Oregon Scientific RAR501N User Manual

Oregon Scientific RAR501N Manual

Oregon Scientific RAR501N manual content summary:

  • Oregon Scientific RAR501N | User Manual - Page 1
    EN Multi-zone weather station Model: RAR501 / RAA501H USER MANUAL Index Overview 2 Front view 2 Back view 3 Sensor 3 Accessories - separate purchase required 4 Getting started 4 Remote sensor installation 4 Main unit installation 5 Synchronising and placing sensors 5 Name tags 6 Weather
  • Oregon Scientific RAR501N | User Manual - Page 2
    EN Overview Front view 1 2 3 4 5 6 3"3@*.@&/@3JOEE 1. Weather forecast 2. : mold alert 3. Main unit batteries low 4. Temperature and humidity for location where main unit is placed 5. Temperature and humidity for location where sensor is placed 6. Customisable name tags 2
  • Oregon Scientific RAR501N | User Manual - Page 3
    Back view 1 2 3 4 5 1. Wall mount hole 2. Battery compartment 3. Collapsible table stand 4. °C / °F: select temperature unit 5. RESET: reset unit to default settings 3"3@*.@&/@3JOEE Sensor This product can work with up to 3 sensors at any one time to capture temperature and relative
  • Oregon Scientific RAR501N | User Manual - Page 4
    EN 1. LCD display 2. LED status indicator 3. Wall mount hole 4. RESET 5. CHANNEL switch 6. Battery compartment THGN132N 2 1 3 1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole 5. CHANNEL switch 3"3@*.@&/@3JOEE Accessories - separate purchase required Optional
  • Oregon Scientific RAR501N | User Manual - Page 5
    EN Main unit installation 1. Remove the battery compartment. 2. Insert the batteries, matching the polarities. 3. Press RESET after each battery change. The battery icon areas: may appear in the following AREA Main unit environment area Remote sensor environment area MEANING Main unit batteries
  • Oregon Scientific RAR501N | User Manual - Page 6
    Weather forecast This product forecasts the next 12 to 24 hours of weather forecast within a 30-50 km (19-31 mile) radius. Weather below 60%. Troubleshooting DISPLAY LL.L LL HH.H HH AREA Temperature Humidity Temperature Humidity --.- or --% Temperature and Humidity PROBLEM Reading is below
  • Oregon Scientific RAR501N | User Manual - Page 7
    EN Reset Using a thin blunt instrument, press RESET to return to default settings. Signal frequency Number of channels 433 MHz (RAR501) / 315 MHz (RAA501H) 3 Specifications Main unit TYPE L x W x H Weight Signal frequency Temperature range Humidity range Power DESCRIPTION 134 x 27 x 134 mm (5.3
  • Oregon Scientific RAR501N | User Manual - Page 8
    on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information. • The contents of this manual may not be reproduced without the permission of the manufacturer. • Do not dispose
  • Oregon Scientific RAR501N | User Manual - Page 9
    that this Multi-zone weather station (Model: RAR501 / RAA501H) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service. FCC
  • Oregon Scientific RAR501N | User Manual - Page 10
    instead. We Name: Address: Telephone No.: Oregon Scientific, Inc. 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA 1-800-853-8883 declare that the product Product No.: RAR501 / RAA501H Product Name: Multi-zone weather station Manufacturer: Address: IDT Technology Limited Block C, 9/F, Kaiser
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10

EN
1
Multi-zone weather station
Model: RAR501 / RAA501H
USER MANUAL
INDEx
Overview
...................................................................
2
Front view
..............................................................
2
Back view
...............................................................
3
Sensor
....................................................................
3
Accessories – separate purchase required
............
4
Getting started
..........................................................
4
Remote sensor installation
.....................................
4
Main unit installation
..............................................
5
Synchronising and placing sensors
.......................
5
Name tags
..............................................................
6
Weather forecast
......................................................
6
Temperature and humidity
......................................
6
Mold alert
...............................................................
6
Troubleshooting
.....................................................
6
Reset
..........................................................................
7
Specifications
...........................................................
7
Precautions
...............................................................
8
About Oregon Scientific
..........................................
8
EU-Declaration of conformity
..................................
9
FCC statement
..........................................................
9
RAR501_IM_EN_R4.indd
1
12-6-15
δΈ‹εˆ2:30