Oki LD620D LD620 Unified Label Utility-II Manual Technical Reference
Oki LD620D Manual
View all Oki LD620D manuals
Add to My Manuals
Save this manual to your list of manuals |
Oki LD620D manual content summary:
- Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 1
LD620D Unified Label Utility-II Manual Technical Reference - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 2
Operating System Environment 4 3. Usage Preparation ...4 4. Unified Label Utility-II Usage 5 4-1 User Setting Manager 5 4-2 Configure Print Quality 11 4-3 Manual Calibration...12 4-4 PCX File Downloader 13 4-5 File Transfer...15 4-6 Printer Tools...16 4-7 Communication Window 17 4-8 SLCS Test - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 3
for test printing. This function is also used to read data response from printer. 8) SLCS Test Tool This function is used to test printing-related commands of the SLCS and create a brief label sample for test printing. We at Oki Data maintain ongoing efforts to enhance and upgrade the functions and - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 4
LD620D 2. Operating System Environment Unified Label Utility-II run on any of the following operating systems. PC Connection. Connect the printer and PC via the interface cable. (The interfaces available for usage are Serial, Parallel, USB and Ethernet.) 2) Unified Label Utility-II Program Execution - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 5
LD620D 4. Unified Label Utility-II Usage 4-1 User Setting Manager This function is used to change default settings of the printer, including code pages, serial settings, paper size, and print density, to values suited to the user environment. Click the "Configure Printer Setting". 4-1-1 Serial - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 6
Setting 1) Click the "Basic" Tab to configure speed, darkness and Media options. LD620D 2) Click the "Get" button to read the printer setting value. 3) Modify each value. 4) If you want to lock the setting value check the lock checkbox. 5) Click the "Set to Printer" to apply changed values to - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 7
4-1-3 Advanced Settings 1) Click the "Advanced" tab to configure Meida handling process options. LD620D 2) Click the "Get" button to read the printer setting value. 3) Modify each value. 4) Click the "Set to Printer" to apply changed values to printer. Rev. 1.1 - 7 - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 8
4-1-4 Real-time Clock 1) Click the "Real-time Clock" tab to set Real-Time Clock. LD620D 2) Configure the clocks and click the "Set to Printer" to apply to printer. Rev. 1.1 - 8 - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 9
LD620D 4-1-5 Language 1) Click the "Language" tab to set Default Codepage, Default International Character set. 2) Click the "Get" button to read the printer setting value. 3) Modify each value. 4) Click the "Set"button to apply changed values to printer. Rev. 1.1 - 9 - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 10
LD620D 4-1-6 Others 1) Click the "Others" tab to set printer information, initialize Motor, TPH, Cutter statistic and set USB serial number. 2) Click the "Get" button to read the printer information value. 3) Click the "Init Motor Stat", "Init TPH Stat", "Init Cutter Stat" to initialize each value. - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 11
with best printng quality among the printed labels. 4) Click the "Set to Printer" button to apply to printer. - Manually select Speed and Darkness 1) Choose speed and darkness manually. 2) Click "Print Sample label(s)" button to print label with the selected values. 3) After fiding optimal value - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 12
LD620D 4-3 Manual Calibration Manual-calibration of media detection can be used when the printer cannot detect a media gap (or black mark) even after auto-calibration has been executed. Users can calibrate sensor parameters in detail. Please make sure the printer is connected and execute the utility - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 13
LD620D 4-4 PCX File Downloader This function is used when saving a black-and the image to be deleted and click the Delete Image button. 3) To delete all images stored in the printer memory, click the Delete All Images button without entering an image name. 4-4-3 Image Information (II) Information for - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 14
LD620D Rev. 1.1 - 14 - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 15
LD620D 4-5 File Transfer This function is used when sending test files, such as command scripts, to the printer. 1) Click "Send File" button on the main window. 2) Select the file to be sent and click the "Download" button to send the file to the printer. Rev. 1.1 - 15 - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 16
4-6 Printer Tools LD620D - Print configuration label: To print out printer's configuration infomation. - Feed one label: To feed one blank label. - Print object list: To printout the fonts list and memory informations. - Calibration media: To execute auto-calibration to calibrate media sensor. - - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 17
LD620D 4-7 Communication Window This function is used to test commands or create sample labels. Type the command script in the edit window or open the saved command script. Responsed data from printer can be read with this program. 1) Click the "Communication Tool" on the main window to start this - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 18
LD620D 4-8 SLCS Test Tool This function is used to test printing-related commands of the SLCS and create a brief label sample for test printing. 1) Click the "SLCS Test Tool" button. 2) Click the "Multi Send" button to send data to printer. 3) If the command which request response from printer to - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 19
LD620D 5) The function of each button is described as follows a) Line & Box: creates a command for margin and width and length of print paper setting j) Check Printer Status: check cover, paper, and error status of printer k) SLCS Command Edit: function for command cutting, copying, pasting, and - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 20
.pt E-mail : [email protected] Oki Service Serviço de apoio técnico ao Cliente Tel: 808 200 197 E-mail : [email protected] OKI Europe Ltd. (Russia) Office 702, Bldg 1 Zagorodnoye shosse 117152, Moscow Tel: +74 095 258 6065 Fax: +74 095 258 6070 e-mail: [email protected] Website: www.oki.ru Technical support: Tel - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 21
om Oki produkter [email protected] för teknisk support gällandes Oki produkter Tel: 1-800-654-3282 Tel: (852) 3543 9288 Fax: 1-856-222-5247 Fax: (852) 3549 6040 http://WWW.OKIPRINTINGSOLUTIONS.COM http://www.okiprintingsolutions.com.hk http://my.okidata.com Oki Data(Australia) Pty Ltd. Oki Data - Oki LD620D | LD620 Unified Label Utility-II Manual Technical Reference - Page 22
Oki Data Corporation 4-11-22 Shibaura, Minato-ku,Tokyo 108-8551, Japan www.okiprintingsolutions.com
LD620D
Unified Label Utility-II Manual