Olympus 101200 Instruction Manual

Olympus 101200 - OM System 4Ti SLR Camera Manual

Olympus 101200 manual content summary:

  • Olympus 101200 | Instruction Manual - Page 1
    INSTRUCTIONS
  • Olympus 101200 | Instruction Manual - Page 2
    . We recommend that before using the camera, you read this instruction manual carefully, confirming the instructions on the camera so that you can get the very best performance and service life from your new camera. Note: All the components of the Olympus OM-4T are carefully designed and their
  • Olympus 101200 | Instruction Manual - Page 3
    Control 32 Shadow Control 35 < Taking Photographs ( I I I ) > - Automatic Exposure - How to Use the Exposure Memory Lock System 39 < Taking Photographs (IV) > - Manual Exposure - How to Take Picture on CenterWeighted, Averaged Metering 44 How to Use the Spot Measurement 46 < Taking Photographs
  • Olympus 101200 | Instruction Manual - Page 4
    < Preparations before Taking Pictures > 3
  • Olympus 101200 | Instruction Manual - Page 5
    Dioptric Correction The OM-4T permits dioptric adjustment according to your eyesight. Remove the body cap. 4
  • Olympus 101200 | Instruction Manual - Page 6
    Pull out the diopter adjustment knob. Turn and adjust the knob so that the matscreen appears sharp. Push the knob back in until it locks. 5
  • Olympus 101200 | Instruction Manual - Page 7
    Mounting the Lens Remove the rear lens cap. Align the red dots and rotate the lens clockwise until it locks. 6
  • Olympus 101200 | Instruction Manual - Page 8
    Remove the front lens cap. (Press in the mount tabs on the edges of the lens cap parallel with "OLYMPUS"). Removing the Lens: Press the lens release button and turn the lens counter-clockwise. 7
  • Olympus 101200 | Instruction Manual - Page 9
    Loading the Batteries Do not use different types of batteries or new and old batteries at the same time. If you are not likely to use the camera for a long period of time, remove the batteries before putting it away. Remove the battery cover. 8
  • Olympus 101200 | Instruction Manual - Page 10
    Wipe battery surfaces clean. Make sure that + signs are facing upwards. Checking the Batteries Always check the batteries after inserting new batteries, when shooting in cold weather, or if the camera has not been used for a long time. 9
  • Olympus 101200 | Instruction Manual - Page 11
    Rotate the mode selector dial to the "BATTERY CHECK" position. The audible and visual signals will tell you that the batteries have enough power. As the battery power weakens, the signals will become intermittent then vanish completely when they are exhausted. Replace the batteries. 10
  • Olympus 101200 | Instruction Manual - Page 12
    After the check, set back the dial. When checking the batteries, the audible and visual signals will automatically turn off in 30 seconds. If you then press the shutter release, the shutter will trip in the auto exposure mode. Loading the Film 11
  • Olympus 101200 | Instruction Manual - Page 13
    Pull up on the rewind knob to open the camera back. Tear off the top of the film box and insert it into the memo holder. It will remind you which film you are using. Insert the cartridge and push down the film rewind knob. (Always load the film in the shade.) 12
  • Olympus 101200 | Instruction Manual - Page 14
    Insert the film leader into the take-up spool. Wind the film and make sure the sprocket teeth catch both the upper and lower film perforations. Take up the slack by turning the rewind crank clockwise. 13
  • Olympus 101200 | Instruction Manual - Page 15
    Close the camera back until it clicks into place. Face the camera toward light and take two blind shots. This will bring the film to the first frame. 14
  • Olympus 101200 | Instruction Manual - Page 16
    Setting the ISO Film Speed Lift up the outer collar and rotate until the ISO speed appears in the window. Film speed 15
  • Olympus 101200 | Instruction Manual - Page 17
    Align the exposure line A with the index B . If the exposure compensation dial does not turn to the desired ISO number, set it once at an intermediate value then repeat the procedure. 16
  • Olympus 101200 | Instruction Manual - Page 18
    < Taking Photographs (I) > - Automatic Exposure - The OM-4T enables aperture-preferred automatic exposure on TTL direct light metering (center-weighted, averaged light metering). This mode can be used for most of the subjects under normal conditions - when shooting with the sun behind you, when the
  • Olympus 101200 | Instruction Manual - Page 19
    TTL Direct Light Metering Aperture-preferred automatic exposure allows you to take pictures by utilizing the lens depth of field effect (blurred background, for example). P. 95 Set the mode selector lever to the "AUTO" position. 18
  • Olympus 101200 | Instruction Manual - Page 20
    Set the aperture. Reference P. 117 Basic aperture settings; Press the shutter release lightly to activate the viewfinder display. The bar tip indicates the shutter speed. 19
  • Olympus 101200 | Instruction Manual - Page 21
    Focus on your subject. Press the shutter release to take the picture. A built-in battery conserver turns off the viewfinder display after 120 sec. 20
  • Olympus 101200 | Instruction Manual - Page 22
    If you see an overexposure warning signal ("OVER" blinks), set the aperture to a larger number. If the shutter speed is too slow, set the aperture to smaller number to prevent camera shake. 21
  • Olympus 101200 | Instruction Manual - Page 23
    Rewinding the Film When the exposure counter indicates the end of your roll of film. Push the "R" button. 22
  • Olympus 101200 | Instruction Manual - Page 24
    Fold out the rewind crank and wind it until the film tension is released. Open the camera back by pulling up on the rewind knob and remove the film. 23
  • Olympus 101200 | Instruction Manual - Page 25
    Taking Photographs (II) - Automatic Exposure - The spot metering system of the OM-4T enables you to control the exposure as you like. It insures perfect exposure of backlighted and high contrast subjects and expands shooting possibilities in the auto mode for more creative photography. 24
  • Olympus 101200 | Instruction Manual - Page 26
    How to Use the Spot Measurement Reference P. 96-100 Align the microprism area with the area you want to measure. (The spot metering range is outlined by the outer edge of the microprism.) Spot metering range 25
  • Olympus 101200 | Instruction Manual - Page 27
    hear an electronic sound and the word "SPOT" will appear in the viewfinder. The metered value is displayed by the mark. If you shift the camera, another mark will indicate the exposure value in the center of the frame along with the spot metered value. 26
  • Olympus 101200 | Instruction Manual - Page 28
    Press the shutter release to take the picture. The subject will turn out correctly exposed, regardless of the brightness of the background. The spot metering mode will be automatically cleared after the shutter has tripped, or after 120 seconds have passed, and it will return to the, TTL direct
  • Olympus 101200 | Instruction Manual - Page 29
    How to Clear the Spot Metering With the lever at "CLEAR", the mode will return to TTL direct light metering. "SPOT" and mark disappear. 28
  • Olympus 101200 | Instruction Manual - Page 30
    How to Use the "Multi-Spot Measurement" Mode Spot metering is possible in up to 8 spots. Reference P. 101-104 This sample photo shows a backlighted subject. 29
  • Olympus 101200 | Instruction Manual - Page 31
    Take spot metering on the face (first spot). Take spot metering on the ship in the background (second spot). 30
  • Olympus 101200 | Instruction Manual - Page 32
    Compose your picture and press the shutter release. Both the subject and the background are correctly exposed. To cancel the metered value, operate the clear lever. 31
  • Olympus 101200 | Instruction Manual - Page 33
    Highlight Control If you want to render white objects in white... Reference P. 105-106 In ordinary shooting, white objects will turn out grayish if the picture is taken in strong brightness over the entire frame.. 32
  • Olympus 101200 | Instruction Manual - Page 34
    Take spot metering on the part of the subject which you want to render in white. Press the HI. LIGHT button. Exposure will be automatically corrected to give 2-step overexposure. 33
  • Olympus 101200 | Instruction Manual - Page 35
    Press the shutter release to take the picture. The white object turns out white. The highlight control is cleared by pressing the HI. LIGHT button once again. To cancel the metered value, use the clear lever. 34
  • Olympus 101200 | Instruction Manual - Page 36
    Shadow Control If you want to render black objetcts in black... Reference P. 107-108 In ordinary shooting, black objects will turn out grayish if it is very dark over the entire picture frame. 35
  • Olympus 101200 | Instruction Manual - Page 37
    Take spot metering on the spot which you want to render in black. Press the SHADOW button. Exposure will be automatically corrected to give 2 2/3step underexposure. 36
  • Olympus 101200 | Instruction Manual - Page 38
    Press the shutter release to take the picture. The black object turns out black. The shadow control is cleared by pressing the SHADOW button once again. To cancel the metered value, use the clear lever. 37
  • Olympus 101200 | Instruction Manual - Page 39
    exposed with a very different exposure value if it is taken in different backgrounds. The OM-4T has an exposure memory lock system to solve this problem. It can be used in both the TTL direct metering and spot metering modes. Once an exposure value stored in memory, it does not vary
  • Olympus 101200 | Instruction Manual - Page 40
    How to Use the Exposure Memory Lock System Reference P. 109-110 The memory lock system is convenient for taking many pictures of the same subject in different backgrounds or costumes. Operate the lever to set up the memory mode. The letters "MEMO" will appear in the viewfinder and the memory signal
  • Olympus 101200 | Instruction Manual - Page 41
    Frame the composition as you desire. The Exposure Value is Stored in Memory after Shooting. 40
  • Olympus 101200 | Instruction Manual - Page 42
    The memory will keep on for 60 minutes after the shutter has tripped. Change the composition and shoot. The subject is exposed with the same exposure value even if you change the composition. 41
  • Olympus 101200 | Instruction Manual - Page 43
    To clear the memory, use the clear lever. The memory is also cleared in the following cases: 1. When a lens is mounted or dismounted. 2. When the mode lever is switched. 42
  • Olympus 101200 | Instruction Manual - Page 44
    Taking Photographs (IV) - Manual Exposure - The OM-4T permits manual exposure on center-weighted, averaged metering and spot metering. It allows you to choose the optimum aperture and shutter speed which suit your subject and taste. 43
  • Olympus 101200 | Instruction Manual - Page 45
    How to Take Pictures on Center-Weighted, Averaged Metering Set the mode selector dial to the "MANUAL" position. 44
  • Olympus 101200 | Instruction Manual - Page 46
    Set the bar graph tip to the fixed point between the arrows by adjusting the aperture and/or shutter speed rings. Fixed point The shutter speed you have set will be displayed in the viewfinder. Shoot. 45
  • Olympus 101200 | Instruction Manual - Page 47
    How to Use the Spot Measurement Reference P. 96-100 Align the microprism area with the area you want to measure. Spot metering range 46
  • Olympus 101200 | Instruction Manual - Page 48
    Press the spot button to take meter reading. Set the bar graph tip to the fixed point between the arrows by adjusting the aperture and/or shutter speed rings. The shutter speed you have set will be displayed in the viewfinder. 47
  • Olympus 101200 | Instruction Manual - Page 49
    Shoot. The subject will turn out correctly exposed, regardless of the brightness of the background. It is also possible to use the multi-spot metering, highlight control and shadow control. In any case, correct exposure is obtained by simply setting the bar graph at the fixed point. 48
  • Olympus 101200 | Instruction Manual - Page 50
    < Taking Photographs (V) > - Flash Photography - The OM-4T is the perfect companion for the world's first Full Synchro Flash F280. Professional standards are within the reach of every owner, even during daylight synchro - flash photography - an area which has traditionally required considerable
  • Olympus 101200 | Instruction Manual - Page 51
    Taking Daylight Synchro-Flash Photographs (Super FP Flash Mode) For OTF Auto using the Normal OTF Flash mode, refer to the F280 instruction manual. Slide the F280 into the accessory shoe and secure it with the lock screw. 50
  • Olympus 101200 | Instruction Manual - Page 52
    Turn the power switch ON. Check the charge indicator. Set the mode switch to SUPER FP. 51
  • Olympus 101200 | Instruction Manual - Page 53
    Set the camera mode to AUTO. Select an aperture that results in a shutter speed faster than 1/60 sec. (for slower speeds consult the F280 manual). 52
  • Olympus 101200 | Instruction Manual - Page 54
    Press the shutter release. Confirm a correct exposure by checking the indicator. 53
  • Olympus 101200 | Instruction Manual - Page 55
    < Other Operations > 54
  • Olympus 101200 | Instruction Manual - Page 56
    Using the Self-Timer Push the lever down outward. Press the shutter release to start the self-timer. The shutter will fire in 12 seconds. The shutter will trip immediately if the self-timer lever is returned while it is running. 55
  • Olympus 101200 | Instruction Manual - Page 57
    Exposure Compensation Reference P. 116 When an exposure compensation is set, the indicator lights in the viewfinder. After shooting, return the dial to its original position. 56
  • Olympus 101200 | Instruction Manual - Page 58
    Bulb Exposure Reference P. 120 While pressing the "B" lock button, turn and set the shutter speed dial to "B". The display in the view finder disappears. 57
  • Olympus 101200 | Instruction Manual - Page 59
    The shutter will remain open as long as the shutter release button is held depressed. How to Shoot when the Batteries are Exhausted If the batteries are exhausted and you do want to take pictures immediately, use the mechanical shutter speed of 1/60 sec. 58
  • Olympus 101200 | Instruction Manual - Page 60
    While pressing the "B" lock button, rotate the shutter ring to the red "60" position. Shoot. The mechanical shutter will operate to trip at 1 /60 sec. You cannot use the motor drive, winders and flashes with the mechanical shutter. 59
  • Olympus 101200 | Instruction Manual - Page 61
    Using the Viewfinder Illuminator Push the button if the viewfinder display is too dark to read. 60
  • Olympus 101200 | Instruction Manual - Page 62
    How to Turn Off the Beeper To turn off the audible signal, push the lever to the right (in the direction of the arrow). You will no longer hear PCV sounds when turning on the spot metering, highlight and shadow controls, when operating the memory/clear lever, checking the batteries, or when mounting
  • Olympus 101200 | Instruction Manual - Page 63
    Changing the Focusing Screen 14 screens are available to cover a wide range of applications. Reference P. 139-140 Pull down the screen frame. Pull the lug at top inside the body mount toward you to swing down the screen frame. 62
  • Olympus 101200 | Instruction Manual - Page 64
    To change the focusing screen, use the tweezers supplied with an optional focusing screen. Push the frame upward until you hear a click. 63
  • Olympus 101200 | Instruction Manual - Page 65
    Changing the Camera Back The camera back is interchangeable with the Recordata Back or 250 Film Back. P. 133 Open the camera back. Press down on the camera back release button and remove the camera back. Removing Attaching 64
  • Olympus 101200 | Instruction Manual - Page 66
    Attaching the Grip Attach the Camera Grip 1 (optional accessory). When using a motor drive or winders, detach the Grip. 65
  • Olympus 101200 | Instruction Manual - Page 67
    Handling Care Take care in handling the camera. Do not use extra force. 66
  • Olympus 101200 | Instruction Manual - Page 68
    Storage Care Guard against high temperatura and magnetic fields. Battery Precaution 67
  • Olympus 101200 | Instruction Manual - Page 69
    Description of Controls 1 Finder Light Window 2 CLEAR/MEMORY Lever 3 Self-Timer/ Electronic Beeper Muffling Lever 4 Grip Lock Screw 5 Self-Timer/Battery Check Signal 68 6 TTL Auto Cord Socket 7 Shoulder Strap Eyelet 8 Lens 9 Lens Release Button 10 Depth of Field Scale 11 Aperture Ring 12 Focusing
  • Olympus 101200 | Instruction Manual - Page 70
    13 Automatic Clear Button 14 Accessory Shoe 15 Manual Shutter Speed Ring 16 Rewind Crank 17 Rewind Knob/ Camera Back Release 18 Film Speed Dial/Exposure Compensation Dial 19 ISO/ASA Film Speed Window 20 Mode Selector Lever 21 Dioptric Adjustment Knob 22 HI.
  • Olympus 101200 | Instruction Manual - Page 71
    34 Viewfinder Eyepiece Frame 35 Film Rewind Shaft 38 Sprocket 39 Film Take-up Spool 40 Camera Back Release Pin 41 Camera Back 42 Pressure Plate 36 Film Chamber 37 Film Guide Pins 44 Shutter Curtain 70 43 Film Cartrige Pressure Spring 45 Recordata Back Contact
  • Olympus 101200 | Instruction Manual - Page 72
    52 Lens Mount Ring 53 Motor Guide Pin Hole 46 B Lock Button 47 Flash Synchronization Socket 48 Tripod Socket 49 Motor Coupling Terminals 50 Motor Coupling Socket 51 Battery Chamber 71
  • Olympus 101200 | Instruction Manual - Page 73
    Type: TTL auto-exposure 35mm SLR camera Film Format: 24mm x 36mm Lens mount: Olympus OM mount Shutter: Electronically controlled cloth exposure memory control: Exposure value memory system (60 min. limiter) Manual exposure control: B, 1 sec.~1/2000 sec. mechanical exposure speed 1/60
  • Olympus 101200 | Instruction Manual - Page 74
    CO., LTD. San-Ei Building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku Tokyo, Japan Tel. 0 3 - 3 4 0 - 2 2 1 1 OLYMPUS CORPORATION Crossways Park, Woodbury, New York 11797, U.S.A. Tel. 516-364-3000 OLYMPUS OPTICAL CO. (EUROPA) GMBH Postfach 104908, Wendenstrasse 14-16, 2 Hamburg 1, West Germany. Tel
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

INSTRUCTIONS