Netgear GSM7328FS GSM7352S Hardware manual

Netgear GSM7328FS - ProSafe Switch - Stackable Manual

Netgear GSM7328FS manual content summary:

  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 1
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA 201-10813-01 March 2006
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 2
    herein. Certificate of the Manufacturer/Importer It is hereby certified that the NETGEAR ProSafe 24-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed I/O Module Bays GSM7328S has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992.The
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 3
    be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or Canada. EN 55 022 Declaration of Conformance This is to certify that the NETGEAR ProSafe 24-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed I/O Module Bays GSM7328S
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 4
    : Publication Part Number: Publication Version Number GSM7328S and GSM7352S March 2006 managed switch • ProSafe 24-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed I/O Module Bays GSM7328S • ProSafe 48-Port 10/100/1000 L3 managed Stackable Switch with 4 High-speed Module Bays GSM7352S
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 5
    Manual Audience, Scope, Conventions, and Formats 1-1 Chapter 2 Introduction GSM7328S Front Panel and LEDs 2-1 GSM7328S Rear Panel 2-4 GSM7352S Front Panel and LEDs 2-4 GSM7352S Rear Panel 2-6 Safety Instructions to the Switch 3-10 RJ-45 Ports ...3-10 Connecting a Console to the Switch 3-11 i
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 6
    Chapter 4 Troubleshooting Troubleshooting Chart 4-1 Additional Troubleshooting Suggestions 4-2 Appendix A Technical Specifications ...A1 Appendix B Default Configuration Settings B1 ii Publication Version 1.0, March 2006
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 7
    1 About This Manual The Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide describes installation and basic troubleshoting for the NETGEAR® GSM7328S and GSM7352S switches. Audience, Conventions, Formats, and Scope This information in this guide is intended for
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 8
    Table 1-2. Manual Scope Product Version Manual Publication Date • ProSafe 24-Port 10/100 L3 managed Stackable Switch with 4 Gigabit Ports GSM7328S • ProSafe 48-Port 10/100 L3 managed Stackable Switch with 4 Gigabit Ports GSM7352S March 2006 Note: Product updates are available on the NETGEAR, Inc
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 9
    and increase productivity. This guide describes hardware installation and basic troubleshooting for the following NETGEAR switches: • ProSafe 48-Port 10/100/1000 L3 managed Stackable Switch with 4 High- speed Module Bays GSM7352S • ProSafe 48-Port 10/100/1000 L3 managed Stackable Switch with 4 High
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 10
    Switches GSM7328S and GSM7352S Hardware Installation Guide The module bays support any combination of either the ProSafe 24-Gigabit Stackable Module (AX742) or the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741). See "High-Speed I/O Module Bays" in Chapter 3. 1 LEDs RST RJ-45 jacks (reset button
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 11
    on the port. • Solid yellow: A valid 100 Mbps link is established on the port. • Solid green: A valid 1000 Mbps link is established on the port. Note: If port 21-24 media is changed to SFP, the RJ-45 LEDs l change to OFF status. SFP Ports (1Link/ACT LED per port) • Off: No SFP module link
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 12
    Guide GSM7328S Rear Panel The rear panel has two module bays, a console port, redundant power supply connector, and a standard AC power receptacle for the supplied power cord. The module bays support any combination of either the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or the ProSafe 24
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 13
    3 Switches GSM7328S and GSM7352S Hardware Installation Guide The table below describes the GSM7352S LEDs on the front of the switch. Table 2-2. GSM7352S LED Description LED Description ID This is the stack member ID (1-8) that the software assigns to the switch. Master • Green: The switch
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 14
    module bays, a redundant power supply connector, a console port, and a standard AC power receptacle for the supplied power cord. The module bays support any combination of either the ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or the ProSafe 24-Gigabit Stackable Module (AX742). See "High-Speed
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 15
    Switches GSM7328S and GSM7352S Hardware Installation Guide Safety Instructions service markings. - Do not service any product except as explained in your system documentation. see the appropriate section in your troubleshooting guide or contact your trained service provider. • Do not push any
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 16
    Switches GSM7328S and GSM7352S Hardware Installation Guide • To help avoid damaging your system, be sure that the voltage selection switch (if provided) on the power supply is set Do not modify power cables or plugs. Consult a licensed electrician or your power company for site modifications. •
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 17
    the SFP sockets • Rack-mounting kit • Null-modem serial cable (RS-232) with 9-pin connectors • NETGEAR CD: The CD contains - Configuration software - Documentation including the Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches, the Administration Manual for
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 18
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Protecting Against Electrostatic Discharge Warning You can do so by periodically touching an unpainted metal surface on the switch. You can also take the following steps to prevent damage from electrostatic discharge
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 19
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 4. Make sure that all items are present. See "Package Contents" on page 3-1. Note: If any item is found missing or damaged, contact your local NETGEAR reseller for replacement. 5. Inspect the products and
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 20
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Select a Location The switch can be mounted in a standard 19-inch (48.26-centimeter) rack, wallmounted, or left freestanding (placed on a tabletop). The site where you install the switch may greatly affect its
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 21
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Install the Switch You can install the switch on a flat surface or in a standard 19-inch rack. Installing the Switch on a Flat Surface The switch ships with four self-adhesive rubber footpads. Stick one rubber
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 22
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 4. Align the bracket and rack holes. Use two pan-head screws with nylon washers to fasten each bracket to the rack. 5. Tighten the screws with a No. 2 Phillips screwdriver to secure the switch in the rack. Check the
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 23
    Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide High-Speed I/O Module Bays The High-Speed I/O Module Bays can be used for inter-switch stacking or to install XFP 10-Gigabit Ethernet modules. If you want to do both, you can stack the switch using two 24-Gigabit Stackable Modules
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 24
    Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 2. To install additional Gigabit Ethernet modules, repeat step 1. High-Speed I/O Module Installation The High-Speed I/O Module Bays support ProSafe 10-Gigabit Ethernet XFP Adapter (AX741) or ProSafe 24-Gigabit Stackable Modules
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 25
    use a serial cable to connect the console to the master switch. This single console connection lets you manage all the switches in the stack. For information about working with the CLI, see the Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches on the NETGEAR CD
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 26
    plate and connect the RPS unit to the switch. After all connections are completed, apply power to the switch. Connecting Equipment to the Switch You can connect devices, a Gigabit Ethernet module, and/or a console to the switch. RJ-45 Ports The switch uses Auto Uplink technology, which enables you
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 27
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Connecting a Console to the Switch After you install the switch and apply power, you can connect to it with a terminal or workstation. You can use the Command Line Interface (CLI) to identify the IP address. If you
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 28
    are provided for this purpose: • Quick Install Guide: Explains basic setup and configuration (provided as both a print document and in PDF format on the NETGEAR CD). • Command Line Interface Reference for the ProSafe 7300S Series Layer-3 Stackable Switches: Gives detailed examples of how to use the
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 29
    comply with Ethernet specifications. See Appendix A. Check for a defective adapter card, cable, or port by testing it in an alternate environment where all products are functioning. File transfer is slow or performance degradation is a problem. Half- or full-duplex setting on the switch and the
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 30
    limitations. Switch Integrity You can verify the integrity of the switch by resetting the switch. To reset the switch, use the Tools> Reset command or remove AC power from the switch and then reapply AC power. If the problem continues, contact NETGEAR technical support. 4-2 Troubleshooting v1
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 31
    does not support auto-negotiation, the switch only determines the speed correctly and the duplex mode defaults to half-duplex. The fiber gigabit ports negotiate speed, duplex mode, and flow control, provided that the attached device supports auto-negotiation. Troubleshooting 4-3 v1.0, March
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 32
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide 4-4 Troubleshooting v1.0, March 2006
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 33
    Technical Specifications Feature IEEE Network Protocol and Standards compatibility Switch management GSM7328S GSM7352S 802.3 10BASE-T 802.3u 100BASE-TX 802.3z 1000BASE-SX 802.3z 1000BASE-LX 802.3ab 1000BASE-T 802.3ae 10000BASE-LR 802.3ae 10000BASE-SR 802.3x flow control • Port mirroring support
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 34
    either 10-Gigabit Ethernet or 24-Gigabit stacking connectivity • RS-232 console port Bandwidth 144 Gbps 196 Gbps Address database size 8,000 media access control (MAC) addresses per system 10/100/1000 buffer memory 10/100/1000 buffer memory: 8-MB embedded memory for 24 ports Max support 0.75
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 35
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Table A-1. Technical Specifications Feature GSM7328S GSM7352S Environment Electromagnetic emissions and immunity Safety • Operating temperature: 32° to 122°F (0° to 50°C) • Storage temperature: - 4° to 158°F
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 36
    Managed Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide A-4 Technical Specifications v1.0, March 2006
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 37
    full duplex) Disabled Broadcast storm control Enabled Gigabit port type Auto detect Management IP configuration DHCP Password protection Disabled User name Admin Password (none) Web access Enabled Java mode Enabled VLAN All ports belong to default VLAN (VLAN 1) as untagged ports IP
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 38
    Stackable Layer 3 Switches GSM7328S and GSM7352S Hardware Installation Guide Table B-1. Default Configuration Settings (continued) Features IP routing RIP MAC address aging OSPF SNMP community DHCP Server VLAN Ingress filtering IP multicast filtering VRRP Default Setting Disabled Disabled 300
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 39
  • Netgear GSM7328FS | GSM7352S Hardware manual - Page 40
    NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA March 2006
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

201-10813-01
March 2006
NETGEAR
, Inc.
4500 Great America Parkway
Santa Clara, CA 95054 USA
Managed Stackable Layer 3
Switches GSM7328S and
GSM7352S Hardware
Installation Guide