Oregon Scientific BAR908HGA User Manual

Oregon Scientific BAR908HGA Manual

Oregon Scientific BAR908HGA manual content summary:

  • Oregon Scientific BAR908HGA | User Manual - Page 1
    EN Metal Weather Station Model: BAR908HG / BAR908HGU / BAR908HGA User Manual Set Daily Alarm 12 Set Pre-Alarm 13 Activate Alarm 13 Snooze 13 Barometer 13 CONTENTS View Index 17 Set Clock 12 Reset System 17 Switch Clock Display 12 Precautions 17 Alarms 12 Troubleshooting 18 1
  • Oregon Scientific BAR908HGA | User Manual - Page 2
    EN Specifications 18 About Oregon Scientific 20 EU-Declaration of Conformity 20 FCC Statement 20 Declaration of Conformity 21 2
  • Oregon Scientific BAR908HGA | User Manual - Page 3
    PRODUCT OVERVIEW FRONT VIEW 1 2 3 4 1. Weather Forecast Area: Animated weather forecast 2. Temperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings
  • Oregon Scientific BAR908HGA | User Manual - Page 4
    EN BACK VIEW 1 2 3 4 10 11 12 13 1. ALARM: View alarm status; set alarm 2. SELECT: Switch Areas 3. UP: Increase setting / activate radio-controlled clock 4. CHANNEL: Switch remote sensor display 5. MODE: Change settings / display 6. HISTORY: View historical barometer and UV readings 5 7.
  • Oregon Scientific BAR908HGA | User Manual - Page 5
    LCD DISPLAY Weather Forecast Area 1 2 1. Low battery icon for main unit 2. Weather display Temperature / Humidity / Comfort Zone Area 1 2 8 3 9 4 5 10 6 11 7 1. Selected Area icon 2. Heat Index 3. Indoor / Outdoor channel number (IN, 1-5) / reception status 4. Low battery icon for
  • Oregon Scientific BAR908HGA | User Manual - Page 6
    calendar 5. UV exposure time countdown has started 6. UV index level 7. UV exposure time for user 8. Barometer / UV chart 9. SPF applied to user for UV exposure 10. User skin type for UV exposure 11. User number (for UV Mode) or hour history for UV / Barometric pressure reading 12. Altitude
  • Oregon Scientific BAR908HGA | User Manual - Page 7
    REMOTE SENSOR RTGN318 / RTGN318D 5 1 2 6 3 4 1. RESET 2. EU / UK radio signal format switch (RTGN318D only) 3. Double sided adhesive tape 4. CHANNEL switch (1-5) 5. Wall mount 6. Battery compartment 7 EN
  • Oregon Scientific BAR908HGA | User Manual - Page 8
    EN RTGN318A 4 1 5 2 3 1. RESET 2. Double sided adhesive tape 3. CHANNEL switch (1-5) 4. Wall mount 5. Battery compartment 8
  • Oregon Scientific BAR908HGA | User Manual - Page 9
    EN GETTING STARTED adaptor should be disconnected from the main unit. BATTERIES Batteries are supplied with this product: • Main unit 3 x UM-4 (AAA) 1.5V • Remote unit 1 x UM-3 (AA) 1.5V NOTE The main unit and adaptor should not be exposed to wet conditions. No objects filled with liquid,
  • Oregon Scientific BAR908HGA | User Manual - Page 10
    EN 2. Insert the batteries. signal transmission. 3. Set the channel and radio signal format (RTGN318D only). The switches are located in the battery compartment. SWITCH OPTION NOTE The transmission range may vary and is subject to the receiving range of the main unit. You may need to
  • Oregon Scientific BAR908HGA | User Manual - Page 11
    RTGN318D / RTGN318A remote sensor, or manual settings that you enter. Once complete, sensor RTGN318 / RTGN318D / RTGN318A. • BAR908HG (RTGN318): DCF-77 signal: within 1500 km signal: within 1500 km (932 miles) of Anthorn, England. • BAR908HGA (RTGN318A): WWVB-60 signal: within 3200 km (2000 miles)
  • Oregon Scientific BAR908HGA | User Manual - Page 12
    RADIO-CONTROLLED CLOCK ON / OFF If you wish to manually set the clock, you must first disable the radio display language. 4. Press UP or DOWN to change the setting. 5. Press MODE to confirm. BAR908HGA: Select the time zone: (0) Pacific, (+1) Mountain, (+2) Central or (+3) Eastern. NOTE The language
  • Oregon Scientific BAR908HGA | User Manual - Page 13
    EN 4. Select the hour and minute. Press UP or DOWN to change settings. 5. Press ALARM to confirm. 6. The Daily Alarm icon will appear when the alarm is set. SET PRE-ALARM The Pre-Alarm can be set to sound 15, 30, 45, or 60 minutes before the Daily Alarm. It will sound whenever the recorded
  • Oregon Scientific BAR908HGA | User Manual - Page 14
    EN 2. Press and hold HISTORY for 2 seconds. 3. Press UP or DOWN to set the altitude in 10-metre increments (-100m to 2500m). 4. Press HISTORY to confirm. SELECT MEASUREMENT UNIT Slide the mb / inHg switch (in the clock battery compartment), to change the display unit. VIEW BAROMETER HISTORY
  • Oregon Scientific BAR908HGA | User Manual - Page 15
    Violet Radiation Sensor is available as an optional item for BAR908HG / BAR908HGU / BAR908HGA. The UV sensor gives you the following information at Exposure Time Countdown Mode and start the exposure time countdown. The remaining user UV exposure time will display and the will flash. 7. When the
  • Oregon Scientific BAR908HGA | User Manual - Page 16
    EN MAXIMUM / MINIMUM MEMORY FOR UVI To view the maximum and minimum memory for UVI: 1. Press SELECT to navigate to the Barometer Area. 2. Press MODE to select the UV display. 3. Press MEM to show maximum, minimum and current UVI readings. 4. Press and hold MEM for 2 seconds to clear the UVI memory.
  • Oregon Scientific BAR908HGA | User Manual - Page 17
    . Do not mix new and old batteries. 1. Press SELECT to navigate to the Temperature Area. will show next to the Area. • Images shown in this manual may differ from the actual display. 2. Press MODE to reach the Heat Index display. • When disposing of this product, ensure it is collected 17
  • Oregon Scientific BAR908HGA | User Manual - Page 18
    this product and the contents of the user manual are subject to change without notice. NOTE Features and accessories will not be available in all countries. For more information, please contact your local retailer. TROUBLESHOOTING PROBLEM SYMPTOM REMEDY Barometer Strange readings Set altitude
  • Oregon Scientific BAR908HGA | User Manual - Page 19
    Weight Temperature Unit Indoor Range Outdoor Range Resolution Comfort Memory Relative Humidity Range Resolution Comfort Memory Barometer Unit Resolution Altitude Display (4.61 x 3.15 x 6.73 in) 80 g (2.82 oz) without battery °C or °F -5 °C to 50 °C (23 °F to 122 °F) -20 °C to 60 °C (-4 °F to 140
  • Oregon Scientific BAR908HGA | User Manual - Page 20
    BAR908HG / BAR908HGU / BAR908HGA) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. ABOUT OREGON SCIENTIFIC the user's
  • Oregon Scientific BAR908HGA | User Manual - Page 21
    instructions the user is encouraged service for all enquiries. We Name: Address: Telephone No.: Oregon Scientific, Inc. 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No.: BAR908HG / BAR908HGU / Product Name: Manufacturer: Address: Phase BAR908HGA
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

EN
1
CONTENTS
Product Overvi
ew
..........................................................
3
Front View
.....................................................................
3
Back View
.....................................................................
4
LCD Display
..................................................................
5
Remote Sensor
.............................................................
7
Getting Started
................................................................
9
Batteries
.......................................................................
9
AC Adaptor (Main Unit)
.................................................
9
Change Settings
...........................................................
9
Remote Sensor
................................................................
9
Set Up Thermo / Hygro Sensor
....................................
9
Sensor Data Transmission
.........................................
10
Search for Sensor
.......................................................
10
Clock and Calendar
.......................................................
11
Radio-Controlled Clock
...............................................
11
Turn Radio-Controlled Clock ON / OFF
......................
12
Set Clock
....................................................................
12
Switch Clock Display
..................................................
12
Alarms
............................................................................
12
Set Daily Alarm
...........................................................
12
Set Pre-Alarm
.............................................................
13
Activate Alarm
.............................................................
13
Snooze
.......................................................................
13
Barometer
......................................................................
13
View Barometer Area
..................................................
13
Select Measurement Unit
...........................................
14
View Barometer History
..............................................
14
Bar Chart Display
.......................................................
14
Set Altitude
.................................................................
14
Weather Forecast
..........................................................
14
Weather Forecast Icons
..............................................
14
UV Measurement
...........................................................
15
New Additional UV Features
.......................................
15
Temperature and Humidity
...........................................
16
View Temperature and Humidity Area
........................
16
Select Measurement Unit
...........................................
16
Select Sensor Channel
...............................................
16
Minimum / Maximum Records
....................................
16
Temperature and Humidity Trend
...............................
16
Comfort Zone
..............................................................
17
Heat Index
..................................................................
17
Reset System
.................................................................
17
Precautions
....................................................................
17
Troubleshooting
............................................................
18
Metal Weather Station
Model: BAR908HG / BAR908HGU /
BAR908HGA
User Manual