Panamax M5400-PM Manual

Panamax M5400-PM Manual

Panamax M5400-PM manual content summary:

  • Panamax M5400-PM | Manual - Page 1
    -View services. The M5400-PM also provides surge protection for this line. One pair of RJ-11 telephone jacks is provided for this. The circuitry utilizes auto-resetting PTCRs and solidstate SIDACtors for reliability and unsurpassed protection. The clamping level of the M5400PM's telephone protector
  • Panamax M5400-PM | Manual - Page 2
    M5400-PM VOLTAGE REGULATOR Digital Voltmeter Digital LED voltmeter indicates the incoming line voltage. If line voltage drops below 90VAC, or if the line voltage exceeds 142VAC, the display will turn off and the "unsafe voltage" indicator will flash indicating an unsafe voltage condition. M5400-PM
  • Panamax M5400-PM | Manual - Page 3
    Amps Catastrophic Surge Circuit Yes Thermal Fusing Yes Over-voltage Shutoff 142 VAC ± 8 VAC Under-voltage Shutoff 90 VAC ± 2 VAC EMI/RFI Noise Filtration Banks 1, 2, 3, 4 80 db, 100 KHz - 2 MHz Bank 5 High Current Outlets 60 db, 100 KHz - 2 MHz Voltage Regulation (Banks 1-4) Power / Current
  • Panamax M5400-PM | Manual - Page 4
    provided, shall determine whether or not your request is eligible for payment. If the surge protector shows no signs of AC power or signal line surge damage and is working within design specifications, Panamax will return the unit to you with a letter explaining the test results and notifying
  • Panamax M5400-PM | Manual - Page 5
    BANK 1 BANK 2 BANK 3 BANK 4 BANK 5 VOLTAGE VOLTAGE VOLTAGE VOLTAGE HIGH WIRING REGULATION REGULATION REGULATION REGULATION CURRENT OK METER LIGHTS METER TOGGLE VOLTS IN VOLTS OUT M5400-PM VOLTAGE REGULATOR Principales características Regulación de voltaje Regula el voltaje de salida en
  • Panamax M5400-PM | Manual - Page 6
    maras y otros dispositivos. BANK 1 BANK 2 BANK 3 BANK 4 BANK 5 VOLTAGE VOLTAGE VOLTAGE VOLTAGE HIGH WIRING REGULATION REGULATION REGULATION REGULATION CURRENT OK METER LIGHTS METER TOGGLE VOLTS IN VOLTS OUT M5400-PM VOLTAGE REGULATOR Voltímetro digital El voltímetro digital LED indica el
  • Panamax M5400-PM | Manual - Page 7
    Especificaciones del M5400-PM Corriente alterna Voltaje de línea 120 V, 60 Hz Capacidad de corriente total 15 A Voltage Protection Rating (UL1449 3rd Edition, 3,000A):......... 500V Modos de protección L-N, L-G, N-G Nivel de fijación inicial 200 V Disipación de energía 2125 Joules Corriente de
  • Panamax M5400-PM | Manual - Page 8
    PM: $5,000,000 M5100-PM: $5,000,000 M5300-PM: $5,000,000 M5400-PM: $5,000,000 M4300-EX: $5,000,000 M5300-EX: $5,000,000 M5510-Pro: $5,000,000 M4310: $5,000,000 M5400-EX de daños a los equipos conectados. Antes de devolver el protector Panamax, el cliente deberá obtener un número de autorización de
  • Panamax M5400-PM | Manual - Page 9
    M5400-PM BANK 1 BANK 2 BANK 3 BANK 4 BANK 5 VOLTAGE VOLTAGE VOLTAGE VOLTAGE HIGH WIRING REGULATION REGULATION REGULATION REGULATION CURRENT OK METER LIGHTS METER TOGGLE VOLTS IN VOLTS OUT M5400-PM VOLTAGE REGULATOR MAX® 5400-PM par Panamax. 5 blocs prises isolés Le MAX 5400-PM ("LINE").
  • Panamax M5400-PM | Manual - Page 10
    et autres périphériques similaires. BANK 1 BANK 2 BANK 3 BANK 4 BANK 5 VOLTAGE VOLTAGE VOLTAGE VOLTAGE HIGH WIRING REGULATION REGULATION REGULATION REGULATION CURRENT OK METER LIGHTS METER TOGGLE VOLTS IN VOLTS OUT M5400-PM VOLTAGE REGULATOR Voltmètre numérique Voltmètre numérique à DEL
  • Panamax M5400-PM | Manual - Page 11
    Caractéristiques du M5400-PM Alimentation courant alternatif Line Tension en entrée 120V, 60Hz Intensité maximale totale 15 A Voltage Protection Rating (UL1449 3rd Edition, 3,000A):.........500V Modes de protection P-N, P-T, N-T Niveau de blocage initial 200V Dissipation d'énergie 2125 joules
  • Panamax M5400-PM | Manual - Page 12
    M4300-PM: $5,000,000 USD M5100-PM: $5,000,000 USD M5300-PM: $5,000,000 USD M5400-PM: $5,000,000 USD M4300-EX: $5,000,000 USD M5300-EX: $5,000 Service clientèle de Panamax à www.panamax.com/support** avant de renvoyer le système de protection à Panamax. Il vous faut à ce moment-là signaler à Panamax
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Key Features
Voltage Regulation
Regulates the output voltage on Banks 1-4 to
120 VAC ± 5 VAC. This is accomplished
through two boost stages and one buck stage
of voltage regulation. In Boost Stage 1 the
voltage is boosted in the 109-119V range,
while Boost Stage 2 boosts the voltage in the
100-109V range. The Buck Stage acts to
reduce voltage in the 125-136V range.
LiFT Technology EMI/RFI Noise Filtration :
Your audio/video components are constantly
being bombarded by electromagnetic interfer-
ence (EMI) and radio frequency interference
(RFI) through their AC power source. This
contaminated power can affect audio/video
equipment and will degrade the overall per-
formance of your entire system. Common
symptoms of contaminated power include
loss of picture detail, dull colors, pops, hiss-
es, hums and visual artifacts.
Automatic Over & Under Voltage Protection
(AVM):
Panamax's patent pending power monitoring
circuitry constantly monitors the AC line volt-
age for unsafe voltage conditions such as
momentary spikes or prolonged over-volt-
ages and under-voltages (brownouts). These
unsafe conditions pose a very dangerous
threat to all electronic equipment within the
home. If the MAX® 5400-PM senses an
unsafe power condition, it will automatically
disconnect your equipment from the power to
protect equipment from damage.Once the
voltage returns to a safe level, the M5400-PM
will automatically reconnect the power.
When subjected to a 6,000V (open circuit
voltage) / 500A (short circuit current) surge,
the M5400-PM limits its voltage output to
less than 330V peak, UL's best rating.
If the magnitude of the surge is greater than
the capacity of the surge protection compo-
nents, the M5400-PM's Protect or Disconnect
Circuitry will disconnect your equipment in
order to protect it. The M5400-PM will need
to be repaired or replaced by Panamax if this
occurs within the product’s 3 year warranty.
5 Isolated Outlet Banks
The M5400-PM is designed to provide noise
isolation between the outlet banks so that any
noise created by A/V components plugged
into the M5400-PM cannot contaminate the
power going to equipment plugged into the
other outlet banks of the M5400-PM.
Sequential Startup/Shutdown:
Complex audio/video systems may be sus-
ceptible to voltage transients generated inter-
nally at start-up/shutdown if all of the equip-
ment is powered on or off at the same time.
This can cause speaker “thumps” which are
not only annoying but can also damage the
speakers and/or trip product circuit breakers.
The M5400-PM is designed to eliminate these
transients by providing a “start-up” delay for
the High-Current outlets and a “shutdown”
delay for the Switched Outlet Banks. This
minimizes in-rush current issues by allowing
the components plugged into the Switched
Outlet Banks to power-up and stabilize before
any amplifiers and powered sub-woofers are
turned on. This sequence is reversed during
shutdown. The amplifiers and powered sub-
woofers turn off, their power supplies drain,
and then the equipment plugged into the
Switched Outlet Banks are turned off.
USB Charger:
The M5400-PM features a front panel con-
venience charger for mp3 players, cell
phones, video game controllers, and other
small electronics. NOTE: Some devices may
not be compatible with this USB charger.
Gaming LAN Port:
The M5400-PM features an easy-to-access
LAN port pass-thru from the rear panel to the
front panel. Perfect for online gaming.
Gaming Outlet:
The M5400-PM features a convenience outlet
located on the front panel.
Perfect for gaming
systems and other electronics. 120VAC ±
6VAC
Voltage Sense Trigger:
The M5400-PM volt-
age sense trigger input uses a standard
3.5mm (1/8") mini-mono plug.
This feature provides an ON/OFF trigger for
the M5400-PM using a Direct Current voltage
signal. Many components such as pre-ampli-
fiers and receivers have a DC trigger built in,
and will transmit a constant power signal
when turned on and in use. The presence of
this power signal will turn on the M5400-
PM's switched outlets. When the source com-
ponent is turned off, the voltage trigger signal
is also turned off and the M5400-PM's shut-
down sequence is initiated. An AC Adapter of
the appropriate voltage plugged into a
switched outlet may also be used if a DC trig-
ger is not built in.
Cable/Satellite/Antenna TV signal protec-
tion
Coaxial protection circuits achieve optimum
signal quality from our new coaxial protectors
that have the smallest signal loss on the mar-
ket - less than 0.5 db of attenuation from 0
MHz to 2.2 GHz. Our upgraded coaxial pro-
tection has been specifically designed to vir-
tually eliminate signal loss. The clamping
level of 75V will meet the demands of both
cable and satellite voltage while minimizing
exposure to damaging spikes and surges.
Telephone Line Protection:
Digital video recorders and satellite TV
receivers require a telephone line connection
for TV show scheduling and/or Pay-Per-View
services. The M5400-PM also provides surge
protection for this line. One pair of RJ-11 tele-
phone jacks is provided for this. The circuitry
utilizes auto-resetting PTCRs and solidstate
SIDACtors for reliability and unsurpassed
protection. The clamping level of the M5400-
PM's telephone protector is 260 volts. This
will allow typical ring voltage (90-130VAC)
and operating battery voltage (-48DC) to pass
through the circuit and still protect the
modem in your satellite receiver from dam-
age.
LAN Protection:
Protection circuits for 10/100 baseT Ethernet
lines. Incoming LAN line MUST be plugged
into the LINE jack. Patch cord to the equip-
ment MUST be plugged into the EQUIP jacks.
1 LAN jack goes to the front panel output jack.
8 wire protection, 52V clamping.
Model:
M5400-PM
INS00815-E
Rev. C
9/09
1
BANK 1
BANK 2
BANK 3
BANK 4
BANK 5
M5400-PM
VOLTAGE REGULATOR
METER LIGHTS
METER TOGGLE
VOLTAGE
REGULATION
VOLTAGE
REGULATION
VOLTAGE
REGULATION
VOLTAGE
REGULATION
HIGH
CURRENT
WIRING
OK
VOLTS IN
VOLTS OUT
CAUTION
– Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and electrical service panel.