPPv3 User Manual

Netgear GS752TPPv3 Manual

Netgear GS752TPPv3 manual content summary:

  • Netgear GS752TPPv3 | User Manual - Page 1
    User Manual 24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports and Optional Remote/Cloud Management GS728TPv3 GS728TPPv3 GS752TPv3 GS752TPPv3 April 2023 202-12674-01 NETGEAR, Inc. 350 E. Plumeria Drive San Jose, CA 95134, USA
  • Netgear GS752TPPv3 | User Manual - Page 2
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Support and Community Visit netgear.com/support to get your questions answered and access the latest downloads. You can also check out our NETGEAR Community for helpful advice at community.netgear.com.
  • Netgear GS752TPPv3 | User Manual - Page 3
    Contents Chapter 1 Get Started Available publications and online help 18 Switch management options and default management mode....18 Manage the switch by using the device UI 20 Device UI buttons and user-defined fields 20 Interface naming conventions 21 Save your changes in the device UI 21
  • Netgear GS752TPPv3 | User Manual - Page 4
    ports using the Device View 43 Access the NETGEAR support website 45 Access the user manual online 46 Chapter 2 Configure Switch System Settings Dashboard information 52 Display information about switch hardware components and firmware 54 Display the power supply information 54 Display the
  • Netgear GS752TPPv3 | User Manual - Page 5
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change an entry in the static DNS host mapping table.......84 for a host 106 Configure SNMPv1 and SNMPv2 trap flags 107 Display the supported MIBs 108 Configure the SNMPv3 user account 109 Configure HTTP access settings 110
  • Netgear GS752TPPv3 | User Manual - Page 6
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure membership interfaces for a VLAN 127 Change a VLAN 129 Delete one or more VLANs 130 Reset the entire VLAN configuration to default setting..........131 Change
  • Netgear GS752TPPv3 | User Manual - Page 7
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Chapter 4 Configure Switching LLDP and LLDP-MED settings for interfaces 175 Configure LLDP interface settings 175 Configure LLDP-MED interface settings 177 Power over Ethernet
  • Netgear GS752TPPv3 | User Manual - Page 8
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Remove a static MAC address from the MAC address table..231 DHCP snooping 232 Enable DHCP snooping for the switch 232 Enable DHCP snooping for a VLAN
  • Netgear GS752TPPv3 | User Manual - Page 9
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Enable IGMP snooping on the Auto-Video VLAN 280 Multicast Listener Discovery snooping 281 Enable MLD snooping 282 Configure the MLD snooping settings for an
  • Netgear GS752TPPv3 | User Manual - Page 10
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Add routing to an existing VLAN and display routing VLAN 802.1p priorities to queues 362 Map DSCP values to queues 364 Differentiated Services 365 Defining DiffServ 366 Configure the DiffServ mode and display the entries in
  • Netgear GS752TPPv3 | User Manual - Page 11
    + Smart Switches with 4 SFP Ports User Manual Change the attributes for an existing DiffServ policy.........384 Remove a DiffServ policy 385 Attach a DiffServ policy to an interface 386 Remove a DiffServ policy from an interface 387 Display DiffServ service statistics 388 Chapter 8 Manage Switch
  • Netgear GS752TPPv3 | User Manual - Page 12
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual MAC filters for traffic control 434 Create a MAC filter for a the loop protection state 450 Denial of service 452 Configure Auto-DoS 452 Configure individual denial of service attack options 454 Chapter 9 Configure Access
  • Netgear GS752TPPv3 | User Manual - Page 13
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change the match criteria for a basic IPv4 ACL rule 486 ACL binding 515 Display or delete VLAN ACL bindings 516 Chapter 10 Maintenance and Troubleshooting Reboot the switch from the device UI 520 Reset the switch to factory
  • Netgear GS752TPPv3 | User Manual - Page 14
    Manual Change the software image that loads when the switch starts.541 Display the dual image configuration and add image descriptions 542 Copy a software image from one flash sector to another......543 Delete a software image 544 Diagnostics and troubleshooting Services (DiffServ 601 14
  • Netgear GS752TPPv3 | User Manual - Page 15
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual DiffServ classes 602 DiffServ traffic classes 602 DiffServ policies 603 DiffServ traffic GS728TPv3 and GS728TPPv3 hardware technical specifications 647 Models GS752TPv3 and GS752TPPv3 hardware technical specifications 648 15
  • Netgear GS752TPPv3 | User Manual - Page 16
    PoE+ Smart Switch With 4 SFP Ports. This model provides a PoE power budget of 380W. • GS752TPv3: NETGEAR 48-Port Gigabit PoE+ Smart Switch With 4 SFP Ports. This model provides a PoE power Configure ports using the Device View • Access the NETGEAR support website • Access the user manual online 16
  • Netgear GS752TPPv3 | User Manual - Page 17
    features and bug fixes are made available from time to time at netgear.com/support/download/. Some products can regularly check the site and download new firmware, or you can check for and download new firmware manually. If the features or behavior of your product does not match what is described
  • Netgear GS752TPPv3 | User Manual - Page 18
    your switch by visiting netgear.com/support/download and entering your model number in the search box. • Installation Guide • Hardware Installation Guide • Main User Manual (this manual) • Audio Video User Manual • Software Administration Manual • CLI Command Reference Manual When you are logged in
  • Netgear GS752TPPv3 | User Manual - Page 19
    CLI, see the CLI manual. To find the CLI manual, visit netgear.com/support/download and enter your model the switch and network usage; and, if necessary, troubleshoot the switch and the network. - NETGEAR Insight app: app, visit netgear.com/business/services/insight. The Insight Cloud Portal and
  • Netgear GS752TPPv3 | User Manual - Page 20
    with 4 SFP Ports User Manual Manage the switch by using the device UI This manual describes how to use the services/insight. The Insight Cloud Portal and Insight app have embedded help and are documented in multiple knowledge base articles that you can access by visiting netgear.com/support
  • Netgear GS752TPPv3 | User Manual - Page 21
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 2. Invalid characters for user-defined fields Invalid characters for user-defined fields \ | / * ? Interface naming conventions The switch supports physical and logical interfaces. Interfaces are identified by their
  • Netgear GS752TPPv3 | User Manual - Page 22
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Context-sensitive help When you log in to the switch, every page contains a link to the online help computer to access the switch on-network and connected to the Internet on page 23. Get Started 22 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 23
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you use a Mac, or if you do not know the IP address of the switch, use one of the . You can use a WiFi or wired network connection. 4. Open File Explorer. 5. Click the Network link. Get Started 23 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 24
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. If prompted, enable the Network Discovery feature. 7. Under Network Infrastructure, locate the switch model number. 8. the credentials, see Credentials for the device UI on page 31. Get Started 24 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 25
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. If you enter a registration key, click the you did not set up a NETGEAR account, tap Create NETGEAR Account and follow the onscreen instructions. 5. Enter the email address and password for your account and tap LOG IN. After
  • Netgear GS752TPPv3 | User Manual - Page 26
    4 SFP Ports User Manual Use the NETGEAR Switch Download the Switch Discovery Tool by visiting netgear.com/support/product/netgear-switch-discovery-tool. Depending on the on your Mac dock or Windows desktop. 4. Reenable the security services on your computer. 5. Power on the switch. The DHCP server
  • Netgear GS752TPPv3 | User Manual - Page 27
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. Enter your credentials, which depend on the page that displays: • Register to activate your warranty new password. The Dashboard page displays. You can now configure the switch. Get Started 27 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 28
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Use other options to discover the switch IP address If the switch is on-network, you can use switch with your NETGEAR account and get a registration key for offline access on page 34. Get Started 28 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 29
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual - Skip Registration & Access the UI: You do not need to register the switch to activate your warranty, but if network must be in the same subnet as the default IP address of the switch. Get Started 29 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 30
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To access the switch off-network and enter the registration key before you log in to the device UI: to the device UI, you changed the management mode to NETGEAR Insight, and you added Get Started 30 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 31
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual the switch to an Insight network location, enter the Insight network password to access the device your customized device admin password. • NETGEAR Insight network location password: Get Started 31 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 32
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual NETGEAR Insight can affect how you access the switch device functions and for knowledge base articles about NETGEAR Insight, visit netgear.com/support/product/insight. The following table lists the essential credential options for
  • Netgear GS752TPPv3 | User Manual - Page 33
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual NETGEAR server. For more information, see Register and access the switch on-network with your NETGEAR account password. The Dashboard page displays. You can now configure the switch. Get Started 33 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 34
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Register the switch with your NETGEAR account and get a documented in multiple knowledge base articles that you can access by visiting netgear.com/support/product/insight. To register the switch with your NETGEAR account and get a
  • Netgear GS752TPPv3 | User Manual - Page 35
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Access the switch with a registration key After you get a registration key, you can access the switch either static IP address to the switch, enter the static IP address of the switch. Get Started 35 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 36
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Enter Registration Key page displays. 5. Type or paste the key 6. Click the Submit button. 7. If the an Insight network location, enter the Insight network password to access the Get Started 36 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 37
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual device UI. (In such a situation, the Insight network password replaces the switch device admin password.) For enter the Insight network password for the last Insight network location. Get Started 37 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 38
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device UI on page 31. 4. Click the Login button. Interface. You can then access the device UI for settings that are not Get Started 38 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 39
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Insight-manageable, for complex tasks such as integrating with an existing network of devices that are 32. 3. Enter one of the following passwords: • Enter your device admin password. Get Started 39 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 40
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight switch with the Insight Cloud Portal and Insight app, visit netgear.com/business/services/insight. The Insight Cloud Portal and Insight app have embedded help and are
  • Netgear GS752TPPv3 | User Manual - Page 41
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change the management mode back to Directly Connect to Web-browser Interface After you change the up window displays. 7. Click the OK button. The System Information page display again. Get Started 41 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 42
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Click the Apply button. An alert pop-up window displays. 9. Click the OK button. The pop-up window closes Access the switch off-network and not connected to the Internet on page 29. Get Started 42 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 43
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual d. Enter the device admin password. The default device admin 11 by doing the following: a. Select Maintenance > Update > HTTP Firmware/File Update. The HTTP Firmware/File Update page displays. b. From the File Type menu, select Text
  • Netgear GS752TPPv3 | User Manual - Page 44
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure ports using the Device View: 1. Connect your computer to the same network as the a menu item. The associated page displays, allowing you to configure or monitor the port. Get Started 44 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 45
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Access the NETGEAR support website From the device UI, you can access the NETGEAR support website at netgear.com/support. To access the NETGEAR support website from the device UI: 1. Connect your computer to the same network
  • Netgear GS752TPPv3 | User Manual - Page 46
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Access the user manual online The user manual (the manual that you are now reading) is available from the NETGEAR download center at netgear.com/support/download/. To access the user manual online from the device UI: 1. Connect your computer
  • Netgear GS752TPPv3 | User Manual - Page 47
    and display general switch system information and NETGEAR Insight Cloud application information • Display information about switch hardware components and firmware • IP network settings for management access • Time and SNTP settings • Domain Name System • Manage switch discovery protocols • Display
  • Netgear GS752TPPv3 | User Manual - Page 48
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Dashboard The information that is displayed on the dashboard is mostly self-explanatory. Display port (PoE) from the switch The total number of disabled ports Configure Switch System 48 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 49
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual (Continued) Field Description Connected and Powered The total number of ports that are connected to a PD see Configure ports using the Device View on page 43. Configure Switch System 49 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 50
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display VLAN membership The Dashboard displays information about VLAN membership on the switch. To display details The Dashboard displays switch device details. Configure Switch System 50 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 51
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display switch device details: 1. Connect your computer to the same network as the switch. You can , see IP network settings for management access on page 59. Configure Switch System 51 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 52
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual (Continued) Field Date & Time Firmware Version Description The current date and time. For more information, see Time and SNTP settings on page 67. The active main firmware version of the switch (see Manage software images on page
  • Netgear GS752TPPv3 | User Manual - Page 53
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device UI on page 31. 4. Click the Login button table describes the system information on the page. Configure Switch System 53 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 54
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 6. System information Field Product Name System Up Time MIB of the switch Display information about switch hardware components and firmware You can display information about switch hardware components such as power supplies
  • Netgear GS752TPPv3 | User Manual - Page 55
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your UI.) Display the boot and software version You can display the boot and software (firmware) versions that are running on the switch. To display the boot and software versions:
  • Netgear GS752TPPv3 | User Manual - Page 56
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register the version information. Table 8. Version information Field Model Name Boot Version Firmware Version Description The model number of the switch The version of the boot
  • Netgear GS752TPPv3 | User Manual - Page 57
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and the power, CPU, and other chipsets, and allow the chipsets work normally. Configure Switch System 57 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 58
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the status of the fans: 1. Connect your computer to the same network as the switch. You can Fan-1 The type of fan is always Fixed The speed of the fan Configure Switch System 58 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 59
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 10. Fan information (Continued) Field Duty Level (%) State Description The duty level of the the following passwords: • Enter your device admin password. Configure Switch System 59 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 60
    The IP Network Configuration page displays. 6. Select a radio button for the configuration of the switch management interface: • Static IP Address: You must manually configure the IP address, subnet mask, and default gateway. Enter this information in the fields below the radio buttons. • Dynamic IP
  • Netgear GS752TPPv3 | User Manual - Page 61
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Note: Make sure that the VLAN that must be the management VLAN exists. Also make sure that Management VLAN field, type the new management VLAN ID of the switch. Configure Switch System 61 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 62
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You can type an ID in the range of 1 to 4093, but make sure that the new management VLAN UI on page 31. 4. Click the Login button. The Dashboard page displays. Configure Switch System 62 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 63
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select System > Management > IP Network > IPv6 Network Configuration. The IPv6 Network Configuration page displays. need for the IPv6 management interface. Configure Switch System 63 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 64
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual When you add a static IPv6 address, you need to configure an IPv6 prefix and IP Network > IPv6 Network Configuration. The IPv6 Network Configuration page displays. Configure Switch System 64 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 65
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. To add an IPv6 address, in the IPv6 Management Interface Configuration section, do the following: a. of the switch in the address field of your web browser. Configure Switch System 65 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 66
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and device Indicates if the neighboring device is a router (True) or not (False) Configure Switch System 66 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 67
    for the neighboring device was updated Time and SNTP settings The switch supports the Simple Network Time Protocol (SNTP). As its name suggests, calculates the date and time using its CPU's clock cycle. To set the time manually: 1. Connect your computer to the same network as the switch. You can
  • Netgear GS752TPPv3 | User Manual - Page 68
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For on page 71) that the switch can contact for time keeping. Configure Switch System 68 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 69
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure SNTP for the time settings and configure the global SNTP settings: 1. Connect your computer range is from 0 to 59 minutes. The default is 0 minutes. Configure Switch System 69 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 70
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The following steps refer to the SNTP Global Configuration section. 8. Select a Client Mode radio is 1. 14. Click the Apply button. Your settings are saved. Configure Switch System 70 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 71
    Switches with 4 SFP Ports User Manual SNTP servers SNTP assures accurate time as an SNTP client only and does not provide time services to other devices. Time sources are established by stratums. interval. Add an SNTP server The switch can support three SNTP servers, and might be preconfigured
  • Netgear GS752TPPv3 | User Manual - Page 72
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add an SNTP server: 1. Connect your computer to the same network as the switch. You can use a WiFi is sent to it. 9. In the Port field, type the port number. Configure Switch System 72 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 73
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual This is the UDP port on the SNTP server to which 2, and the third server priority 3. 11. In the Version field, type the NTP version that is supported by the switch. The range is from 1 to 4. The default is 4. 12. Click the Save
  • Netgear GS752TPPv3 | User Manual - Page 74
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select System > Management > Time > SNTP Server Click the Login button. The Dashboard page displays. Configure Switch System 74 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 75
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select System > Management > Time > SNTP Server Configuration. The SNTP Server Configuration page displays. Status table displays the following information. Configure Switch System 75 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 76
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 12. SNTP server status information Field Address Last SNTP server is not valid. • Version Not Supported: The SNTP version supported by the server is not compatible with the version supported by the client. • Server Unsynchronized: The
  • Netgear GS752TPPv3 | User Manual - Page 77
    Disable: Disables daylight saving time. This is the default setting. • Recurring: Daylight saving time occurs at the same time every year. You must manually configure the start and end times and dates for the time shift. Configure the settings that are described in Step 7. • Recurring EU: The system
  • Netgear GS752TPPv3 | User Manual - Page 78
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Field Begins At Description These fields are used to configure the start values of the day and time. configure the fields that are shown in the following table. Configure Switch System 78 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 79
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Field Begins At Description These fields are used to configure the start values of the date and time. • network and not connected to the Internet on page 29. Configure Switch System 79 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 80
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to the network uses and how the switch operates as a DNS client. Configure Switch System 80 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 81
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure the global DNS settings and add a DNS server You can configure the global DNS settings and the name). The maximum length of the name is 255 characters. Configure Switch System 81 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 82
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Click the Apply button. Your settings are saved. 9. To add a DNS server to which the switch sends Internet on page 29. The Device Admin Password page displays. Configure Switch System 82 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 83
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register Map host names to DNS server IP addresses and display dynamic host mappings You can manually map host names to DNS server IP addresses and view dynamic host mappings. Add an
  • Netgear GS752TPPv3 | User Manual - Page 84
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed For more information, see Register the switch on page 32. Configure Switch System 84 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 85
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously of the following passwords: • Enter your device admin password. Configure Switch System 85 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 86
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app page displays. 5. Select System > Management > DNS > Host Configuration. Configure Switch System 86 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 87
    4 SFP Ports User Manual The Host Configuration page default, Universal Plug and Play (UPnP) and Simple Service Discovery Protocol (SSDP) are enabled on the switch. UPnP it. • NSDP: A NETGEAR device or application that supports NETGEAR Switch Discovery Protocol (NSDP) can discover the switch in
  • Netgear GS752TPPv3 | User Manual - Page 88
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To manage switch discovery protocols: 1. Connect your computer to the same network as the switch. You is purple and positioned to the right: Bonjour is enabled. Configure Switch System 88 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 89
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. In the NSDP Configuration section, click the Allow Discovery toggle to enable or disable NSDP: by the switch. • Inactive: The device is not mounted. Configure Switch System 89 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 90
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Invalid: The device is not present or an invalid device is plugged in. 6. To refresh the page, and processed by devices that are configured to receive LLDP. Configure Switch System 90 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 91
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual LLDP-MED is an enhancement to LLDP with the following features: • Autodiscovery of LAN System > LLDP > LLDP Configuration. The LLDP Configuration page displays. Configure Switch System 91 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 92
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. In the TLV Advertised Interval field, enter the interval in seconds at which the switch transmits LLDP of the switch in the address field of your web browser. Configure Switch System 92 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 93
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on- Refresh button. The following table describes the nonconfigurable fields on the page. Configure Switch System 93 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 94
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 18. LLDP-MED network policy information Field Network Policy Number Application VLAN ID VLAN Type network and not connected to the Internet on page 29. Configure Switch System 94 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 95
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to activate port ID is identical to the number of the interface Configure Switch System 95 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 96
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 19. LLDP local device information (Continued) Field Port Description Advertisement Description The table describes the nonconfigurable fields on the page. Configure Switch System 96 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 97
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 20. LLDP neighbor information Field MSAP Entry Local Port Chassis ID Subtype Chassis ID Port ID Subtype Port ID System Name Description The detected Media Service Access Point (MSAP) entry of the neighbor The number of
  • Netgear GS752TPPv3 | User Manual - Page 98
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 21. Detailed LLDP neighbor information (Continued) Field Port For example, 100BASE-TX full duplex mode. The system capabilities that are supported on the neighbor The system capabilities that are enabled on the neighbor The
  • Netgear GS752TPPv3 | User Manual - Page 99
    Ports User Manual Table 21. Detailed LLDP neighbor information (Continued) Field PoE Power Value Hardware Revision Firmware Revision Software Revision (latitude, longitude, and altitude) The neighbor's Emergency Call Service (ECS) Emergency Location Identification Number (ELIN) The neighbor's
  • Netgear GS752TPPv3 | User Manual - Page 100
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 21. Detailed LLDP neighbor information (Continued) Field DSCP You can configure SNMP settings for SNMPv1, SNMPv2, and SNMPv3. The switch supports the configuration of SNMP groups and users that can manage traps that the SNMP
  • Netgear GS752TPPv3 | User Manual - Page 101
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you ReadWrite: The community can both read and write (save) information. Configure Switch System 101 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 102
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. From the Status menu, select to enable or disable the community: • Disabled: The community button. The Edit Community Configuration pop-up window displays. Configure Switch System 102 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 103
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Change the settings as needed. For more information about the settings, see Add an SNMPv1 and button. Your settings are saved and the community is deleted. Configure Switch System 103 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 104
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Manage the SNMPv1 and SNMPv2 trap settings For each SNMP community, you can specify the source SNMPv1 to send traps to the receiver. This the default setting. Configure Switch System 104 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 105
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • SNMPv2: The switch uses SNMPv2 to send traps to the receiver. 9. In the Community String field page 31. 4. Click the Login button. The Dashboard page displays. Configure Switch System 105 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 106
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select System > Protocols > SNMP > Trap Configuration. The Trap Configuration page displays. 6. 5. Select System > Protocols > SNMP > Trap Configuration. Configure Switch System 106 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 107
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Trap Configuration page displays. 6. Select the check box for the trap configuration. 7. System > Protocols > SNMP > Trap Flags. The Trap Flags page displays. Configure Switch System 107 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 108
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual By default, all of the following trap flags are 7. Click the Apply button. Your settings are saved. Display the supported MIBs To display the MIBs that are supported by the switch: 1. Connect your computer to the same network as
  • Netgear GS752TPPv3 | User Manual - Page 109
    + Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device UI on page 31. 4. Click the Login button. The Dashboard page displays. 5. Select System > Protocols > SNMP > Supported MIBs. The Supported MIBs page displays. The Name field displays
  • Netgear GS752TPPv3 | User Manual - Page 110
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select System > Protocols > SNMP > SNMP V3. The SNMP V3 page displays. The network and not connected to the Internet on page 29. Configure Switch System 110 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 111
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the default is 4. 10. Click the Apply button. Your settings are saved. Configure Switch System 111 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 112
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual HTTPS management access You can configure secure HTTP (HTTPS) access to the device UI. Configure HTTPS session over a web browser. This is the default setting. Configure Switch System 112 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 113
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • The toggle is purple and positioned to the right: You switch is preconfigured with a self-signed SSL certificate for HTTPS access. The switch supports a single certificate. You can generate a new certificate on the switch. You
  • Netgear GS752TPPv3 | User Manual - Page 114
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To let the switch generate an SSL certificate: 1. Connect your computer to the same network as the SSL security certificate file on the switch on page 539. Configure Switch System 114 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 115
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Before you transfer a file from a server to the switch, be sure that the following conditions are true Type menu, select the type of SSL certificate to download: Configure Switch System 115 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 116
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • SSL Trusted Root Certificate PEM File: SSL Trusted Root Certificate file (PEM Encoded) • SSL Server Certificate PEM in to the device UI over an HTTPS session. Configure Switch System 116 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 117
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To delete the SSL certificate: 1. Connect your computer to the same network as the switch. ) link, in which x.x.x.x represents the IP address of the switch. Configure Switch System 117 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 118
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Apple Safari: Click the Show Details button. Then, click the visit this website link. If a warning For more information, see Register the switch on page 32. Configure Switch System 118 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 119
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your Adelman (RSA) key. The switch is preconfigured with an RSA key for SSH access. The switch supports a single RSA key. You can generate a new RSA key on the switch. You can
  • Netgear GS752TPPv3 | User Manual - Page 120
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Generate an RSA key The switch is preconfigured with an RSA key. You can let the switch generate Key Present field shows Yes, indicating that the key is present. Configure Switch System 120 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 121
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Transfer an RSA key from a computer to the switch You can transfer an RSA key file from during the transfer and upon successful completion of the transfer. Configure Switch System 121 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 122
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Delete the RSA key Note: To delete the RSA key file, SSH must be disabled (see Configure the Keys radio button. 7. Click the Apply button. The RSA key is removed. Configure Switch System 122 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 123
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure inbound Telnet settings If you enable the inbound Telnet session capability, an authorized user 7. Click the Apply button. Your settings are saved. Configure Switch System 123 Settings User Manual
  • Netgear GS752TPPv3 | User Manual - Page 124
    3 Manage VLANs This chapter covers the following topics: • Manage the VLAN configuration on the switch • Auto-VLANs • Configure a MAC-based VLAN • Configure a protocol-based VLAN group • Configure Generic Attribute Registration Protocol • Private VLANs • Protect ports Note: For more information
  • Netgear GS752TPPv3 | User Manual - Page 125
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Manage the VLAN configuration on the switch You can add, change, and delete VLANs, or reset the entire VLAN configuration on the switch to defaults. About VLANs Adding virtual LAN (VLAN) support to a Layer 2 switch offers some of the
  • Netgear GS752TPPv3 | User Manual - Page 126
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual By default, none of the four Auto VLANs include as members any interfaces or LAGs. Interfaces and LAGs are displays. 7. In the VLAN ID field, type the identifier for the new VLAN. Manage VLANs 126 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 127
    be up to 32 characters, including blanks. 9. Click the Save button. Your setting are saved and the VLAN is added. Note: When you add a VLAN manually (as in this procedure), the VLAN Type field always shows Static. A VLAN that is created by GVRP registration initially uses a type of dynamic but you
  • Netgear GS752TPPv3 | User Manual - Page 128
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Switching > VLAN > VLAN Configuration (Basic). The VLAN Configuration (Basic) page displays. 6. From the VLAN PVID) for all ports or LAGs. All ports or LAGs display a "P." Manage VLANs 128 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 129
    Type Definition The name for the VLAN The type of the VLAN you selected: • Default (VLAN ID = 1): Always present • Static: A VLAN that you added manually or the Auto-WiFi, Auto-Camera, Auto-VoIP, or Auto-Video VLAN • Dynamic: A VLAN that was created through GVRP registration and that you did not
  • Netgear GS752TPPv3 | User Manual - Page 130
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For more Access the switch off-network and not connected to the Internet on page 29. Manage VLANs 130 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 131
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to frames. • GVRP is disabled on all ports and all dynamic entries are cleared. Manage VLANs 131 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 132
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To reset the entire VLAN configuration to default settings: 1. Connect your computer to the same network as . All VLANs, except for the default VLAN and the Auto VLANs, are deleted. Manage VLANs 132 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 133
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change the port VLAN ID (PVID) settings By default, each interface is assigned a port VLAN ID (PVID) of number (for example, g5) in the Search field and click the Go button. Manage VLANs 133 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 134
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • To configure multiple interfaces with the same settings, select the check box associated with each interface. • VLAN is the port VLAN ID of the interface that receives this frame. Manage VLANs 134 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 135
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 14. In the Port Priority field, set the default 802.1p so that they can be prioritized above data packets in order to provide better Quality of Service (QoS). For example, you can enable a voice VLAN on an interface that is
  • Netgear GS752TPPv3 | User Manual - Page 136
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and tagged voice traffic. • Dot1p: Configure voice VLAN 802.1p priority tagging for voice traffic. Manage VLANs 136 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 137
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you select this mode, enter the dot1p value in the the prioritization for the level of Quality of Service (QoS) that is suitable for the type of device that the VLAN supports. The switch comes preconfigured with the following
  • Netgear GS752TPPv3 | User Manual - Page 138
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Auto-Video: The switch places detected video devices in the Auto-Video VLAN. Except for the Auto -VLAN page displays. The following steps refer to the OUI-based Properties section. Manage VLANs 138 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 139
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Change the OUI-based properties for the Auto VLANs as needed: • Auto-VoIP VLAN: - To change the connected to the Internet on page 29. The Device Admin Password page displays. Manage VLANs 139 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 140
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For is disabled. This is the default setting. • Enable: The Auto WiFi mode is enabled. Manage VLANs 140 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 141
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. From the Auto Camera Mode menu, select the Auto Camera mode for the interface to identify a WiFi device, camera, or VoIP phone on the network. The switch supports up to 32 OUIs. Manage VLANs 141 User
  • Netgear GS752TPPv3 | User Manual - Page 142
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add an OUI: 1. Connect your computer to the same network as the switch. You can use a WiFi . • Auto-Camera: The OUI is for a camera. • Auto-VoIP: The OUI is for a VoIP phone. Manage VLANs 142 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 143
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. Click the Save button. Your settings are saved and the OUI is added to the OUI Table section. button. Your settings are saved and the OUI is removed from the OUI Table section. Manage VLANs 143 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 144
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure the global protocol-based VoIP prioritization and class Voice over can be prioritized above data packets in order to provide better Quality of Service (QoS). With the Auto-VoIP feature, voice prioritization can be provided
  • Netgear GS752TPPv3 | User Manual - Page 145
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Prioritization Type menu, select the prioritization type: • Traffic Class: Incoming traffic is assigned displays. For more information, see Register the switch on page 32. Manage VLANs 145 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 146
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the saved. The Operational Status field shows if the interface is up or down. Manage VLANs 146 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 147
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display the Auto-VoIP status To display the Auto-VoIP status: 1. Connect your computer to the Refresh button. The following table describes the nonconfigurable fields on the page. Manage VLANs 147 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 148
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 24. Auto-VoIP status information Field Auto-VoIP VLAN ID Maximum Number of Voice Channels Supported Number of Voice Channels Detected Description The Auto-VoIP VLAN ID (By default, 4088) The maximum number
  • Netgear GS752TPPv3 | User Manual - Page 149
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to warranty page displays. For more information, see Register the switch on page 32. Manage VLANs 149 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 150
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed 3. Enter one of the following passwords: • Enter your device admin password. Manage VLANs 150 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 151
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, automatically. Add a protocol-based VLAN group You can add a protocol-based VLAN group. Manage VLANs 151 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 152
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add a protocol-based VLAN group: 1. Connect your computer with the group: • IP: IP is a network layer protocol that provides a connectionless service for the delivery of data. • ARP: Address Resolution Protocol (ARP) is a
  • Netgear GS752TPPv3 | User Manual - Page 153
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • IPX: The internetwork packet exchange (IPX) is a connectionless datagram network-layer protocol that forwards data of the following passwords: • Enter your device admin password. Manage VLANs 153 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 154
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the Insight network the switch off-network and not connected to the Internet on page 29. Manage VLANs 154 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 155
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to activate to the Internet on page 29. The Device Admin Password page displays. Manage VLANs 155 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 156
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For more GVRP is enabled, the switch can share VLAN IDs with devices in the network. Manage VLANs 156 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 157
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure GARP switch settings: 1. Connect your computer to the same network as the switch. You can use a These settings take effect only if the GVRP mode is enabled on the switch. Manage VLANs 157 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 158
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure GARP settings an interface: 1. Connect your computer to the same network as the switch. Click the Edit button. The Edit GARP Port Configuration pop-up window displays. Manage VLANs 158 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 159
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. From the GVRP Mode menu, select to enable or disable time for another station to assert registration for the same attribute to maintain uninterrupted service. Enter a number between 20 and 600 (0.2 to 6.0 seconds). The default
  • Netgear GS752TPPv3 | User Manual - Page 160
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Secondary VLAN: The secondary VLAN ID differentiates subdomains private VLAN, you can configure multiple community VLANs. Within a private VLAN, the switch supports two types of special port designations: • Host port: The port is a host
  • Netgear GS752TPPv3 | User Manual - Page 161
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual A port must be in the correct port mode to participate in a private VLAN. For example, to make a port , see Credentials for the device UI on page 31. 4. Click the Login button. Manage VLANs 161 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 162
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Switching > VLAN > Private VLAN > VLAN Type Configuration. The VLAN Type Configuration page and not connected to the Internet on page 29. Manage VLANs 162 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 163
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to activate the private VLAN, see Assign a private VLAN type to a VLAN on page 161. Manage VLANs 163 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 164
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. Click the Save button. Your settings are saved. The following table describes the nonconfigurable information on page 31. 4. Click the Login button. The Dashboard page displays. Manage VLANs 164 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 165
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Switching > VLAN > Private VLAN > VLAN Association Configuration. The VLAN Association Configuration Mode Configuration. The VLAN Port Mode Configuration page displays. Manage VLANs 165 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 166
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports and LAGs VLANs on page 169. 10. Click the Save button. Your settings are saved. Manage VLANs 166 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 167
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Private VLAN host interface: Assign the interface to primary and secondary VLANs If you configure the private number (for example, g5) in the Search field and click the Go button. Manage VLANs 167 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 168
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • To configure multiple interfaces with the same settings, select the check box associated with each interface page displays. For more information, see Register the switch on page 32. Manage VLANs 168 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 169
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the interface to a single primary VLAN and to one or more secondary VLANs. Manage VLANs 169 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 170
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To assign a private VLAN promiscuous interface to a primary VLAN and secondary VLANs: 1. Connect your computer to the private VLAN port mode on page 165). 8. Click the Edit button. Manage VLANs 170 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 171
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Edit Private VLAN Promiscuous Interface Configuration pop-up window displays. 9. In the Promiscuous Primary VLAN field, off-network and not connected to the Internet on page 29. Manage VLANs 171 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 172
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to as protected. A port that is not configured as protected is an unprotected port. Manage VLANs 172 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 173
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure protected ports: 1. Connect your computer to the same network as the switch. You can use button to select all ports. 7. Click the Apply button. Your settings are saved. Manage VLANs 173 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 174
    4 Configure Switching This chapter covers the following topics: • LLDP and LLDP-MED settings for interfaces • Power over Ethernet • Green Ethernet settings • Configure the port settings and maximum frame size • Link aggregation groups • Spanning Tree Protocol • MAC address table • DHCP snooping •
  • Netgear GS752TPPv3 | User Manual - Page 175
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual LLDP and LLDP-MED settings for interfaces This section describes functions are disabled on all interfaces. LLDP-MED is an enhancement to LLDP with support for the following features: • Auto-discovery of LAN policies (such as VLAN,
  • Netgear GS752TPPv3 | User Manual - Page 176
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page The interface advertises the management IP address. This is the default setting. Configure Switching 176 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 177
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Stop Advertise: The interface does not advertise the management IP address. 10. From the 3. Enter one of the following passwords: • Enter your device admin password. Configure Switching 177 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 178
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter about VLANs: • Disabled: The interface does not transmit network policy TLVs. Configure Switching 178 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 179
    Ports Individual Port GS728TPv3 24 190W 30W (802.3at) GS728TPPv3 24 380W 30W (802.3at) GS752TPv3 48 380W 30W (802.3at) GS752TPPv3 48 720W 30W (802.3at) Supplied power is prioritized higher-priority, lower-numbered PoE ports are supported first. Configure Switching 179 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 180
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Although a device might be listed as an 802.3at PoE+-powered device, it might not require the Port 1 delivers 4.4W to a PD. The available power budget is 185.6W (190W-4.4W). Configure Switching 180 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 181
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual An example for model GS752TPPv3: A Class 4 PD is attached to Port 1, a Class 2 PD to Port 2, and another the switch, as opposed to settings that apply to individual ports. Configure Switching 181 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 182
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure global PoE settings: 1. Connect your computer to page displays. 6. In the PoE Configuration section, click the check box for the PoE firmware version. 7. Click the Edit button. The Edit PoE Configuration pop-up window displays.
  • Netgear GS752TPPv3 | User Manual - Page 183
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. To set the traps, in the PoE Trap Configuration section section. Table 28. PoE configuration information Field Description Firmware Version The firmware version of the PoE software Power Status The power
  • Netgear GS752TPPv3 | User Manual - Page 184
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For by the switch exceeds the total power budget. (In such a situation, the Configure Switching 184 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 185
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual switch might not be able to deliver power to all connected devices.) If the same IEEE 802: The port performs a 4-point resistive detection. This is the default setting. Configure Switching 185 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 186
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • 4pt 802.3af + Legacy: The port performs a 4-point PoE port information Field High Power Max Power (mW) Class Description All ports supports high power mode The maximum power in milliwatts (mW) that can be provided
  • Netgear GS752TPPv3 | User Manual - Page 187
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual After you associate a timer schedule with a PoE port, the start date and time force the > POE > Timer Schedule. The Timer Schedule page displays. 6. Click the Add New button. Configure Switching 187 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 188
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Add Timer Schedule pop-up window displays. 7. Do one of the following: • Add a new monthly basis. Note: A timer schedule can contain both periodic and absolute entries. Configure Switching 188 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 189
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add a new PoE timer schedule with a periodic entry or add a new periodic entry to an existing timer timer schedule. The following steps add an entry to the timer schedule. Configure Switching 189 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 190
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. From the Type menu, select Period. The window adjusts. 9. Click in the Date Start field to display 0, then the schedule is triggered only once. 14. Click the Save button. Configure Switching 190 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 191
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Either the new timer schedule and entry are added to the same ID number because the timer schedule tracks continuous and periodic entries separately. Configure Switching 191 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 192
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Click the Edit button. The Edit Timer Schedule pop-up window displays. 9. Change the . 5. Select Switching > POE > Timer Schedule. The Timer Schedule page displays. Configure Switching 192 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 193
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Click the name of the timer schedule to which the existing entry is associated. The displays. 5. Select Switching > POE > Timer Schedule. The Timer Schedule page displays. Configure Switching 193 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 194
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Select the check box for the timer schedule. 7. Click the Delete button. Your . 5. Select Switching > Green Ethernet. The Green Ethernet Configuration page displays. Configure Switching 194 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 195
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Click the Auto Power Down Mode toggle: • The enabled. EEE combines the MAC address of a port with a family of physical layers that support operation in a low power mode. (EEE is defined by the IEEE 802.3az standard.) Lower
  • Netgear GS752TPPv3 | User Manual - Page 196
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your combines the MAC address of the interface with a family of physical layers that support operation in a low power Configure Switching 196 User
  • Netgear GS752TPPv3 | User Manual - Page 197
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual mode. (EEE is defined by the IEEE 802.3az standard.) Lower power mode lets both the send Insight app, enter the Insight network password for the last Insight network location. Configure Switching 197 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 198
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device Frame Size field, specify the maximum Ethernet frame size that any interface can support. The frame size includes Ethernet header, CRC, and payload. The range is
  • Netgear GS752TPPv3 | User Manual - Page 199
    mode for the port. • Disable: Port speed is not automatically negotiated. • Enable: Port speed is automatically negotiated. This is the default setting. 13. To manually set the speed for the port, in the Speed field, type one of the following options: • Auto: The speed is set by the auto-negotiation
  • Netgear GS752TPPv3 | User Manual - Page 200
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual the packets on the port exceeds a preconfigured threshold and responds does not require a partner system to be able to aggregate its member ports. The switch supports static LAGs. When a port is added as a static member to a LAG, the
  • Netgear GS752TPPv3 | User Manual - Page 201
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The switch supports 16 LAGs with names ch1 through ch16. Configure a LAG You can group one or more full- LAGs with the same settings, select the check box in the heading row. Configure Switching 201 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 202
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 7. Click the Edit button. The Edit LAG Configuration pop-up window displays. 8. To change the default LAG. • Enable: STP is enabled for the LAG. This is the default setting. Configure Switching 202 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 203
    Static: Disables Link Aggregation Control Protocol (LACP) on the LAG. You must configure the LAG manually on each device. This is the default setting. • LACP: Enables LACP on the LAG. If both devices support LACP, the LAG can be configured automatically between the devices. 15. Click the Save button
  • Netgear GS752TPPv3 | User Manual - Page 204
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For the IP address of the switch in the address field of your web browser. Configure Switching 204 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 205
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and browser and enter the IP address of the switch in the address field of your web browser. Configure Switching 205 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 206
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and -out period is long. This is the default setting. • Short: The time-out period is short. Configure Switching 206 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 207
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If the switch does not receive a LACP protocol data unit the global STP settings and display the STP status on page 208. The switch support the following spanning tree versions: • CST: Common STP. For information about
  • Netgear GS752TPPv3 | User Manual - Page 208
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Note: For two bridges to be in the same region, the force version must be 802.1s and their . This indicates that STP is enabled on the switch, which is the default setting. Configure Switching 208 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 209
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. If the Spanning Tree State toggle is gray and positioned to the left, which indicates that STP is Change Count The number of times that the topology changed for the CST Configure Switching 209 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 210
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 32. STP configuration and status information (Continued) Field Topology Change Designated Root Root one of the following passwords: • Enter your device admin password. Configure Switching 210 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 211
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the Insight discarded. The range is from 6 to 40 hops. The default is 20 hops. Configure Switching 211 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 212
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. Click the Apply button. Your settings are saved. The following table describes the 3. Enter one of the following passwords: • Enter your device admin password. Configure Switching 212 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 213
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter : The interface forwards BPDUs even when STP is disabled on the interface. Configure Switching 213 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 214
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 12. From the Auto Edge menu, select if the interface can become an edge port: • settings are saved. The following table describes the nonconfigurable fields on the page. Configure Switching 214 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 215
    : The interface is currently in the forwarding mode. The interface can forward traffic and learn new MAC addresses • Manual forwarding: The interface is currently in the manual forwarding mode. The interface can forward traffic and learn new MAC addresses Port ID Hello Timer The port identifier
  • Netgear GS752TPPv3 | User Manual - Page 216
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the port's link is a point-to-point link (True) or not or (False) Configure Switching 216 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 217
    : The interface is currently in the forwarding mode. The interface can forward traffic and learn new MAC addresses. • Manual forwarding: The interface is currently in the manual forwarding mode. The interface can forward traffic and learn new MAC addresses Display the Rapid STP interface status You
  • Netgear GS752TPPv3 | User Manual - Page 218
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously Master, or Disabled. The spanning tree operation mode: STP, RSTP, or MSTP Configure Switching 218 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 219
    : The interface is currently in the forwarding mode. The interface can forward traffic and learn new MAC addresses. • Manual forwarding: The interface is currently in the manual forwarding mode. The interface can forward traffic and learn new MAC addresses Manage MST instances You can add, change
  • Netgear GS752TPPv3 | User Manual - Page 220
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously button. The following table describes the nonconfigurable fields on the page. Configure Switching 220 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 221
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 37. MST configuration information Field Description Bridge Identifier The bridge identifier for the MST credentials, see Credentials for the device UI on page 31. Configure Switching 221 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 222
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Switching > STP > MSTP > MST Configuration. The 31. 4. Click the Login button. The Dashboard page displays. Configure Switching 222 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 223
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Switching > STP > MSTP > MST Configuration. The MST Configuration page displays. 6. Select the check box that an MST instance and display the MST status on page 219. Configure Switching 223 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 224
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 7. From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports and , which is created by using the port priority and the interface number Configure Switching 224 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 225
    : The interface is currently in the forwarding mode. The interface can forward traffic and learn new MAC addresses. • Manual forwarding: The interface is currently in the manual forwarding mode. The interface can forward traffic and learn new MAC addresses. Port Role Designated Root Designated Cost
  • Netgear GS752TPPv3 | User Manual - Page 226
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 38. MST interface configuration information (Continued) Field Designated Bridge Designated Port Dashboard page displays. 5. Select Switching > STP > STP Statistics. Configure Switching 226 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 227
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The STP Statistics page displays. 6. From the Filter By menu, select to display ports only (Ports), LAGs IP address of the switch in the address field of your web browser. Configure Switching 227 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 228
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and connected or Access the switch off-network and not connected to the Internet on page 29. Configure Switching 228 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 229
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Refresh button. The following table describes the nonconfigurable fields on the page. Configure Switching 229 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 230
    used • Management: The management MAC address Add a static MAC address to the MAC address table Static MAC address entries are the ones that you manually add to the MAC address table for a specific interface and VLAN. To add a static MAC address to the MAC address table: 1. Connect your computer
  • Netgear GS752TPPv3 | User Manual - Page 231
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the page displays. For more information, see Register the switch on page 32. Configure Switching 231 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 232
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the the switch You can globally enable DHCP snooping for the switch. Configure Switching 232 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 233
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To globally enable DHCP snooping for the switch: 1. Connect your computer to the same network as the switch an untrusted interface to verify that the MAC address and the DHCP Configure Switching 233 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 234
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual client hardware address match. If the addresses do not match, the switch drops the packet. 8. 7. Click the Edit button. The Edit VLAN Configuration pop-up window displays. Configure Switching 234 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 235
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. From the DHCP Snooping Mode menu, select the DHCP snooping mode for the VLAN Switching > DHCP Snooping > Interface Configuration. The Interface Configuration page displays. Configure Switching 235 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 236
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports and the burst interval is also not applicable, and rate limiting is disabled. Configure Switching 236 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 237
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 12. In the Burst Interval (secs) field, type the burst interval in seconds for > Binding Configuration. The Binding Configuration page displays. 6. Click the Add New button. Configure Switching 237 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 238
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Add Static Binding Configuration pop-up window displays. 7. From the Interface menu, select the interface. Internet on page 29. The Device Admin Password page displays. Configure Switching 238 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 239
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For page displays. For more information, see Register the switch on page 32. Configure Switching 239 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 240
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed messages filtered by the DHCP snooping feature on untrusted interfaces. Configure Switching 240 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 241
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display or clear the DHCP snooping statistics: 1. Connect your computer to the same network the Refresh button. The following table describes the DHCP snooping statistics. Configure Switching 241 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 242
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 41. DHCP Snooping Statistics information Field Description MAC Verify Failures The number of DHCP messages off-network and not connected to the Internet on page 29. Configure Switching 242 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 243
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to activate switch off-network and not connected to the Internet on page 29. Configure Switching 243 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 244
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to suboption is enabled. 11. Click the Save button. Your settings are saved. Configure Switching 244 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 245
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure a DHCP L2 relay interface You can enable a DHCP L2 relay on an interface. To configure DHCP with the same settings, select the check box in the heading row. Configure Switching 245 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 246
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Click the Edit button. The Edit DHCP L2 Relay Configuration pop-up window displays. 9. From the see Credentials for the device UI on page 31. 4. Click the Login button. Configure Switching 246 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 247
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Switching > DHCP L2 Relay > DHCP L2 Relay Interface Statistics. The useful when hosts configure static IP addresses, the switch cannot Configure Switching 247 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 248
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual run DHCP snooping, or other switches in the network do not run dynamic ARP inspection. A static left: Source MAC addresses are not validated. This is the default setting. Configure Switching 248 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 249
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • The toggle is purple and positioned to the right: Source MAC addresses are validated for ARP . 3. Enter one of the following passwords: • Enter your device admin password. Configure Switching 249 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 250
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the DHCP snooping database. 12. Click the Save button. Your settings are saved. Configure Switching 250 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 251
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure a DAI interface You can configure one or more dynamic ARP inspection (DAI) interfaces. To configure a the same settings, select the check box in the heading row. Configure Switching 251 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 252
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Click the Edit button. The Edit DAI Interface Configuration pop-up window displays. 9. Form the Trust (DAI) access control list (ACL) to which you then can add rules. Configure Switching 252 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 253
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add a DAI ACL: 1. Connect your computer to the same network as the switch. You can use a it. A DAI ACL rule consists of a binding between an IP address and a MAC address. Configure Switching 253 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 254
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure a rule for an existing DAI ACL: 1. Connect your computer to the same network as the switch . Click the Save button. Your settings are saved and the rule is added. Configure Switching 254 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 255
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Remove a rule from a DAI ACL You can remove a rule from a DAI ACL if you no longer need the rule no longer need. All rules that are associated with the ACL are also removed. Configure Switching 255 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 256
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To remove a DAI ACL: 1. Connect your computer to the same network as the switch. You can use a enter the IP address of the switch in the address field of your web browser. Configure Switching 256 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 257
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and ARP reply packets did not match the destination MAC address in the Ethernet header Configure Switching 257 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 258
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 43. DAI Statistics information (Continued) Field Invalid IP Forwarded Dropped Description The number of by DAI The number of invalid ARP packets dropped by DAI Configure Switching 258 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 259
    5 Configure Multicast This chapter covers the following topics: • Display the entries in the multicast forwarding database • Display the multicast forwarding database statistics • Internet Group Management Protocol snooping • IGMP snooping querier overview • Multicast Listener Discovery snooping •
  • Netgear GS752TPPv3 | User Manual - Page 260
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display the entries in the multicast forwarding database The multicast forwarding database (MFDB) holds match is required. 7. To refresh the page, click the Refresh button. Configure Multicast 260 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 261
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The following table describes the nonconfigurable fields in IGMP Snooping Table section on the page. displays. For more information, see Register the switch on page 32. Configure Multicast 261 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 262
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously is received, the switch forwards a copy into each of the remaining network Configure Multicast 262 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 263
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual segments in accordance with the IEEE MAC Bridge standard. Eventually duplex links. Allowing switches to snoop IGMP packets is a creative solution to this problem. The switch uses the information in the IGMP packets as they are being
  • Netgear GS752TPPv3 | User Manual - Page 264
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Switching > Multicast > IGMP Snooping > IGMP Snooping. The IGMP one of the following passwords: • Enter your device admin password. Configure Multicast 264 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 265
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the and VLANs that are enabled for IGMP snooping and IGMP snooping querier. Configure Multicast 265 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 266
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the IGMP statistics and VLAN information: 1. Connect your computer to the same network as the for IGMP The interfaces on which IGMP snooping is enabled Snooping Configure Multicast 266 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 267
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 47. IGMP snooping statistics (Continued) Field Description VLAN IDs Enabled For Snooping Interface Configuration. The IGMP Snooping Interface Configuration page displays. Configure Multicast 267 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 268
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Filter By menu, select to display ports only (Ports), LAGs only (LAG), or both ports , which means that the time-out is disabled and the switch waits indefinitely. Configure Multicast 268 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 269
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 14. Click the Save button. Your settings are saved. Configure IGMP snooping for a VLAN You can Edit button. The Edit IGMP Snooping VLAN Configuration pop-up window displays. Configure Multicast 269 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 270
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. From the Admin Mode menu, select to enable or disable IGMP snooping for the VLAN: • Disabled: Disabled: Query Mode is disabled for the VLAN. This is the default setting. Configure Multicast 270 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 271
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If querier mode is disabled, the switch does not send IGMP queries and cannot determine if any warranty page displays. For more information, see Register the switch on page 32. Configure Multicast 271 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 272
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously IGMP packets to the multicast router that is connected to the interface. Configure Multicast 272 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 273
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual In most situations, this configuration is not required because the switch automatically detects a multicast option is disabled for the VLAN. This is the default setting. Configure Multicast 273 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 274
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Enabled: The IGMP multicast router option is enabled for the VLAN. 10. Click the Save button 32. 3. Enter one of the following passwords: • Enter your device admin password. Configure Multicast 274 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 275
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the Insight VLAN You can add an IGMP querier for use with a VLAN on the network. Configure Multicast 275 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 276
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add an IGMP snooping querier for a VLAN: 1. Connect your computer to the same network as the switch. source IP address in periodic IGMP queries that are sent on the VLAN. Configure Multicast 276 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 277
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. Click the Save button. Your settings are saved. Change an IGMP snooping querier for a VLAN You an IGMP snooping querier for a VLAN on page 275. 9. Click the Save button. Configure Multicast 277 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 278
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Remove the IGMP snooping querier settings from a VLAN You can remove the IGMP snooping querier settings are removed. (The VLAN itself is not deleted.) Configure Multicast 278 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 279
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display the status of the IGMP snooping querier for all VLANs You can display the the Refresh button. The following table describes the nonconfigurable fields on the page. Configure Multicast 279 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 280
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 48. IGMP snooping group information Field VLAN ID Operational State Description The VLAN ID on page displays. For more information, see Register the switch on page 32. Configure Multicast 280 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 281
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously messages, identified in IPv6 packets by a preceding Next Header value of 58. Configure Multicast 281 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 282
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Enable MLD snooping You can enable MLD snooping for the switch. MLD snooping is used to button. Your settings are saved. 8. To refresh the page, click the Refresh button. Configure Multicast 282 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 283
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The following table describes the nonconfigurable fields on the page. Table 49. MLD snooping configuration the credentials, see Credentials for the device UI on page 31. Configure Multicast 283 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 284
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Switching > Multicast > MLD Snooping > Interface the time-out is disabled and the switch waits indefinitely. Configure Multicast 284 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 285
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 13. From the Fast Leave Mode menu, select to enable or disable the MLD snooping Multicast > MLD Snooping > MLD VLAN Configuration. The MLD VLAN Configuration page displays. Configure Multicast 285 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 286
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Click the Add New button. The Add MLD VLAN Configuration pop-up window displays. 7. In the VLAN enter the IP address of the switch in the address field of your web browser. Configure Multicast 286 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 287
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and browser and enter the IP address of the switch in the address field of your web browser. Configure Multicast 287 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 288
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and want to make sure that the multicast router always receives MLD packets from the switch. Configure Multicast 288 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 289
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure an MLD multicast router interface: 1. Connect your computer to the same network as Edit button. The Edit Multicast Router Configuration pop-up window displays. Configure Multicast 289 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 290
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. From the Multicast Router menu, select to enable or disable the MLD multicast router option for the Credentials for the device UI on page 31. 4. Click the Login button. Configure Multicast 290 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 291
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Switching > Multicast > MLD Snooping > Multicast Router VLAN Configuration. The on the switch and configure the global settings. Configure Multicast 291 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 292
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To enable the MLD snooping querier and configure the global when no address is configured on the VLAN on which queries are sent. The supported IPv6 formats are x:x:x:x:x:x:x:x and x::x. Note: The MLDP Version field always states MLD
  • Netgear GS752TPPv3 | User Manual - Page 293
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. In the Query Interval field, type the period in seconds between periodic queries sent by the snooping on page 31. 4. Click the Login button. The Dashboard page displays. Configure Multicast 293 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 294
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Switching > Multicast > MLD Snooping > Querier VLAN Configuration. The Querier VLAN Configuration page displays. querier from which a query was snooped on the VLAN Configure Multicast 294 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 295
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 50. MLD snooping querier VLAN configuration information (Continued) Field Description Last Querier Select the check box for the VLAN. 7. Click the Edit button. Configure Multicast 295 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 296
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Edit MLD Snooping Querier VLAN Configuration pop-up window displays. 8. Change the settings as displays. 6. Select the check box for the VLAN. 7. Click the Delete button. Configure Multicast 296 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 297
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved and the MLD snooping querier settings are removed. (The VLAN itself is 32. 3. Enter one of the following passwords: • Enter your device admin password. Configure Multicast 297 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 298
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter are saved. The following table describes the nonconfigurable fields on the page. Configure Multicast 298 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 299
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 51. MVR configuration information Field MVR Max Multicast Groups MVR Current Multicast Groups Definition The maximum number of multicast groups that MVR supports The number of the MVR groups allocated Add an MVR group
  • Netgear GS752TPPv3 | User Manual - Page 300
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Add MVR Group Configuration pop-up window displays. 7. In the MVR Group IP field, type the 32. 3. Enter one of the following passwords: • Enter your device admin password. Configure Multicast 300 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 301
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the see Credentials for the device UI on page 31. 4. Click the Login button. Configure Multicast 301 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 302
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Switching > MVR > MVR Interface Configuration. The MVR Interface Configuration receives a leave message. 12. Click the Save button. Configure Multicast 302 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 303
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Configure the members of an MVR group You can add or remove interfaces as a member of the MVR group. A selected LAG displays blue in the LAG table. Configure Multicast 303 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 304
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. Click the Apply button. Your settings are saved. Display the MVR statistics You can Refresh button. The following table describes the nonconfigurable fields on the page. Configure Multicast 304 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 305
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 53. MVR statistics information Field IGMP Query Received IGMP Report V1 Received IGMP Report IGMP packet receive failures The number of IGMP packet transmit failures Configure Multicast 305 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 306
    6 Manage Routing This chapter covers the following topics: • Routing concepts • IPv4 routing • IPv6 routing • Routing VLANs • Routing table, routes and route preferences • Address Resolution Protocol 306
  • Netgear GS752TPPv3 | User Manual - Page 307
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Routing concepts The switch supports IP routing. When a packet enters the switch, the switch checks the destination MAC address to determine if it matches any of the configured routing interfaces.
  • Netgear GS752TPPv3 | User Manual - Page 308
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight is not supplied by the transport layer protocol The maximum number of hops supported by the switch Display the IPv4 routing statistics You can display the IPv4 routing statics
  • Netgear GS752TPPv3 | User Manual - Page 309
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the IPv4 routing statistics for the switch: 1. Connect your computer to the same network as to-live exceeded, errors discovered in processing their IP options, and so on Manage Routing 309 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 310
    PoE+ Smart Switches with 4 SFP Ports User Manual Table 55. IP statistics information (Continued) Field any datagrams counted in ipForwDatagrams. The number of output IP datagrams for which no problem was encountered to prevent their transmission to their destination, but that were discarded for
  • Netgear GS752TPPv3 | User Manual - Page 311
    PoE+ Smart Switches with 4 SFP Ports User Manual Table 55. IP statistics information (Continued) Field received The number of ICMP time exceeded messages received The number of ICMP parameter problem messages received The number of ICMP source quench messages received The number of ICMP redirect
  • Netgear GS752TPPv3 | User Manual - Page 312
    Smart Switches with 4 SFP Ports User Manual Table 55. IP statistics information (Continued) unreachable messages sent The number of ICMP time exceeded messages sent The number of ICMP parameter problem messages sent The number of ICMP source quench messages sent The number of ICMP redirect messages
  • Netgear GS752TPPv3 | User Manual - Page 313
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and browser and enter the IP address of the switch in the address field of your web browser. Manage Routing 313 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 314
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and connected on the network. DHCPv6 Client Mode can be enabled for only one VLAN on the switch. Manage Routing 314 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 315
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. From the Stateless Address AutoConfig Mode menu, select to enable or disable the stateless address automatic The range is from 4 to 1800 seconds. The default is 600 seconds. Manage Routing 315 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 316
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 17. From the Adv Managed Config Flag menu, select to enable or disable the router advertisement " saved. The following table describes the nonconfigurable fields on the page. Manage Routing 316 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 317
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 56. IPv6 VLAN configuration information Field Admin Mode Operational Mode Link State 5. Select Routing > IPv6 > Prefix Configuration. The Prefix Configuration page displays. Manage Routing 317 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 318
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Interface menu, select the VLAN. The IPv6 prefix configurations for the VLAN display. 7. Click Click the Save button. Your settings are saved and the prefix is added. Manage Routing 318 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 319
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Current State field displays the state of the IPv6 address: • TENT: The state is TENT ( 7. Select the check box for the IPv6 prefix configuration. 8. Click the Edit button. Manage Routing 319 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 320
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Edit IPv6 Prefix Configuration pop-up window displays. 9. Change the settings as needed. For menu, select the VLAN. The IPv6 prefix configurations for the VLAN display. Manage Routing 320 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 321
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 7. Select the check box for the IPv6 prefix configuration. 8. Click the Delete button. Your Refresh button. The following table describes the nonconfigurable fields on the page. Manage Routing 321 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 322
    Smart Switches with 4 SFP Ports User Manual Table 57. IPv6 statistics information Field Ip6InReceives frame did not carry enough data The number of input IPv6 datagrams for which no problems were encountered to prevent their continued processing, but that were discarded for reasons such as
  • Netgear GS752TPPv3 | User Manual - Page 323
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 57. IPv6 statistics information (Continued) Field Ip6OutDiscards Ip6OutNoRoutes Description The number of output IPv6 datagrams for which no problems were encountered to prevent their continued processing, but that were
  • Netgear GS752TPPv3 | User Manual - Page 324
    + Smart Switches with 4 SFP Ports User Manual Table 57. IPv6 statistics information (Continued) counter includes all those counted by icmpOutErrors. The number of ICMP messages not sent because of problems discovered within ICMP, such as a lack of buffers. This number does not include errors
  • Netgear GS752TPPv3 | User Manual - Page 325
    PoE+ Smart Switches with 4 SFP Ports User Manual Table 57. IPv6 statistics information (Continued) Too Big messages sent The number of ICMP Time Exceeded messages sent The number of ICMP Parameter Problem messages sent The number of ICMP Echo (request) messages sent The number of ICMP Echo Reply
  • Netgear GS752TPPv3 | User Manual - Page 326
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 57. IPv6 statistics information (Continued) Field Icmp6OutType136 Icmp6OutType143 Description The number of select one of the following methods to search for IPv6 neighbors: Manage Routing 326 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 327
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • IPv6 Address: Select IPv6 Address, and in the Search field, enter the 128-byte hexadecimal the field displays True. If the neighbor is not a router, the field displays False. Manage Routing 327 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 328
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 58. IPv6 Advanced Neighbor Table (Continued) Field Neighbor State Description The state of the neighbor displays. For more information, see Register the switch on page 32. Manage Routing 328 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 329
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed or less preferred than other static routes to the same destination. Manage Routing 329 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 330
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Use a value of 255 to indicate that the network is not reachable, preventing the route from the route. 7. Click the Edit button. The Edit Configure Routes pop-up window displays. Manage Routing 330 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 331
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Change the settings as needed. For more information about the settings, see Add a static IPv6 route 7. Click the Delete button. Your settings are saved. The route is removed. Manage Routing 331 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 332
    in the table: • All Routes: All active IPv6 routes. • Best Routes Only: The best active routes only, • Configured Routes Only: The manually configured routes only. 7. To refresh the page, click the Refresh button. The following table describes the nonconfigurable fields on the page. Manage Routing
  • Netgear GS752TPPv3 | User Manual - Page 333
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 59. IPv6 route table information Field IPv6 Prefix Prefix Length Protocol Next Hop Interface 32. 3. Enter one of the following passwords: • Enter your device admin password. Manage Routing 333 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 334
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Your settings are saved. Routing VLANs You can configure some interfaces to support VLANs and other interfaces to support routing. You can also configure the switch to allow traffic on a
  • Netgear GS752TPPv3 | User Manual - Page 335
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Create a routing VLAN with the VLAN static routing wizard The VLAN static routing wizard lets you create a VLAN ID field, type the VLAN ID that must be associated with the VLAN. Manage Routing 335 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 336
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The range is from 1 to 4093. 7. In the IP Address field, type the IPv4 address for the VLAN from all ports or LAGs. All ports or LAGs display blank. 11. Click the Apply button. Manage Routing 336 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 337
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Add routing to an existing VLAN and display routing VLAN information For an existing regular VLAN, that is, a VLAN that does not yet support routing, you can add an IPv4 routing address and associated
  • Netgear GS752TPPv3 | User Manual - Page 338
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. In the Subnet Mask field, type the associated routing subnet mask for the VLAN. 10. Click the 32. 3. Enter one of the following passwords: • Enter your device admin password. Manage Routing 338 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 339
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the 32. 3. Enter one of the following passwords: • Enter your device admin password. Manage Routing 339 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 340
    from multiple sources and list all routes: static routes, local routes, dynamically added routes, and so on. Static routes are routes that you manually add. The routing table can learn multiple routes to the same destination from multiple sources, for example dynamically added routes through routing
  • Netgear GS752TPPv3 | User Manual - Page 341
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For that is advertised by the VLAN is considered a valid router address by hosts. Manage Routing 341 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 342
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The period must be in the range from 1 to 9000 seconds. The default is 1800 seconds. 13 Routing > Routing Table. The Routing Table page displays. 6. Click the Add New button. Manage Routing 342 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 343
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Add Configure Routes pop-up window displays. 7. From the Route Type menu, select one of the following route types: • Static: Specify the network address,
  • Netgear GS752TPPv3 | User Manual - Page 344
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the routes: 1. Connect your computer to the same network as the switch. You can use a , or Default The type of route, depending on the protocol: Connected or Static Manage Routing 344 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 345
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 61. Routing table with route status information (Continued) Field Next Hop Address page displays. 5. Select Routing > Routing Table. The Routing Table page displays. Manage Routing 345 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 346
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Select the check box for the route. 7. Click the Edit button. The Edit Configure Routes pop page displays. 5. Select Routing > Routing Table. The Routing Table page displays. Manage Routing 346 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 347
    is used to translate an IP address to a media (MAC) address, defined by a LAN such as an Ethernet LAN. The switch support both a dynamic and manual ARP configuration. With manual ARP configuration, you can statically add entries into the ARP table. A device that sends IP packets must learn the MAC
  • Netgear GS752TPPv3 | User Manual - Page 348
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the ARP entries in the ARP cache: 1. Connect your computer to the same network as of a device on a subnet attached to one of the switch's existing routing interfaces. Manage Routing 348 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 349
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 62. ARP cache information (Continued) Field Port MAC for which the IP address is that of a router • Static: An ARP entry that was manually added • Dynamic: An ARP entry that was learned by the switch Age The time in seconds
  • Netgear GS752TPPv3 | User Manual - Page 350
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For enter the IP address of the switch in the address field of your web browser. Manage Routing 350 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 351
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and browser and enter the IP address of the switch in the address field of your web browser. Manage Routing 351 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 352
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and your warranty page displays. For more information, see Register the switch on page 32. Manage Routing 352 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 353
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the default setting. 11. Click the Apply button. Your settings are saved. Manage Routing 353 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 354
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Remove entries from the ARP table You can remove an individual entry, all entries, or selected entries static entry in the Remove IP Address field. 7. Click the Apply button. Manage Routing 354 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 355
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Manage Routing 355 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 356
    7 Configure Quality of Service This chapter covers the following topics: • Quality of Service concepts • Class of Service • Differentiated Services 356
  • Netgear GS752TPPv3 | User Manual - Page 357
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Quality of Service concepts In a switch, each physical port consists of one transmission rate shaping. The switch supports eight queues per port. CoS configuration concepts You can set the Class of Service trust mode for an interface. Each
  • Netgear GS752TPPv3 | User Manual - Page 358
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Alternatively, when a port is configured as untrusted, it does not trust any incoming packet trust mode: • Untrusted: Do not trust any CoS packet marking at ingress. Configure Quality of Service 358 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 359
    1p. • DSCP: The six most significant bits of the DiffServ field are called the Differentiated Services Code Point (DSCP) bits. 7. Click the Apply button. Your settings are saved. Configure > QoS Configuration. The QoS Queue Configuration page displays. Configure Quality of Service 359 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 360
    802.1p. • DSCP: The six most significant bits of the DiffServ field are called the Differentiated Services Code Point (DSCP) bits. 10. In the Interface Shaping Rate field, specify the maximum outbound 12. Click the Save button. Your settings are saved. Configure Quality of Service 360 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 361
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure CoS queue settings for an interface You can define what a particular queue does All). 7. Select one or more interfaces by taking one of the following actions: Configure Quality of Service 361 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 362
    select the type of scheduling that is used for the queue on the interface: • Strict: The interface services traffic with the highest priority on a queue first. • Weighted: The interface uses weighted round robin traffic, such as voice or video. Configure Quality of Service 362 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 363
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 63. Switch default values for 802.1p to queue mapping 802.1p priority 01234567 contains check boxes for each of the eight 802.1p priorities to be mapped. Configure Quality of Service 363 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 364
    Map DSCP values to queues The six most significant bits of the DiffServ field are called the Differentiated Services Code Point (DSCP) bits. The DSCP values go from 1 to 63. You can map each following passwords: • Enter your device admin password. Configure Quality of Service 364 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 365
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Apply button. Your settings are saved. Differentiated Services The QoS feature contains Differentiated Services (DiffServ) support that allows traffic to be classified into
  • Netgear GS752TPPv3 | User Manual - Page 366
    PoE+ Smart Switches with 4 SFP Ports User Manual service can negatively affect applications with strict timing requirements, such as voice and multimedia. Note: For more information about DiffServ and a configuration example, see Differentiated Services (DiffServ) on page 601. Defining DiffServ To
  • Netgear GS752TPPv3 | User Manual - Page 367
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure the DiffServ mode and display the entries in or disable DiffServ: • The toggle is gray and positioned to the left: Differentiated services are disabled. This is the default setting. An existing DiffServ configuration is retained
  • Netgear GS752TPPv3 | User Manual - Page 368
    the policy class instances) out of the total allowed on the switch Service Table The number of configured services (attached to the policies on specific interfaces) out of the total allowed the following passwords: • Enter your device admin password. Configure Quality of Service 368 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 369
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter reference. A class can reference only one other class of the same type. Configure Quality of Service 369 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 370
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Class of Service: Requires the Class of Service (CoS) value in an Ethernet frame header to match the specified CoS value. From the menu below the Class Configuration menu, select a match criterion in
  • Netgear GS752TPPv3 | User Manual - Page 371
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Mask: The bit mask in IP dotted-decimal format indicating from 0 to 63. The DSCP value is defined as the high-order 6 bits of the service type octet in the IP header. • Precedence Value: Requires the packet's IP precedence value to
  • Netgear GS752TPPv3 | User Manual - Page 372
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 12. Click the Apply button. Your settings are saved. The following table The Class Configuration page displays. 6. Click the class name, which is a hyperlink. Configure Quality of Service 372 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 373
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The page on which you can change the class configuration displays. 7. In the DiffServ 7. Click the Edit button. The Edit Class Configuration pop-up window displays. Configure Quality of Service 373 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 374
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Change the name in the Class Name field. The class name can be 1 to 31 . 5. Select QoS > DiffServ > Class Configuration. The Class Configuration page displays. Configure Quality of Service 374 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 375
    Manual 6. Select the check box for the class name. 7. Click the Delete button. Your settings are saved and the class is removed. Configure an IPv6 DiffServ class The switch supports DiffServ functionality for IPv6 by providing support UI on page 31. Configure Quality of Service 375 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 376
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select QoS > DiffServ > IPv6 Class Configuration. field to the right, type a protocol number from 0 to 255. Configure Quality of Service 376 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 377
    DSCP value from 0 to 63. The DSCP value is defined as the high-order 6 bits of the service type octet in the IP header. 11. To add more criteria to the IPv6 DiffServ class, repeat the nonconfigurable information displayed in the Class Summary section. Configure Quality of Service 377 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 378
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 66. IPv6 DiffServ class configuration class summary Field Description Match Criteria The Class Configuration section, change the class configuration as needed. Configure Quality of Service 378 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 379
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For more information about the settings, see Add and configure an IPv6 DiffServ class on page field. The class name can be 1 to 31 alphanumeric characters in length. Configure Quality of Service 379 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 380
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Note: The only option in the Class Type menu is All. You do not need page displays. 6. Select the check box for the class name. 7. Click the Delete button. Configure Quality of Service 380 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 381
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved and the class is removed. Configure a DiffServ policy A DiffServ pop-up window displays. 7. In the Policy Name field, type a policy name. Configure Quality of Service 381 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 382
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The class name can be 1 to 31 alphanumeric characters in length. The name can be value is defined as the high-order 6 bits of the Service Type octet in the IP header. Configure Quality of Service 382 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 383
    , and an action for packets that violate the policy. The switch does not support a color-aware policy. • A simple policy supports a single data rate and results in an action for packets that conforms to the the Apply button. Your settings are saved. Configure Quality of Service 383 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 384
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The following table describes the nonconfigurable fields on the page. Table 67. DiffServ hyperlink. The page on which you can change the policy attributes displays. Configure Quality of Service 384 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 385
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 7. In the Policy Attribute section, change the attributes as needed. For more information Configuration page displays. 6. Select the check box for the policy name. Configure Quality of Service 385 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 386
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If more than one instance of the same policy exists the Login button. The Dashboard page displays. 5. Select QoS > DiffServ > Service Configuration. The Service Configuration page displays. 6. From the Filter By menu, select to display ports
  • Netgear GS752TPPv3 | User Manual - Page 387
    the same settings, select the check box in the heading row. 8. Click the Edit button. The Edit Service Interface Configuration pop-up window displays. 9. From the Policy In Name menu, select the name of a policy in the address field of your web browser. Configure Quality of Service 387 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 388
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the g5) in the Search field and click the Go button. 8. Click the Edit button. The Edit Service Interface Configuration pop-up window displays. 9. From the Policy In Name menu, select None. 10.
  • Netgear GS752TPPv3 | User Manual - Page 389
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display DiffServ service statistics: 1. Connect your computer to the same network as the switch. You can policy instance (with the same policy name) is displayed. Configure Quality of Service 389 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 390
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 69. DiffServ Service Statistics information (Continued) Field Operational Status Description The operational status of the DiffServ policy (Up or Down). The status is displayed as Up if all
  • Netgear GS752TPPv3 | User Manual - Page 391
    servers • TACACS+ servers • Authentication lists • Management access profiles and rules • Port authentication • MAC filters for traffic control • Storm control • Port security • Loop protection • Denial of service 391
  • Netgear GS752TPPv3 | User Manual - Page 392
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change the device admin password This device admin password is the password that you use to log in to time that you log in to the switch, you must use the new password. Manage Switch Security 392 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 393
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you forget the new password, you must reset the switch to factory default settings. Doing so the IP address of the switch in the address field of your web browser. Manage Switch Security 393 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 394
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on- Your settings are saved. The following table describes the nonconfigurable fields on the page. Manage Switch Security 394 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 395
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 70. Radius configuration information Field Current Server IP Address Number of Configured Servers 31. 4. Click the Login button. The Dashboard page displays. Manage Switch Security 395 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 396
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Security > Management Security > RADIUS > Server Configuration. The Server Configuration page displays. 6. settings for an existing RADIUS authentication server. Manage Switch Security 396 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 397
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To change the settings for a RADIUS authentication server: 1. Connect your computer to the same network secondary server. 9. Click the Save button. Your settings are saved. Manage Switch Security 397 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 398
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Remove a RADIUS authentication server from the switch You can remove a RADIUS server with which the switch RADIUS authentication servers that you configure on the switch. Manage Switch Security 398 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 399
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the traffic statistics for the RADIUS authentication servers: 1. Connect your computer to the of RADIUS access-request packets retransmitted to the server Manage Switch Security 399 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 400
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 71. RADIUS authentication server statistics information (Continued) Field Description Access Accepts The number page 29. The Device Admin Password page displays. Manage Switch Security 400 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 401
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. the RADIUS server. 11. Click the Apply button. Your settings are saved. Manage Switch Security 401 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 402
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display the RADIUS accounting server statistics You can display the traffic statistics for the RADIUS . The following table describes the nonconfigurable fields on the page. Manage Switch Security 402 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 403
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 72. RADIUS accounting server statistics information Field Accounting RADIUS and other authentication processes. TACACS+ provides the following services: • Authentication: Provides authentication during login and through user
  • Netgear GS752TPPv3 | User Manual - Page 404
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure the global TACACS+ settings You can configure the global TACACS+ settings for communication between 5 seconds. 8. Click the Apply button. Your settings are saved. Manage Switch Security 404 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 405
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Add a TACACS+ server You can add up to two TACACS+ servers with which the switch can communicate. To A value of 0 is the highest priority. The range is from 0 to 65535. Manage Switch Security 405 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 406
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. In the Port field, type the authentication port number that is used by the TACAS+ server. The value about the credentials, see Credentials for the device UI on page 31. Manage Switch Security 406 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 407
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Security > Management Security > TACACS+. The TACACS+ page see Credentials for the device UI on page 31. Manage Switch Security 407 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 408
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Security > Management Security > TACACS+. The following passwords: • Enter your device admin password. Manage Switch Security 408 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 409
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the method is not tried. 9. Click the Save button. Your settings are saved. Manage Switch Security 409 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 410
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure the HTTPS authentication List You can configure the HTTPS authentication list, which specifies authentication occurs in the order that you select the methods: Manage Switch Security 410 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 411
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Local: The user's locally stored name and password are used for authentication. Because the Local method . For more information, see Register the switch on page 32. Manage Switch Security 411 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 412
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed occurs, you must reset the switch to factory default settings. Manage Switch Security 412 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 413
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Add an access profile You can set up a single security access profile with which you can associate is deactivated. After you add rules, you can activate the access profile. Manage Switch Security 413 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 414
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Add a rule to the access profile After you add the switch from a computer, make sure that you add a permit rule for the type of service that you use (for example, HTTPS), your computer's IP address, and your computer's subnet mask
  • Netgear GS752TPPv3 | User Manual - Page 415
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Add Access Rule Configuration pop-up window displays. criteria. • Deny: Denies access to a device that matches the rule criteria. 8. From the Service Type menu, select the access method or protocol to which the rule applies: TFTP, HTTP,
  • Netgear GS752TPPv3 | User Manual - Page 416
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register to the IP address of the switch in the address field of your web browser. Manage Switch Security 416 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 417
    service type. The source IP address of the client originating the management traffic The subnet mask of the IP address The priority of the rule Change a rule for the access profile You can change an existing security access rule for the access profile. Manage Switch Security 417 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 418
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To change a rule for the access profile: 1. Connect your computer to the same network as the saved. Deactivate the access profile You can deactivate the access profile. Manage Switch Security 418 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 419
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To deactivate the access profile: 1. Connect your computer to the same network as the switch. You can a security access rule that you no longer need for the access profile. Manage Switch Security 419 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 420
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To remove a rule from the access profile: 1. Connect your computer to the same network as the switch. you must deactivate it (see Deactivate the access profile on page 418). Manage Switch Security 420 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 421
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To remove an access profile: 1. Connect your computer to the same network as the switch. You can use to attempt authentication on a port in this mode. Ports in this mode Manage Switch Security 421 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 422
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual are under bidirectional control. 802.1X is the default of the authenticator, and indicates if the supplicant is authorized to access system services. Note: For more information about 802.1X and a configuration example, see
  • Netgear GS752TPPv3 | User Manual - Page 423
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. the left: A VLAN is not dynamically created. This is the default setting. Manage Switch Security 423 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 424
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • The toggle is purple and positioned to the right: A RADIUS-assigned VLAN that does not yet . 3. Enter one of the following passwords: • Enter your device admin password. Manage Switch Security 424 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 425
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the to the network. The supplicants are distinguished by their MAC addresses. Manage Switch Security 425 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 426
    with 4 SFP Ports User Manual 10. If you select . • Enabled: MAB is enabled. If a client device does not support 802.1x, it can still be authenticated. 11. In the Guest VLAN guest VLAN, which allows the port to provide a distinguished service to unauthenticated client devices. Enter an ID in the range
  • Netgear GS752TPPv3 | User Manual - Page 427
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 17. In the Resending EAP field, type the period in seconds for EAP retransmissions. The EAP port access entity (PAE) functionality of the port (Authenticator or Supplicant) Manage Switch Security 427 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 428
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 74. Port authentication information (Continued) Field Authenticator PAE State Backend State Description The . 4. Click the Login button. The Dashboard page displays. Manage Switch Security 428 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 429
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Security > Port Authentication > Port Authentication. The Port Authentication page displays. 6. From the Filter By information, see Register the switch on page 32. Manage Switch Security 429 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 430
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the off-network and not connected to the Internet on page 29. Manage Switch Security 430 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 431
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Device Admin Password page displays. If you did not yet activate your warranty, the Register set to unauthorized. No supplicant can be authorized on the port. Manage Switch Security 431 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 432
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 75. Port summary information (Continued) Field Description Operating Control Mode The control mode under which page 29. The Device Admin Password page displays. Manage Switch Security 432 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 433
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For monitor VLAN. • Not Assigned: The client was not assigned to any VLAN. Manage Switch Security 433 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 434
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 76. Client summary information (Continued) Field Session Timeout Termination Action Description The of the following passwords: • Enter your device admin password. Manage Switch Security 434 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 435
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the Insight Address field. 11. Click the Apply button. Your settings are saved. Manage Switch Security 435 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 436
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Delete a MAC filter You can remove an existing MAC filter that you no longer need. To delete a MAC filter You can display the MAC filters that are configured on the switch. Manage Switch Security 436 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 437
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display the MAC filter summary: 1. Connect your computer to the same network as the switch. You can use a WiFi XX:XX:XX:XX:XX:XX The VLAN ID used with the MAC address Manage Switch Security 437 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 438
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 77. MAC filter summary information (Continued) Field Description Source Port Members The one of the following passwords: • Enter your device admin password. Manage Switch Security 438 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 439
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the the available bandwidth is used by traffic of the configured packet type. Manage Switch Security 439 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 440
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. From the Control Action menu, select which action occurs, if any, if a storm control Dashboard page displays. 5. Select Security > Traffic Control > Storm Control . Manage Switch Security 440 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 441
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Storm Control page displays. The following steps refer to the Port Settings section, in which The port is shut down. 11. Click the Save button. Your settings are saved. Manage Switch Security 441 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 442
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Port security Port security lets you lock one or more ports on the switch. When > Port Security > Port Security Configuration. The Port Security Configuration page displays. Manage Switch Security 442 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 443
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Click the Port Security Mode toggle to enable or disable port security: • The toggle is gray and the IP address of the switch in the address field of your web browser. Manage Switch Security 443 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 444
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and learn dynamically. The range is from 0 to 4096. The default setting is 4096. Manage Switch Security 444 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 445
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. In the Max Static MAC Address field, type the maximum number of statically locked MAC addresses to the Internet on page 29. The Device Admin Password page displays. Manage Switch Security 445 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 446
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. in a numerically ascending order until the static limit is reached. Manage Switch Security 446 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 447
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Display port security violations If you enable port security, you can display port security violations. To display that occurred on ports on which port security is enabled. Manage Switch Security 447 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 448
    violation Loop protection Loops inside a network are costly because they consume resources and reduce the performance of the network. Detecting loops manually can be cumbersome. The switch can automatically identify loops in the network. You can enable loop protection per port or globally. If
  • Netgear GS752TPPv3 | User Manual - Page 449
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Loop protection treats PDU packet transmission and spanning tree protocol in the following ways: • one of the following passwords: • Enter your device admin password. Manage Switch Security 449 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 450
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the (see Configure the global loop protection settings on page 449). Manage Switch Security 450 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 451
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To enable and configure loop protection for an interface and display the loop protection state on The Edit L2 Loop Protection Interface Configuration pop-up window displays. Manage Switch Security 451 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 452
    for classifying and blocking specific types of DoS attacks Configure Auto-DoS You can automatically enable all denial of service (DoS) features that are supported on the switch, except for the TCP port and UDP port DoS features, which you must enable manually. Manage Switch Security 452 User
  • Netgear GS752TPPv3 | User Manual - Page 453
    a warning message. After you have assessed the risk, you can then manually re-enable the port. To configure Auto-DoS: 1. Connect your computer . The Dashboard page displays. 5. Select Security > Denial of Service. The Denial of Service page displays. 6. In the Auto-DoS Configuration section, click
  • Netgear GS752TPPv3 | User Manual - Page 454
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure individual denial of service attack options You can select which types of denial of service (DoS) attacks the switch monitors and blocks. If the switch detects an attack, it shuts down the affected port
  • Netgear GS752TPPv3 | User Manual - Page 455
    with 4 SFP Ports User Manual Enter a value in the range from 0 to 31. The default setting is 20. 7. In the Denial of Service Max ICMP Packet Size field, type the maximum ICMP packet size allowed. If you click the Denial of Service ICMPv4 toggle and Denial of Service ICMPv6 toggle to enable these
  • Netgear GS752TPPv3 | User Manual - Page 456
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Denial of Service TCP Fragment: Enabling TCP Fragment DoS prevention causes the the TCP source port is equal to the TCP destination port. • Denial of Service TCP Source Port: Enabling TCP Source Port DoS prevention causes the switch to drop
  • Netgear GS752TPPv3 | User Manual - Page 457
    9 Configure Access Control Lists This chapter covers the following topics: • About access control lists • ACL Wizard • MAC ACLs • MAC ACL rules • MAC ACL bindings • IPv4 ACLs • Basic IPv4 ACL rules • Extended IPv4 ACL rules • IPv6 ACLs • IPv6 ACL rules • IP ACL bindings • Display the existing ACLs
  • Netgear GS752TPPv3 | User Manual - Page 458
    traffic are forwarded or blocked, and provide security for the network. The switch supports a total of 100 ACLs, which can be a combination of MAC ACLs, Layer 4 port. If you need ACLs with more complex rules, create them manually. Use the ACL Wizard to create a simple ACL The ACL Wizard can help
  • Netgear GS752TPPv3 | User Manual - Page 459
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To use the ACL Wizard to create a simple ACL: 1. Connect your computer to the same network as the an ACL based on the source IPv6 prefix and IPv6 prefix length. Configure Access Control Lists 459 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 460
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • ACL Based on Destination IPv4 L4 Port: Creates an ACL based on the destination IPv4 Layer 4 port the possible match criteria fields, see the following table. Configure Access Control Lists 460 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 461
    source prefix length. Destination IPv4 L4 Port • Destination L4 port (Protocol): Select the destination IPv4 L4 port protocol, or select Other and manually set the destination IPv4 L4 port value. • Destination L4 port (Value): If you select Other, type the destination IPv4 L4 port value. Source
  • Netgear GS752TPPv3 | User Manual - Page 462
    ): Select the destination IPv6 L4 port protocol, or select Other and manually set the destination IPv6 L4 port value. • Destination L4 port (Value port (Protocol): Select the source IPv6 L4 port protocol, or select Other and manually set the source IPv6 L4 port value. • Source L4 port (Value): If
  • Netgear GS752TPPv3 | User Manual - Page 463
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Note: The ACL and associated rule display only while you remain on the page. If you go to to the Internet on page 29. The Device Admin Password page displays. Configure Access Control Lists 463 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 464
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For selection. An ACL is always applied to incoming traffic only. Configure Access Control Lists 464 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 465
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. Click the Apply button. Your settings are saved. Remove an ACL that you created with . 5. Select Security > ACL > ACL Wizard. The ACL Wizard page displays. Configure Access Control Lists 465 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 466
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the ACL Type menu, select the type of ACL. The page adjusts to display the ACLs that you the Internet on page 29. The Device Admin Password page displays. Configure Access Control Lists 466 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 467
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For more a MAC ACL You can change the name of an existing MAC ACL. Configure Access Control Lists 467 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 468
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To change the name of a MAC ACL: 1. Connect your computer to the same network as the switch. , type a new name. 9. Click the Save button. Your settings are saved. Configure Access Control Lists 468 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 469
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Remove a MAC ACL You can remove a MAC ACL that you no longer need. To remove a MAC ACL: 1. the Delete button. Your settings are saved and the MAC ACL is removed. Configure Access Control Lists 469 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 470
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual MAC ACL rules You can define rules for MAC-based ACLs. The access list definition includes rules ACL > MAC ACL > MAC ACL/Rule. The MAC ACL/Rule Table page displays. Configure Access Control Lists 470 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 471
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The MAC ACL section displays the total number of MAC ACLs, IPv4 ACLs, and IPv6 ACLs that are need to match the ACL rule. • True: Each packet must match the ACL rule. Configure Access Control Lists 471 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 472
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 15. In the CoS field, type the 802.1p priority that must be compared against the information in an Ethernet in an Ethernet frame. The format is xx:xx:xx:xx:xx:xx. Configure Access Control Lists 472 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 473
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 22. In the VLAN field, type the VLAN ID that must be compared against the information in Enter one of the following passwords: • Enter your device admin password. Configure Access Control Lists 473 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 474
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • If you previously managed the switch through the Insight Cloud Portal or Insight app, enter the address of the switch in the address field of your web browser. Configure Access Control Lists 474 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 475
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network and rules that are defined for the ACL are applied to the selected interface. Configure Access Control Lists 475 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 476
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure a MAC ACL interface binding You can bind an MAC ACL to one or more interfaces, which can be If you do not set the sequence number, a sequence number that Configure Access Control Lists 476 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 477
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual is one number greater than the highest sequence number currently in use for the interface is used. > ACL > MAC ACL > Binding Table. The Binding Table page displays. Configure Access Control Lists 477 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 478
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. To delete a MAC ACL-to-interface binding, do the a match. You must associate the IPv4 ACL with one or more interfaces. The switch supports basic and extended IPv4 ACLs: • Basic IPv4 ACL: Lets the switch permit or deny traffic
  • Netgear GS752TPPv3 | User Manual - Page 479
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Multiple steps are involved in defining an IPv4 ACL and applying it to the switch: 1. Add an the Insight network password for the last Insight network location. Configure Access Control Lists 479 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 480
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device UI on page 31. 4. Click the Login button. procedure applies to basic and extended IPv4 ACLs. Configure Access Control Lists 480 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 481
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To change the number or name of an IPv4 ACL: 1. Connect your computer to the same network as length. The name must start with a letter. 9. Click the Save button. Configure Access Control Lists 481 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 482
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved. Remove an IPv4 ACL You can remove a basic or extended IPv4 ACL that you Delete button. Your settings are saved and the IP ACL is removed. Configure Access Control Lists 482 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 483
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Basic IPv4 ACL rules You can define rules for basic IPv4-based ACLs. The access list The Dashboard page displays. 5. Select Security > ACL > IP ACL > IP ACL/Rules. Configure Access Control Lists 483 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 484
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The IP ACL/Rules page displays. The IP ACL Configuration section displays the total number of IPv4 ACLs, for the rule. You do not need to configure all criteria. Configure Access Control Lists 484 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 485
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 13. (Optional) If you select the Permit Action radio button, select a hardware egress queue ID from the , click the Save button. The rule is added to the IP ACL. Configure Access Control Lists 485 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 486
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Each ACL displays the following information: - Rules: The number of rules for the IP ACL. - Type: The > ACL > IP ACL > IP ACL/Rules. The IP ACL/Rules page displays. Configure Access Control Lists 486 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 487
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The IP ACL Configuration section displays the total number of IPv4 ACLs, IPv6 ACLs, and MAC ACLs displays. For more information, see Register the switch on page 32. Configure Access Control Lists 487 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 488
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously as one task. The following procedure describes both options. Configure Access Control Lists 488 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 489
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add a rule for an existing or new extended IPv4 ACL: 1. Connect your computer to the closes, and the Extended ACL Rule Configuration (100-199) section displays. Configure Access Control Lists 489 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 490
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. Do one of the following: • Add a rule to an existing extended IP ACL: From the ACL ID/Name for this ACL rule (subject to resource availability on the switch). Configure Access Control Lists 490 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 491
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 15. (Optionally) If you select the Permit Action radio button, select an Interface radio button to to set an individual port number or a range of port numbers: Configure Access Control Lists 491 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 492
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You can select the Port radio button or the Range radio button: • Port: Select one of the select to set an individual port number or a range of port numbers: Configure Access Control Lists 492 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 493
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You can select the Port radio button or the Range radio button: • Port: Select one of the following radio button, from the menu, select the type of the ICMP message: Configure Access Control Lists 493 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 494
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual echo, echo-reply, host-redirect, mobile-redirect, net-redirect Code Point (DSCP) field in a packet is defined as the high-order 6 bits of the service type octet in the IP header. Select a keyword from the IP DSCP menu. If you select
  • Netgear GS752TPPv3 | User Manual - Page 495
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 26. Click one of the following buttons: • Save: To save your settings, click the Save button. The page 31. 4. Click the Login button. The Dashboard page displays. Configure Access Control Lists 495 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 496
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Security > ACL > IP ACL > IP ACL/Rules. The IP ACL/Rules page displays. The IP ACL the Internet on page 29. The Device Admin Password page displays. Configure Access Control Lists 496 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 497
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For . You must associate the IPv6 ACL with one or more interfaces. Configure Access Control Lists 497 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 498
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Multiple steps are involved in defining an IPv6 ACL and applying it to the switch: 1. Add an Credentials for the device UI on page 31. 4. Click the Login button. Configure Access Control Lists 498 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 499
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Dashboard page displays. 5. Select Security > ACL > IP ACL > IPv6 ACL/Rules. The IPv6 ACL/Rules page . For more information, see Register the switch on page 32. Configure Access Control Lists 499 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 500
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed For more information, see Register the switch on page 32. Configure Access Control Lists 500 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 501
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously , as one task. The following procedure describes both options. Configure Access Control Lists 501 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 502
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To add a rule for an existing or new IPv6 ACL: 1. Connect your computer to the same network The window closes, and the IPv6 ACL Rule Configuration section displays. Configure Access Control Lists 502 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 503
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. Do one of the following: • Add a rule to an existing IPv6 ACL: From the ACL ID/Name menu, select this ACL rule (subject to resource availability on the switch). Configure Access Control Lists 503 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 504
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 14. (Optionally) If you select the Permit Action radio button, select an Interface radio button to to set an individual port number or a range of port numbers: Configure Access Control Lists 504 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 505
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You can select the Port radio button or the Range radio button: • Port: Select one of the select to set an individual port number or a range of port numbers: Configure Access Control Lists 505 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 506
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You can select the Port radio button or the Range radio button: • Port: Select one of the following are specified. That is, the ICMPv6 message is decoded into the Configure Access Control Lists 506 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 507
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual corresponding ICMPv6 type and ICMPv6 code within the ICMPv6 type The IPv6 DSCP field in a packet is defined as the high-order 6 bits of the service type octet in the IPv6 header. The IPv6 DSCP is compared to packet's IPv6 DSCP field.
  • Netgear GS752TPPv3 | User Manual - Page 508
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Change the match criteria for an IPv6 ACL rule You can change the match criteria for an . The page adjusts and displays the IPv6 ACL Rule Configuration section. Configure Access Control Lists 508 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 509
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. Change the settings as needed. For more information about the settings, see Add a rule for an > ACL > IP ACL > IPv6 ACL/Rules. The IPv6 ACL/Rules page displays. Configure Access Control Lists 509 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 510
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The IPv6 ACL Configuration section displays the total number of IPv6 ACLs, IPv4 ACLs, and MAC ACLs the Internet on page 29. The Device Admin Password page displays. Configure Access Control Lists 510 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 511
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. For delete bindings for basic IPv4, extended IPv4, and IPv6 ACLs. Configure Access Control Lists 511 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 512
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display IP ACL bindings or delete an IP ACL binding: 1. Connect your computer to the same network the information that is displayed in the IP ACL Binding Table. Configure Access Control Lists 512 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 513
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 82. Interface IP ACL binding status information Field Description Interface The interface to which , see Credentials for the device UI on page 31. Configure Access Control Lists 513 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 514
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Make one of the following selections, depending on the type on page 480 Remove an IPv4 ACL on page 482 Configure Access Control Lists 514 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 515
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 83. Sections that provide information about changing or removing an ACL or rule (Continued) Section For more information, see Register the switch on page 32. Configure Access Control Lists 515 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 516
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed VLAN ACL bindings in the VLAN Binding Configuration table. Configure Access Control Lists 516 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 517
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display VLAN ACL bindings or delete a VLAN ACL binding: 1. Connect your computer to the same that is displayed in the VLAN Binding Configuration table. Configure Access Control Lists 517 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 518
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 84. Interface MAC ACL binding information Field Description VLAN ID The ID of the VLAN to which the Type The type of ACL ACL ID The ACL number or name Configure Access Control Lists 518 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 519
    10 Maintenance and Troubleshooting This chapter covers the following topics: • Reboot the switch from the device UI • Reset the switch to factory switch to another device • Update the swich software • Download a file to the switch • Manage software images • Diagnostics and troubleshooting 519
  • Netgear GS752TPPv3 | User Manual - Page 520
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Reboot the switch from the device UI You can reboot the switch from the device window displays. The switch reboots. 7. Click the OK button to close the window. Maintenance and 520 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 521
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Reset the switch to factory default settings You can reset the switch configuration to but keep the registered device status: Click the Factory Reset button. Maintenance and 521 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 522
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Reset and erase everything, including registered device status: Click the Erase button. A credentials, see Credentials for the device UI on page 31. Maintenance and 522 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 523
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. Support: The tech support file is a text-based file that contains a variety of hardware, software, and configuration information that can assist in device and network troubleshooting
  • Netgear GS752TPPv3 | User Manual - Page 524
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • The toggle is purple and positioned to the right: The file transfer is enabled. The file From the File Type menu, select the type of file that must be exported: Maintenance and 524 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 525
    PoE+ Smart Switches with 4 SFP Ports User Manual • Text Configuration: A text-based configuration file enables Support: The tech support file is a text-based file that contains a variety of hardware, software, and configuration information that can assist in device and network troubleshooting
  • Netgear GS752TPPv3 | User Manual - Page 526
    download the firmware to the switch. If firmware release notes are available with new firmware, read the release notes to find out if you must reconfigure the switch after updating. In this context, downloading is also referred to as upgrading. Maintenance and 526 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 527
    Firmware/File Update page displays. 6. From the File Type menu, select Software. This selection represents the switch software image, which is saved in one of two flash sectors called images (Image1 and Image2). The active image stores the active Maintenance and 527 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 528
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual copy, while the other image stores a second copy. The device boots and runs from refreshes. The page displays information about the progress of the file transfer. Maintenance and 528 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 529
    verify that the switch runs the newly activated image. On the Dashboard page, the Firmware Version field displays the firmware image that the switch runs. Download the switch software from a computer and update , see Register the switch on page 32. Maintenance and 529 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 530
    the Login button. The Dashboard page displays. 5. Select Maintenance > Update > HTTP Firmware/File Update. The HTTP Firmware/File Update page displays. 6. From the File Type menu, select Software. This selection the progress of the file transfer. Maintenance and 530 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 531
    that the switch runs the newly activated image. On the Dashboard page, the Firmware Version field displays the firmware image that the switch runs. Download the switch software from a USB storage device . The Device Admin Password page displays. Maintenance and 531 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 532
    the Login button. The Dashboard page displays. 6. Select Maintenance > Update > USB Firmware/File Update. The USB Firmware/File Update page displays. 7. From the File Type menu, select Software. This selection the progress of the file transfer. Maintenance and 532 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 533
    switch, HTTPS must be administratively disabled. Download a file from a TFTP server to the switch You can download a software (firmware) image and configuration, SSL, PEM, or other types of files from a TFTP server on your network to the switch. Maintenance and 533 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 534
    Click the Login button. The Dashboard page displays. 5. Select Maintenance > Update > TFTP Firmware/File Update. The TFTP Firmware/File Update page displays. 6. From the File Type menu, select the type of file: and update the switch on page 527. Maintenance and 534 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 535
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Text Configuration: A text-based configuration file enables you to edit a configured text configuration file, the switch applies the configuration automatically. Maintenance and 535 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 536
    the Login button. The Dashboard page displays. 5. Select Maintenance > Update > HTTP Firmware/File Update. The HTTP Firmware/File Update page displays. 6. From the File Type menu, select the type of startup-config) offline as needed. The most common Maintenance and 536 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 537
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual usage of text-based configuration is to upload a working configuration from a device, edit it IP address of the switch in the address field of your web browser. Maintenance and 537 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 538
    button. The Dashboard page displays. 6. Select Maintenance > Update > USB Firmware/File Update. The USB Firmware/File Update page displays. 7. From the File Type menu, select Text Configuration the switch applies the configuration automatically. Maintenance and 538 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 539
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Download and install an SSL security certificate file on the switch If you use HTTPS about the credentials, see Credentials for the device UI on page 31. Maintenance and 539 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 540
    your browser, and log back in to the switch. 9. Select Maintenance > Update > HTTP Firmware/File Update. The HTTP Firmware/File Update page displays. 10. From the File Type menu, select X.509 Public Certificate the progress of the file transfer. Maintenance and 540 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 541
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Manage software images The switch maintains two versions of the switch software in displays. 5. Select Maintenance > File Management. The File Management page displays. Maintenance and 541 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 542
    that the switch runs the newly activated image. On the Dashboard page, the Firmware Version field displays the firmware image that the switch runs. Display the dual image configuration and add image connected to the Internet on page 29. Maintenance and 542 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 543
    The name of the image. By default, the image names are image1 and image2. The firmware version of the image. Copy a software image from one flash sector to another You can copy a software image from one flash sector (primary or backup) to another. Maintenance and 543 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 544
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To copy a software image from one flash sector to another: 1. Connect your computer to a software image You can delete a software image that you no longer need. Maintenance and 544 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 545
    that is not the active image. Your settings are saved and the image is removed. Diagnostics and troubleshooting You can send a ping, trace a route, and perform a memory dump. Ping an IPv4 address switch can communicate with a particular IPv4 Maintenance and 545 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 546
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual device. When you send a ping, the switch sends a specified number of ping requests and the UI on page 31. 4. Click the Login button. The Dashboard page displays. Maintenance and 546 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 547
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Maintenance > Troubleshooting > Ping IPv4. The Ping IPv4 page displays. 6. In the IP Address specified number of ping requests and the results are displayed. Maintenance and 547 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 548
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If a reply to the ping is received, the following message displays: PING button. The Dashboard page displays. 5. Select Maintenance > Troubleshooting > Ping IPv6. The Ping IPv6 page displays. Maintenance and 548
  • Netgear GS752TPPv3 | User Manual - Page 549
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. From the Ping menu, select the type of ping: • Global: Pings a global IPv6 address. • traceroute, the switch displays the results below the configurable data. Maintenance and 549 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 550
    page 31. 4. Click the Login button. The Dashboard page displays. 5. Select Maintenance > Troubleshooting > Traceroute IPv4. The Traceroute IPv4 page displays. 6. In the IP Address/Hostname field, type maximum time to live (TTL) for the destination. Maintenance and 550 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 551
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The default setting is 30. The range is from 1 to 255. 9. In the Init TTL When you send a traceroute, the switch displays the results below the configurable data. Maintenance and 551 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 552
    on page 31. 4. Click the Login button. The Dashboard page displays. 5. Select Maintenance > Troubleshooting > Traceroute IPv6. The Traceroute IPv6 page displays. 6. In the IPv6 Address/Host Name field, maximum time to live (TTL) for the destination. Maintenance and 552 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 553
    field. Enable the secure diagnostic mode Secure diagnostics mode connects the switch to NETGEAR's diagnostic server, allowing support personnel to remotely diagnose your system. In this mode, changes to the default configuration are not saved. Maintenance and 553 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 554
    page 31. 4. Click the Login button. The Dashboard page displays. 5. Select Maintenance > Troubleshooting > Secure Diagnostics. The Secure Diagnostics page displays. 6. Click the Secure Diagnostic Mode toggle port that is connected to the server. Maintenance and 554 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 555
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual You cannot log in to the switch After you enter the wrong password three times • After 12 times: 40 minutes • After 15 times: 60 minutes • After 18 times: 60 minutes Maintenance and 555 Troubleshooting User Manual
  • Netgear GS752TPPv3 | User Manual - Page 556
    11 Monitor the Switch and Network This chapter covers the following topics: • Switch, port, and EAP packet statistics • Perform a cable test • Logs • Port mirroring • Switch CPU 556
  • Netgear GS752TPPv3 | User Manual - Page 557
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Switch, port, and EAP packet statistics You can view switch and port statistics, including detailed statistics, switch statistics that are displayed on the page. Monitor the Switch and Network 557 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 558
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 86. Switch statistics information Field Description Unicast Packets Unicast Packets Received The number a packet could be to free up buffer space. Monitor the Switch and Network 558 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 559
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 86. Switch statistics information (Continued) Field Description Transmit Packets Discarded The number of outbound , see Register the switch on page 32. Monitor the Switch and Network 559 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 560
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you previously managed the that were transmitted by this port to its segment Monitor the Switch and Network 560 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 561
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 87. Port statistics information (Continued) Field Transmit Packet Errors Collision Frames Link . 5. Select Monitoring > Ports > Port Detailed Statistics. Monitor the Switch and Network 561 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 562
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Port Detailed Statistics page displays. 6. From the Interface menu, select the interface (a Disabled • Blocking • Listening • Learning • Forwarding • Broken Monitor the Switch and Network 562 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 563
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 88. Port detailed statistics information (Continued) Field Description Admin Mode The port control (excluding framing bits but including FCS octets) Monitor the Switch and Network 563 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 564
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 88. Port detailed statistics information (Continued) Field Description Packets Received 128-255 Octets excluding framing bits but including FCS octets) Monitor the Switch and Network 564 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 565
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 88. Port detailed statistics information (Continued) Field at 10 Mb/s. Maximum Frame Size The maximum Ethernet frame size that the interface supports or is configured to use, including the Ethernet header, CRC, and payload. The
  • Netgear GS752TPPv3 | User Manual - Page 566
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 88. Port detailed statistics information (Continued) Field Description Total Packets Transmitted Successfully interface is operating in half-duplex mode. Monitor the Switch and Network 566 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 567
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 88. Port detailed statistics information (Continued) Field Description GVRP PDUs Received The number of see Credentials for the device UI on page 31. Monitor the Switch and Network 567 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 568
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Monitoring > Ports > EAP Statistics. The EAP Statistics that were received by the authenticator Monitor the Switch and Network 568 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 569
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 89. EAP statistics information (Continued) Field Description Response Frames Received The number page displays. 5. Select Monitoring > Ports > Cable Test. Monitor the Switch and Network 569 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 570
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Cable Test page displays. 6. Select the check boxes cable status is always Normal. The command returns a cable length estimate if this feature is supported by the PHY for the current link speed. Note that if the link is down and
  • Netgear GS752TPPv3 | User Manual - Page 571
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual purposes or long-term archival storage (see Syslog and log server host settings on page 576). Local and of the switch in the address field of your web browser. Monitor the Switch and Network 571 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 572
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch on-network , Critical, Alert, and Emergency. The default severity level is Informational (6). Monitor the Switch and Network 572 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 573
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The severity can be one of the following levels: , persistent log, or console log. Messages logged to a collector or relay through syslog support the same format as well. The following example shows the standard format for a log message
  • Netgear GS752TPPv3 | User Manual - Page 574
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. To clear the log, click the Clear button. Manage and display the flash log The flash log is a logging messages to flash memory. This is the default setting. Monitor the Switch and Network 574 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 575
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • The toggle is purple and positioned to the right: Flash logging is enabled, which enables the switch shows the standard format for a persistent log message: Monitor the Switch and Network 575 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 576
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Jan 12 2023 00:00:18: AAA-5-CONNECT: New http connection for user admin, source 192.168.1. enter the Insight network password for the last Insight network location. Monitor the Switch and Network 576 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 577
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For information about the credentials, see Credentials for the device UI on page 31. 4. Click the Login button Click the Login button. The Dashboard page displays. Monitor the Switch and Network 577 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 578
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Monitoring > Logs > Server Log. The Server Log page displays. 6. Click the Add New button. The Add can change the settings to an existing syslog server. Monitor the Switch and Network 578 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 579
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To change the settings for a syslog server: 1. Connect your computer to the same network as the switch. the settings for a syslog server that you no longer need. Monitor the Switch and Network 579 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 580
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To delete the settings for a syslog server: 1. Connect your computer to the same network as the switch. You and clear the counters and entries in the trap log. Monitor the Switch and Network 580 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 581
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To display or clear the trap log: 1. Connect your computer to the same network as the switch. exceeds the capacity, the new entries overwrite the oldest entries. Monitor the Switch and Network 581 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 582
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 91. Trap log information (Continued) Field Description Number of Traps since log The number of traps on page 29. The Device Admin Password page displays. Monitor the Switch and Network 582 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 583
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you did not yet activate your warranty, the Register to activate your warranty page displays. . The Edit Source Interface Configuration pop-up window displays. Monitor the Switch and Network 583 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 584
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 12. From the Direction menu, select the direction of the traffic that must be mirrored: • None: The Dashboard page displays. 5. Select Monitoring > Port Mirroring. Monitor the Switch and Network 584 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 585
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The Mirroring page displays. 6. From the Destination Port menu, select None. 7. Click the Apply button. . 4. Click the Login button. The Dashboard page displays. Monitor the Switch and Network 585 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 586
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Select Monitoring > System CPU Status > System CPU Status. The System CPU Status page displays. 6. To refresh the , see Credentials for the device UI on page 31. Monitor the Switch and Network 586 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 587
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 4. Click the Login button. The Dashboard page displays. 5. Select Monitoring > System CPU Status > CPU Threshold. Click the Apply button. Your settings are saved. Monitor the Switch and Network 587 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 588
    This appendix contains information about how to configure the following features: • Virtual Local Area Networks (VLANs) • Access control lists (ACLs) • Differentiated Services (DiffServ) • 802.1X port access control • Multiple Spanning Tree Protocol • VLAN routing interface example configuration 588
  • Netgear GS752TPPv3 | User Manual - Page 589
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Virtual Local Area Networks (VLANs) A local area network ( it is automatically tagged with the port's default VLAN ID tag number. Each port supports a default VLAN ID setting that is configurable (the default setting is 1). For
  • Netgear GS752TPPv3 | User Manual - Page 590
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • When a tagged packet enters a port, the tag for that packet is unaffected by the default VLAN ID page displays. For more information, see Register the switch on page 32. Configuration Examples 590 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 591
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 3. Enter one of the following passwords: • Enter your device admin password. • If you > VLAN > VLAN Configuration (Basic). The VLAN Configuration (Basic) page displays. Configuration Examples 591 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 592
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 8. Configure the membership for each VLAN: • For the default VLAN with VLAN ID 1, > VLAN > VLAN Configuration (Advanced). The VLAN Configuration (Advanced) page displays. Configuration Examples 592 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 593
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 10. Set the PVID for port g1 to VLAN ID 10 and the PVID for port g4 can access specific resources while blocking off any unwarranted attempts to reach network resources. Configuration Examples 593 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 594
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual ACLs are used to provide traffic flow control, restrict direction. The switch allow ACLs to be bound to physical ports and LAGs. The switch supports MAC ACLs, IPv4 ACLs, and IPv6 ACLs. MAC ACL example configuration The following example shows
  • Netgear GS752TPPv3 | User Manual - Page 595
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Source MAC Mask: 00:00:00:00:FF:FF • VLAN ID: 2, which is the VLAN that is used for inbound direction, which means that the switch examines traffic as it enters the port. Configuration Examples 595 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 596
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual For more information about adding an IPv4 ACL, see Add a MAC ACL on page 466. 7. of 1: a. From the ACL ID menu, select Sales_ACL. b. In the Sequence Number field, type 1 Configuration Examples 596 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 597
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual This number defines the order of the MAC ACL relative to other ACLs that are bound to the : • Sequence Number: 1 • Action: Deny • Assign Queue ID: 4 • Match Every: No Configuration Examples 597 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 598
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • EtherType: IPv4 • Source IP address: 192.168.187.0 • Source IP Mask: 255.255.0.0 3. Create a Dashboard page displays. 5. Select Security > ACL > IP ACL > IP ACL/Rules. Configuration Examples 598 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 599
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual The IP ACL/Rules page displays. 6. Add a basic IP ACL: a. Click the Add New button. The Add must be compared against the packet's source IP mask. g. Click the Save button. Configuration Examples 599 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 600
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your settings are saved and the rule is added. 12. Click the Add New button. and 4. The selected ports display blue. d. Click the Apply button. Your settings are saved. Configuration Examples 600 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 601
    User Manual Services (DiffServ) Standard IP-based networks are designed to provide best effort data delivery service. Best effort service service is acceptable and in many cases unnoticeable. However, any degradation of service of Service ( QoS: • Integrated Services: Network resources are Services:
  • Netgear GS752TPPv3 | User Manual - Page 602
    User Manual The DiffServ feature contains a number of conceptual QoS building blocks that you can use to construct a differentiated service /inner VLAN tag) • Secondary VLAN ID range (second/inner VLAN tag) • IP Service Type octet (also known as: ToS bits, Precedence value, DSCP value) • Layer
  • Netgear GS752TPPv3 | User Manual - Page 603
    perspective, there are two types of policies: • Traffic conditioning policy: A policy applied to a DiffServ traffic class • Service provisioning policy: A policy applied to a DiffServ service level You must manually configure the various statements and rules used in the traffic conditioning and
  • Netgear GS752TPPv3 | User Manual - Page 604
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual • Policing: A method of constraining incoming traffic associated with QoS queue. This allows a traffic classifier to specify which one of the supported hardware queues is used for handling packets belonging to the class. •
  • Netgear GS752TPPv3 | User Manual - Page 605
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual In this example, you do the following: 1. Add a class with the following five criteria: Select QoS > DiffServ > Class Configuration. The Class Configuration page displays. Configuration Examples 605 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 606
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 6. Add the DiffServ class: a. Click the Add New button. The Add Class Configuration pop-up window displays. the second set of criteria is added to the Class Summary section. Configuration Examples 606 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 607
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 9. For class 1, configure the third set of criteria, which is for the source port: a. On QoS > DiffServ > Policy Configuration. The Policy Configuration page displays. Configuration Examples 607 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 608
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 13. Add the policy: a. Click the Add New button Select the check boxes for interfaces 7 and 8. b. Click the Edit button. The Edit Service Interface Configuration pop-up window displays. c. From the Policy In Name menu, select Policy1,
  • Netgear GS752TPPv3 | User Manual - Page 609
    4 SFP Ports User Manual 802.1X port access configure a port to enable or disable EAPoL packet forwarding support. You can disable or enable the forwarding of EAPoL when authenticator switch provide the means by which it can offer services to other systems reachable through the LAN. Port-based
  • Netgear GS752TPPv3 | User Manual - Page 610
    Manual A Port Access Entity (PAE) is able to adopt one of two distinct roles within an access control interaction: 1. Authenticator: A port that enforces authentication before allowing access to services authentication server are required. The switch supports the authenticator role only, in which
  • Netgear GS752TPPv3 | User Manual - Page 611
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual If you do not know the IP address of the switch, see Access the switch Security > Port Authentication > 802.1x Configuration. The 802.1x Configuration page displays. Configuration Examples 611 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 612
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 12. Click the Port-Based Authentication State toggle to enable 802.1X port-based authentication. Edit button. The Edit Dot1x Authentication List pop-up window displays. Configuration Examples 612 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 613
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 21. To enable the Dot1x list, select the dotxList check box an RSTP bridge or an STP bridge. So, an IEEE 802.1s bridge inherently also supports IEEE 802.1w and IEEE 802.1D. The MSTP algorithm and protocol provide simple and full
  • Netgear GS752TPPv3 | User Manual - Page 614
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual MSTP connects all bridges and LANs with a single Common and Internal Spanning Tree (CIST). The CIST supports the automatic determination of each MST region, choosing its maximum possible extent. The connectivity
  • Netgear GS752TPPv3 | User Manual - Page 615
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To support multiple spanning trees, configure an MSTP bridge with an • The allocation of VIDs to FIDs is unambiguous. • Each FID that is supported by the bridge is allocated to exactly one spanning tree instance. The combination of
  • Netgear GS752TPPv3 | User Manual - Page 616
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 5. Enable STP on ports 1 through 8. 6. Create MST instance 1 that is associated with VLAN 300 7. Create the new VLAN or leave the field blank. d. Click the Save button. Configuration Examples 616 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 617
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Your setting are saved and the VLAN is added. • Create a VLAN with VLAN ID 500: a. Click . Your settings are saved. 9. Select Switching > STP > STP. The STP page displays. Configuration Examples 617 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 618
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Configure the following global settings: a. If the Spanning Tree State toggle is gray and positioned to on page 212. d. Click the Save button. Your settings are saved. Configuration Examples 618 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 619
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual e. Select the check boxes for ports g1 through g5. f. Click the Edit button. The Edit CST Port Click the Save button. Your settings are saved and the MST is added. Configuration Examples 619 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 620
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual In this example, Switch 1 (with bridge priority 4096) became 12288) became the root bridge for MST instance 2 (with priority 49152). Each switch supports devices in their sales department (ports g1, g2, and g3) and in their HR
  • Netgear GS752TPPv3 | User Manual - Page 621
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual To configure the VLAN routing interface example: 1. Connect your computer to the same network as the switch 192.168.200.20 as the address for the VLAN routing interface. Configuration Examples 621 User Manual
  • Netgear GS752TPPv3 | User Manual - Page 622
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual 11. In the Network Mask field, type 255.255.255.0 Port button. 14. Click the Apply button. Your settings are saved. The switch supports routing on ports g19 and g20, both of which are untagged members of the routing VLAN with
  • Netgear GS752TPPv3 | User Manual - Page 623
    • ACL features default settings • Monitoring features default settings • Models GS728TPv3 and GS728TPPv3 hardware technical specifications • Models GS752TPv3 and GS752TPPv3 hardware technical specifications Note: For more information about the switch specifications and capabilities, including the
  • Netgear GS752TPPv3 | User Manual - Page 624
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Access default settings for the switch device UI The following included in the data sheet, which you can download by visiting netgear.com/support/download/. Table 93. Default settings for access to the switch device UI Feature
  • Netgear GS752TPPv3 | User Manual - Page 625
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 94. System features default settings Feature Name/Setting Time Configuration Clock 1 4 Disabled Enabled None configured Enabled Disabled Disabled Software Default Settings and 625 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 626
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 94. System features default settings (Continued) Feature Name/Setting TLV advertised interval None Enabled 5 24 4 Disabled 443 5 Software Default Settings and 626 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 627
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 94. System features default settings (Continued) Feature in the data sheet, which you can download by visiting netgear.com/support/download/. VLAN features default settings The following table describes the default settings
  • Netgear GS752TPPv3 | User Manual - Page 628
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 95. VLAN features default settings (Continued) Feature Name/Setting VLAN tag Acceptable frame :1B:4F AVAYA2 Traffic Class 7 Disabled Software Default Settings and 628 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 629
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 95. VLAN features default settings (Continued) Feature in the data sheet, which you can download by visiting netgear.com/support/download/. Switching features default settings The following table describes the default settings
  • Netgear GS752TPPv3 | User Manual - Page 630
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 96. Switching features default settings (Continued) Feature Name/Setting Notification MED capabilities Disabled 1522 Enabled Enabled Software Default Settings and 630 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 631
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 96. Switching features default settings (Continued) Feature Name/Setting Speed Duplex mode Link address 0 Disabled 32768 20 2 15 20 Software Default Settings and 631 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 632
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 96. Switching features default settings (Continued) Feature Name/Setting CST Port None configured Disabled Enabled Disabled Disabled Disabled Software Default Settings and 632 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 633
    -Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 96. Switching features default settings (Continued) Feature Name/Setting Rate limit Burst Disabled Enabled Disabled Disabled 15 1 Software Default Settings and 633 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 634
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 96. Switching features default settings (Continued) Feature in the data sheet, which you can download by visiting netgear.com/support/download/. Multicast features default settings The following table describes the default settings
  • Netgear GS752TPPv3 | User Manual - Page 635
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 97. Multicast features default settings (Continued) Feature Name/Setting Default Query mode Disabled Query interval 60 Multicast Router Interface Configuration Multicast router Disabled Multicast
  • Netgear GS752TPPv3 | User Manual - Page 636
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 97. Multicast features default settings (Continued) Feature Name/Setting Default , which you can download by visiting netgear.com/support/download/. Software Default Settings and 636 Hardware Specifications User
  • Netgear GS752TPPv3 | User Manual - Page 637
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Routing features default settings The following table describes the default settings for the routing 600 Disabled Disabled Medium Disabled Enabled Software Default Settings and 637 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 638
    48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 98. Routing features default settings (Continued) Feature Name/Setting Default , which you can download by visiting netgear.com/support/download/. Software Default Settings and 638 Hardware Specifications User
  • Netgear GS752TPPv3 | User Manual - Page 639
    PoE+ Smart Switches with 4 SFP Ports User Manual QoS features default settings The following table describes the 4 -> 2 5 -> 2 6 -> 3 7 -> 3 CS 0 -> 1 CS 1 -> 0 CS 2 -> 0 CS 3 -> 1 CS 4 -> 2 CS 5 -> 2 CS 6 -> 3 CS 7 -> 3 Software Default Settings and 639 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 640
    Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 99. QoS features default settings (Continued) Feature Name/Setting 2 35 -> 2 37 -> 2 39 -> 2 41 -> 2 42 -> 2 43 -> 2 44 -> 2 45 -> 2 47 -> 2 49 -> 3 Software Default Settings and 640 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 641
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 99. QoS features default settings (Continued) Feature Service None configured Nonconfigurable settings are not included in the table but might be included in the data sheet, which you can download by visiting netgear.com/support
  • Netgear GS752TPPv3 | User Manual - Page 642
    and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 100. Security features default settings Feature Name/Setting User Configuration Password 2 through 4 are not configured Disabled Blank Software Default Settings and 642 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 643
    Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 100. Security features default settings (Continued) Feature Name/Setting Access profile 2 30 30 None configured Disabled Disabled 5 Software Default Settings and 643 Hardware Specifications User Manual
  • Netgear GS752TPPv3 | User Manual - Page 644
    -Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 100. Security features default settings (Continued) Feature Name/Setting DoS mode Disabled Denial of Service Configuration Denial of Service minimum TCP header size Blank Denial of Service maximum ICMPv4 packet size
  • Netgear GS752TPPv3 | User Manual - Page 645
    Switches with 4 SFP Ports User Manual Table 100. Security features default settings (Continued) Feature Name/Setting Default Denial of Service ICMPv4 Disabled Denial of Service ICMPv6 Disabled Denial of Service Ping of Death Disabled Denial of Service IPv6 fragment Disabled Denial of
  • Netgear GS752TPPv3 | User Manual - Page 646
    24-Port and 48-Port Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 101. ACL features default settings Feature Name/Setting Default Total number of supported ACLs 100. This total number applies to all MAC ACLs, IP basic ACLs, IP extended ACLs, and IPv6 ACLs together.
  • Netgear GS752TPPv3 | User Manual - Page 647
    Gigabit Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 102. Monitoring features default settings (Continued) Feature data sheet, which you can download by visiting netgear.com/support/download/. Models GS728TPv3 and GS728TPPv3 hardware technical specifications The following
  • Netgear GS752TPPv3 | User Manual - Page 648
    Ethernet PoE+ Smart Switches with 4 SFP Ports User Manual Table 103. Hardware technical specifications for models GS728TPv3 and GS728TPPv3 which you can download by visiting netgear.com/support/download/. Models GS752TPv3 and GS752TPPv3 hardware technical specifications The following table
  • Netgear GS752TPPv3 | User Manual - Page 649
    + Smart Switches with 4 SFP Ports User Manual Table 104. Hardware technical specifications for models GS752TPv3 and GS752TPPv3 (Continued) Feature Description Both Models you can download by visiting netgear.com/support/download/. Software Default Settings and 649 Hardware Specifications User
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384
  • 385
  • 386
  • 387
  • 388
  • 389
  • 390
  • 391
  • 392
  • 393
  • 394
  • 395
  • 396
  • 397
  • 398
  • 399
  • 400
  • 401
  • 402
  • 403
  • 404
  • 405
  • 406
  • 407
  • 408
  • 409
  • 410
  • 411
  • 412
  • 413
  • 414
  • 415
  • 416
  • 417
  • 418
  • 419
  • 420
  • 421
  • 422
  • 423
  • 424
  • 425
  • 426
  • 427
  • 428
  • 429
  • 430
  • 431
  • 432
  • 433
  • 434
  • 435
  • 436
  • 437
  • 438
  • 439
  • 440
  • 441
  • 442
  • 443
  • 444
  • 445
  • 446
  • 447
  • 448
  • 449
  • 450
  • 451
  • 452
  • 453
  • 454
  • 455
  • 456
  • 457
  • 458
  • 459
  • 460
  • 461
  • 462
  • 463
  • 464
  • 465
  • 466
  • 467
  • 468
  • 469
  • 470
  • 471
  • 472
  • 473
  • 474
  • 475
  • 476
  • 477
  • 478
  • 479
  • 480
  • 481
  • 482
  • 483
  • 484
  • 485
  • 486
  • 487
  • 488
  • 489
  • 490
  • 491
  • 492
  • 493
  • 494
  • 495
  • 496
  • 497
  • 498
  • 499
  • 500
  • 501
  • 502
  • 503
  • 504
  • 505
  • 506
  • 507
  • 508
  • 509
  • 510
  • 511
  • 512
  • 513
  • 514
  • 515
  • 516
  • 517
  • 518
  • 519
  • 520
  • 521
  • 522
  • 523
  • 524
  • 525
  • 526
  • 527
  • 528
  • 529
  • 530
  • 531
  • 532
  • 533
  • 534
  • 535
  • 536
  • 537
  • 538
  • 539
  • 540
  • 541
  • 542
  • 543
  • 544
  • 545
  • 546
  • 547
  • 548
  • 549
  • 550
  • 551
  • 552
  • 553
  • 554
  • 555
  • 556
  • 557
  • 558
  • 559
  • 560
  • 561
  • 562
  • 563
  • 564
  • 565
  • 566
  • 567
  • 568
  • 569
  • 570
  • 571
  • 572
  • 573
  • 574
  • 575
  • 576
  • 577
  • 578
  • 579
  • 580
  • 581
  • 582
  • 583
  • 584
  • 585
  • 586
  • 587
  • 588
  • 589
  • 590
  • 591
  • 592
  • 593
  • 594
  • 595
  • 596
  • 597
  • 598
  • 599
  • 600
  • 601
  • 602
  • 603
  • 604
  • 605
  • 606
  • 607
  • 608
  • 609
  • 610
  • 611
  • 612
  • 613
  • 614
  • 615
  • 616
  • 617
  • 618
  • 619
  • 620
  • 621
  • 622
  • 623
  • 624
  • 625
  • 626
  • 627
  • 628
  • 629
  • 630
  • 631
  • 632
  • 633
  • 634
  • 635
  • 636
  • 637
  • 638
  • 639
  • 640
  • 641
  • 642
  • 643
  • 644
  • 645
  • 646
  • 647
  • 648
  • 649

User Manual
24-Port and 48-Port Gigabit Ethernet PoE+
Smart Switches with 4 SFP Ports and
Optional Remote/Cloud Management
GS728TPv3
GS728TPPv3
GS752TPv3
GS752TPPv3
NETGEAR, Inc.
350 E. Plumeria Drive
April 2023
San Jose, CA 95134, USA
202-12674-01