    INSTALLATION INSTRUCTIONS MD2-TL MD2-TL 1. Turn off the equipment you are plugging into the MD2-TL. 2. Plug the surge protector into the wall outlet. A red "Line Fault" light indicates an improperly wired outlet that must be checked by a qualified electrician. 3. If the blue "Power On Protection
  • Panamax MD2 | Installation Instructions - Page 2
    surge protection capability, and under all of the circumstances failed to protect your connected equipment. MD2-TL Panamax AC protectors must be directly plugged into a properly grounded 3-wire AC outlet. Extension cords*, non-grounded two prong adapters, or other non-Panamax surge fees; service calls
  • 1
  • 2

Cover can be flipped around 180
degrees to hide LEDs from front
straight-on view if desired.
Cover can be removed and painted to match
color of wall. Do not paint the sides, top or
bottom. Warranty will be voided.
Cover of MD2-TL can easily be removed by
pulling cover at the 2 side indents (
1
).
Unit can be securely screwed into wall
outlet faceplate using either hole (
2
)
indicated (screw is included).
1
2
1690 Corporate Circle, Petaluma, CA 94954
800-472-55555
707-283-5900
• Fax 707-283-5901
• www.panamax.com
INSTALLATION INSTRUCTIONS MD2-TL
Bottom view of product
Top view
of product
INS00876-A
1/10
CUSTOMER SUPPORT:
800-472-5555
FEATURES
TEL / LAN
OUT TO
EQUIPMENT
LEFT SIDE
OUTLET
GROUND
PLUG OUT
RIGHT SIDE
OUTLET
GROUND
PLUG DOWN
Side views of product
1.
Turn off the equipment you are plugging into the MD2-TL.
2
.
Plug the surge protector into the wall outlet.
A red
"Line Fault"
light indicates
an improperly wired outlet that must be checked by a qualified electrician.
3.
If the blue
"Power On Protection OK"
light is on, plug your equipment into
the AC outlets on the surge protector.
4.
Connect incoming LAN or Telephone lines to the LAN /TEL IN connection.
The protection circuitry only works if connected properly.
The incoming line from
the wall outlet must be plugged into the “LAN /TEL IN” jack.
The telephone
equipment or modem must be plugged into the “LAN /TEL OUT” jack.
5.
Turn the connected equipment ON and check for power and correct operation.
Panamax surge protectors and the connected equipment must be indoors in a dry location and in the same building.
Do not install any
Panamax product near heat emitting appliances such as a radiator or heat register.
Do not install this product where excessive
moisture is present; for example, near a bathtub, sink, pool, basement floor, fish tank, etc.
It is not uncommon for a building to be improperly grounded.
In order to protect your equipment, and validate the warranty, Panamax
products must be plugged into a properly grounded 3-wire outlet.
Additionally, building wiring and grounding must conform to
applicable NEC (USA) or CEC (Canada) codes for the Panamax warranty to be valid.
Do not use 2-prong adapters with this product.
If an extension cord is required, use only Panamax #GEC1410.
If at any time your
surge protector indicates a Line Fault, call your electrician to correct the building wiring.
POWER ON /
PROTECTION OK- (blue)
normally ON - indicates
that the power is on,
surge protector is
functioning properly,
and all connected
equipment is protected.
LINE FAULT INDICATOR-
(red)
- If lit red, indicates
an improperly wired outlet.
AC outlets are turned 90 degrees from one
another to accommodate different style
plugs or transformers.
Properly Connecting Your Surge Protector
To completely protect your equipment from power surges, every wire leading into or out of the equipment you want to protect must be connected to the
appropriate Panamax surge protector.
Damaging lightning and power surges can get into your system through any AC power or signal line (phone lines,
grounding wires, coax cables, modem cables, etc.) connected to your electrical equipment.
The $100,000 Connected Equipment Protection Policy is invalid if any wire leading into or out of the equipment is not properly connected to the
appropriate Panamax surge protector(s).
The surge protector must also be plugged into a properly wired and grounded outlet.
Please see the warranty
for details or contact the Panamax Customer Relations department with questions.
Overview
Make sure you have the right surge protector to protect your electronic equipment.
Panamax makes protectors for almost every type of electronic
equipment.
Surge protectors that may look identical from the outside can be very different on the inside.
It is very important to use the surge protector
designed for your application. Two-outlet surge protectors are not designed for use with systems having more than two AC powered components.
Panamax offers a wide range of surge protectors designed for use with larger systems. If you have any questions about which product is best for your
applications, please see our web site www.panamax.com or contact Panamax Customer Relations at 800-472-5555
(7:30 a.m. – 4:30 p.m.
PST).
MD2-TL
TEL / LAN
IN
TEL / LAN
IN FROM
WALL
OPTIONS FOR SECURITY MOUNTING & FRONT COVER FACEPLATE
TEL / LAN
OUT
POWER ON
PROTECTION OK
LINE
FAULT
TYPICAL INSTALLATION
IMPORTANT SAFETY POINTS
Limited Lifetime Product
Warranty*
$
100,000
Limited Connected
Equipment Protection Policy*
*See documentation on back side for details.
PROPERLY GROUNDED
AC OUTLET
TEL
LINE
TEL OR LAN
WALL
OUTLET
MD2-TL
TEL
LINE
AC LINE