Oregon Scientific SZ999 User Manual

Oregon Scientific SZ999 Manual

Oregon Scientific SZ999 manual content summary:

  • Oregon Scientific SZ999 | User Manual - Page 1
    the particular pairing instructions in the User Manual. If your TROUBLESHOOTING In the event that you experience a weak signal or your signal is disrupted by interference in the environment, follow the instructions unit contains no user-serviceable parts. • Take as contact for support or sales. Please
  • 1

JreGon
SC
I
ENT
I
F
I
C
Bluetooth
Smart
Fabric
Chest
Belt
Model:
SZ999
User
Manual
The
SZ999
water
resistant
fabric
chest
belt
is
equipped
with
the
latest
Bluetooth
Smart
technology
to
achieve
reliable
transmission
linkage
with
sports
system
device
that
is
with
the
logo
Oplutitoottr
and
corresponding
application.
EN
OVERVIEW
HEART
RATE
DETECTOR
Battery
compartment
To
replace
the
chest
belt
battery:
1.
Detach
the
heart
rate
detector
unit
from
the
belt
strap.
2.
Use
a
coin
to
open
the
battery
compartment
lid
by
turning
it
anticlockwise
to
open.
3.
Remove
the
old
battery
and
insert
a
new
CR2032,
3V
lithium
battery.
Make
sure
to
place
the
battery
in
the
compartment
following
the
polarity
+A.
4.
Secure
the
lid
by
turning
the
coin
clockwise.
C
Remember
to
set
the
profiles
after
every
battery
replacement
or
reset.
CARE
INSTRUCTIONS
The
belt
strap
can
be
hand
washed.
Remember
to
detach
the
heart
rate
detector
unit!
Do
not
wrap
the
detector
unit
in
a
wet
towel
nor
with
other
wet
materials.
Do
not
place
or
wash
the
heart
rate
detector
unit
under
running
water,
instead
clean
it
with
a
wet
cloth.
Properly
dry
the
detector
unit
immediately
after
use.
Snap
bu
one
Do
not
store
the
chest
belt
in
a
hot
(about
50°C)
and
humid
(about
90%)
environment.
front
view
back
view
Do
not
place
the
conductive
rubber
face
down
on
a
metal
table
or
surface.
Do
not
bleach,
dry
clean,
tumble
dry
or
iron
the
belt
strap.
BELT
STRAP
Snap
buttons
0
front
view
Conductive
pads
back
view
WEARING
THE
CHEST
BELT
1
he
chest
belt
counts
your
heartbeat
and
transmits
the
data.
1.
Align
the
heart
rate
detector
unit
with
the
snap
buttons
on
the
belt
strap.
Secure
by
snapping
into
place.
2.
Unfasten
the
belt
strap.
3.
Wet
the
conductive
pads
on
the
underside
of
the
chest
belt
with
a
few
drops
of
water
or
conductive
gel
to
ensure
solid
contact.
4.
Position
the
heart
rate
detector
unit
below
your
chest,
while
making
sure
logo
is
the
right
way
up.
Wrap
the
strap
around
your
chest
and
fasten
into
place.
To
ensure
an
accurate
heart
rate
signal,
adjust
the
strap
until
the
belt
sits
snugly
below
your
pectoral
muscles.
The
position
of
the
chest
belt
affects
its
performance.
Avoid
areas
with
dense
chest
hair.
In
dry,
cold
climates,
it
may
take
several
minutes
for
the
chest
belt
to
function
steadily.
This
is
normal
and
should
improve
with
several
minutes
of
exercise.
TRANSMISSION
SIGNAL
The
SZ999
chest
belt
can
be
paired
and
provide
heart
rate
readings.
Locate
your
chest
belt
close
to
your
device
to
help
achieve
pairing.
The
heart
rate
chest
belt
has
a
maximum
transmission
range
of
about
100
centimeters
(40
inches).
To
search
for
heart
rate
signal,
refer
to
the
instructions
of
your
device.
PAIR
WITH
OREGON
SCIENTIFIC
U
OOTH
SMART
SPORTS
SYSTEM
DEVICE
To
pair
with
Oregon
Scientific
Bluetooth
Smart
device
(such
as
SE900
or
RA900
Ssmart
Watch),
please
refer
to
the
particular
pairing
instructions
in
the
User
Manual.
If
your
sports
device
is
already
paired
with
a
chest
belt,
you
have
to
first
delete
the
chest
belt
before
you
are
able
to
pair
with
another
chest
belt.
kOit.
While
pairing,
make
sure
to
stay
away
from
other
devices
and
move
the
chest
belt
to
pair
close
to
your
device.
TROUBLESHOOTING
In
the
event
that
you
experience
a
weak
signal
or
your
signal
is
disrupted
by
interference
in
the
environment,
follow
the
instructions
below
to
identify
and
resolve
the
situation.
1.
The
signal
is
weak.
Shorten
the
distance
between
the
heart
rate
chest
belt
and
device.
Re
-adjust
the
position
of
the
heart
rate
chest
belt.
Check
the
conductive
pads
are
moist
enough
to
ensure
solid
contact.
Check
the
battery.
If
they
are
low
or
exhausted,
the
transmission
range
may
be
shortened.
Force
a
signal
search
on
the
watch.
2.
The
gym
equipment
does
not
seem
to
work
with
your
chest
belt.
Most
gym
equipment
is
compatible
with
analog
transmission.
This
chest
belt
does
not
transmit
an
analog
signal,
it
only
uses
the
low
energy
Bluetooth
Smart
technology.
3.
Signal
is
jammed
or
there
is
interference
from
another
person's
heart
rate
monitor:
There
is
too
much
interference
in
the
environment
for
your
heart
rate
monitor
to
function.
Move
to
an
area
where
the
watch
can
register
your
heart
rate
reading
and/or
force
another
signal
search.
man
Signal
interference
in
the
environment
can
be
caused
by
electromagnetic
disturbances.
These
may
occur
near
high
voltage
power
lines,
traffic
lights,
overhead
lines
of
electric
railways,
electric
bus
lines
or
trams,
televisions,
car
motors,
bike
computers,
some
motor
driven
exercise
equipment,
cellular
phones
or
when
you
walk
through
electric
security
gates.
Under
interference,
the
heart
rate
reading
may
become
unstable
and
inaccurate.
WATER
RESISTANCE
The
SZ999
is
water-resistant
up
to
10
meters
(32.8
feet).
Not
recommended
to
use
for
swimming.
r
ii
,
.............
L
-...,
RAIN
...........
arnytErcierimo
SHOWERING
(WAR81
/
COOL
WATER
ONLY)
LIGHT
SWIMMING/
SHALLOW
WATER
SHALLOW
DIVING/
SURFING/
WATER
SPORTS
SNORKELING/
DEEP
WATER
DIVING
10M
/
32.8
Fr
OK
NO
NO
NO
NO
Ensu
e
the
battery
compartment
is
secured
and
intact
before
exposing
to
excessive
water.
SPECIFICATIONS
Heart
rate
detector
dimension
(LxWxH)
66.1
x
38
x
12.5
mm
(2.6
x
1.5
x
0.49
inches)
Power
1
x
CR2032
3V
lithium
battery
Operating
temperature
5*C
to
40*C
(41T
to
104*F)
Storage
temperature
-20*C
to
60°C
(-4*F
to
140*F)
PRECAUTIONS
To
ensure
you
use
your
product
correctly
and
safely,
read
these
warnings
and
the
entire
user
manual
before
using
the
product:
Use
a
soft,
slightly
moistened
cloth.
Do
not
use
abrasive
or
corrosive
cleaning
agents,
as
these
may
cause
damage.
Use
luke
warm
water
and
mild
soap
to
clean
the
watch
and
chest
belt
thoroughly
after
each
training
session.
Never
use
the
products
in
hot
water
or
store
them
when
wet.
Do
not
bend
or
stretch
the
transmitter
part
of
the
chest
belt.
Do
not
subject
the
product
to
excessive
force,
shock,
dust,
temperature
changes,
or
humidity.
Never
expose
the
product
to
direct
sunlight
for
extended
periods.
Such
treatment
may
result
in
malfunction.
Do
not
tamper
with
the
internal
components.
Doing
so
will
terminate
the
product
warranty
and
may
cause
damage.
The
main
unit
contains
no
user
-serviceable parts.
Take
precautions
when
handling
all
battery
types.
Remove
the
batteries
whenever
you
are
planning
to
store
the
product
for
a
long
period
of
time.
When
replacing
batteries,
use
new
batteries
as
specified
in
this
user
manual.
The
product
is
a
precision
instrument.
Never
attempt
to
take
this
device
apart.
Contact
the
retailer
or
our
customer
service
department
if
the
product
requires
servicing.
Do
not
touch
the
exposed
electronic
circuitry,
as
there
is
a
danger
of
electric
shock.
Check
all
major
functions
if
the
device
has
not
been
used
for
a
long
time.
Maintain
regular
internal
testing
and
cleaning
of
your
device.
Have
your
watch
serviced
by
an
approved
service
center
annually.
When
disposing
of
this
product,
ensure
it
is
collected
separately
for
special
treatment
and
not
as
normal
household
waste.
Due
to
printing
limitations,
the
displays
shown
in
this
manual
may
differ
from
the
actual
display.
The
contents
of
this
manual
may
not
be
reproduced
without
the
permission
of
the
manufacturer.
am
The
technical
specifications
for
this
product
and
the
contents
of
the
user
manual
are
subject
to
change
without
notice.
ABOUT
OREGON
SCIENTIFIC
Visit
our
website
(www.oreaonscientific.com)
to
learn
more
about
Oregon
Scientific
products.
For
any
enquiry,
please
contact
our
Customer
Services
at
infofftregonscientific.corn.
EU-DECLARATION
OF
CONFORMITY
Hereby,
Oregon
Scientific,
declares
that
Bluetooth
Smart
Fabric
Chest
Belt
(model:
SZ999)
is
in
compliance
with
the
essential
requirements
and
other
relevant
provisions
of
Directive
1999/5/EC.
A
copy
of
the
signed
and
dated
Declaration
of
Conformity
is
available
on
request
via
our
Oregon
Scientific
Customer
Service.
CE
Cs)
RoHS
,COMPLIANT"
COUNTRIES
RTTE
APPROVED
COMPLIED
All
EU
countries,
Switzerland
FCC
/
IC
STATEMENT
This
device
complies
with
Part
15
of
the
FCC
Rules.
Operation
is
subject
to
the
following
two
conditions:
(1)
This
device
may
not
cause
harmful
interference,
and
(2)
This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
Changes
or
modifications
not
expressly
approved
by
the
party
responsible
for
compliance
could
void
the
user's
authority
to
operate
the
equipment.
This
equipment
has
been
tested
and
found
to
comply
with
the
limits
for
a
Class
B
digital
device,
pursuant
to
Part
15
of
the
FCC
Rules.
These
limits
are
designed
to
provide
reasonable
protection
against
harmful
interference
in
a
residential
installation.
This
equipment
generates,
uses
and
can
radiate
radio
frequency
energy
and,
if
not
installed
and
used
in
accordance
with
the
instructions,
may
cause
harmful
interference
to
radio
communications.
However,
there
is
no
guarantee
that
interference
will
not
occur
in
a
particular
installation.
If
this
equipment
does
cause
harmful
interference
to
radio
or
television
reception,
which
can
be
determined
by
turning
the
equjpment
off
and
on,
the
user
is
encouraged
to
try
to
correct
the
interference
by
one
or
more
of
the
following
measures:
Reorient
or
relocate
the
receiving
antenna.
Increase
the
separation
between
the
equipment
and
receiver.
Connect
the
equipment
into
an
outlet
on
a
circuit
different
from
that
to
which
the
receiver
is
connected.
Consult
the
dealer
or
an
experienced
radio
/
TV
technician
for
help.
DECLARATION
OF
CONFORMITY
The
following
Information
Is
not
to
be
used
as
contact
for
support
or
sales.
Please
visit
our
website
at
www.oregonscientffic.com
for
all
enquiries.
We
Name:
Address:
Telephone
No.:
Oregon
Scientific,
Inc.
19861
SW
95th
Ave.,Tualatin,
Oregon
97062
USA
1-800-853-8883
declare
that
the
product
Product
No.:
SZ999
Product
Name:
Bluetooth
Smart
Fabric
Chest
Belt
Manufacturer:
IDT
Technology
Limited
Address:
Block
C,
9/F,
Kaiser
Estate,
Phase
1,
41
Man
Yue
St.,
Hung
Horn,
Kowloon,
Hong
Kong
is
in
conformity
with
Part
15
of
the
FCC
Rules.
Operation
is
subject
to
the
following
two
conditions:
1)
This
device
may
not
cause
harmful
interference.
2)
This
device
must
accept
any
interference
received,
including
interference
that
may
cause
undesired
operation.
REPLACE
BATTERY
Please
replace
battery
promptly
as
it
may
affect
the
accuracy
of
the
readings.