    INSTRUCTION MANUAL Automatic Blood Pressure Monitor Model BP710 ENGLISH ESPAÑOL
  • Omron BP710 | Instruction Manual - Page 2
    the Monitor Introduction ...3 Safety Information 4 Operating the Device 4 Care and Maintenance 5 Operating Instructions Before Taking a Measurement 6 Know Your Unit ...7 Unit Display ...8 Display Symbols 9 Irregular Heartbeat Symbol 9 Heartbeat Symbol/Hypertension
  • Omron BP710 | Instruction Manual - Page 3
    need a stethoscope so the monitor is simple to use. The BP710 comes with the following components: • Monitor • Standard Adult Arm Cuff • Instruction Manual printed in English and Spanish • Quick Start Guide The BP710 IntelliSense® Automatic Inflation Blood Pressure Monitor is intended for home use
  • Omron BP710 | Instruction Manual - Page 4
    of clean water. Contact a physician immediately. Read all of the information in the instruction manual and any other literature in the box before operating the unit. This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants
  • Omron BP710 | Instruction Manual - Page 5
    not subject the monitor to strong shocks, such as dropping the unit on the floor. Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by the manufacturer will void the user warranty. Do not
  • Omron BP710 | Instruction Manual - Page 6
    arm on table so that the cuff is at the same level as your heart. 6. Remain still and do not talk during the measurement. 7. Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase
  • Omron BP710 | Instruction Manual - Page 7
    Air tube Standard Adult Arm Cuff Air plug INSTRUCTION MANUAL Automatic Blood Pressure Monitor Model BP710 INTRODUCTION Thank you for purchasing the OMRON® BP710 Automatic Blood Pressure Monitor. Fill in for future reference. DATE PURCHASED SERIAL NUMBER Instruction Manual Quick Start Guide 7
  • Omron BP710 | Instruction Manual - Page 8
    UNIT DISPLAY Systolic blood pressure Diastolic blood pressure Memory symbol (Displayed when viewing values stored in memory) Irregular Heartbeat symbol Heartbeat symbol Pulse display Deflation symbol Battery low indicator 8
  • Omron BP710 | Instruction Manual - Page 9
    monitor is measuring the systolic and diastolic Blood pressure blood pressure. If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your Irregular Heartbeat Short Long Pulse physician. Follow the directions of your doctor. Blood pressure
  • Omron BP710 | Instruction Manual - Page 10
    specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. Omron Healthcare recommends you contact your physician if the Heartbeat Symbol ( ) flashes on the display
  • Omron BP710 | Instruction Manual - Page 11
    on the battery cover and slide the cover off in the direction of the arrow. 2. Install 4 "AAA" size batteries so Replace the battery cover. BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display, turn the monitor off and remove all the batteries. Replace
  • Omron BP710 | Instruction Manual - Page 12
    APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons
  • Omron BP710 | Instruction Manual - Page 13
    THE RIGHT ARM When taking a measurement using the right arm, use this instruction for Step 3. Apply the cuff to your right upper arm so the arrow and the air tube runs along the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow. Right Arm Arrow NOTE: Be
  • Omron BP710 | Instruction Manual - Page 14
    turn off. 3. Inflation stops automatically and the measurement is started. As the cuff deflates, decreasing numbers appear on the display and the Heartbeat Symbol ( ) flashes. 4. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed
  • Omron BP710 | Instruction Manual - Page 15
    the START/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure. NOTES: • Do not apply more pressure than necessary. • The monitor will not inflate above 299 mmHg. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and
  • Omron BP710 | Instruction Manual - Page 16
    monitor stores the blood pressure and pulse rate in the memory. The monitor automatically stores up to 14 sets of measurement values (systolic pressure, diastolic pressure rate is displayed. The newest set is numbered "1". 2. Press the START/STOP button to turn the unit off. TO DELETE ALL THE VALUES
  • Omron BP710 | Instruction Manual - Page 17
    CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or
  • Omron BP710 | Instruction Manual - Page 18
    SYMBOL ERROR INDICATORS CAUSE Monitor could not detect pulse wave. Cuff under-inflated. Cuff not applied correctly. Cuff over-inflated. CORRECTION Take another measurement and remain still until the measurement is complete. Remove the arm cuff. Read "Taking a Measurement". Wait 2-3 minutes. Take
  • Omron BP710 | Instruction Manual - Page 19
    TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low. Blood pressure varies constantly
  • Omron BP710 | Instruction Manual - Page 20
    energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the
  • Omron BP710 | Instruction Manual - Page 21
    Your BP710 IntelliSense® Automatic Blood Pressure Monitor, excluding the arm cuff, is warranted to be free from defects in materials and workmanship appearing within 2 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The arm cuff is
  • Omron BP710 | Instruction Manual - Page 22
    Range: Accuracy/Calibration: Inflation: Deflation: Rapid Air Release: Measurement Method: Power Source: Battery Life: Operating Temperature / Humidity: Storage Temperature / Humidity/Air Pressure: Main Unit Weight: Main Unit Dimensions: Cuff Size: Cuff Circumference: BP710 (HEM-7113
  • Omron BP710 | Instruction Manual - Page 23
    SPECIFICATIONS Memory: Contents: Optional Accessories: Up to 14 readings Main Unit, Standard Adult Arm Cuff, Instruction Manual, and Quick Start Guide Large Cuff 13" - 17" (320 mm - 420 mm) = Type B NOTE: These specifications are subject to change without notice. 23
  • Omron BP710 | Instruction Manual - Page 24
    Omron Healthcare, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www.omronhealthcare.com Copyright © 2010 Omron Healthcare, Inc. Made in China 5325502-1B
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

ESPAÑOL
ENGLISH
Automatic
Blood Pressure Monitor
Model BP710
INSTRUCTION MANUAL