Panasonic AWRP400 AWPH400 User Guide

Panasonic AWRP400 - PAN TILT CTL Manual

Panasonic AWRP400 manual content summary:

  • Panasonic AWRP400 | AWPH400 User Guide - Page 1
    AW-RL400 AW-RC400 AW-RP400 AW-PH400 AW-PH400P Indoor Pan/Tilt Head AW-RP400N Pan/Tilt Control Panel AW-RC400N Cable Compensation Unit Roll Unit AW-RL400G AW-PH400 AW-RP400 AW-RC400 AW-RL400 Before attempting to connect, operate or adjust this product, please read these instructions
  • Panasonic AWRP400 | AWPH400 User Guide - Page 2
    (service) instructions in the literature accompanying the appliance. For CANADA This class A digital and used in accordance with the instruction manual, may cause harmful interference to SHOCK OR FIRE HAZARD DUE TO OVERHEATING. Models AW-RP400, AW-RC400 only Note: The rating plate (serial number
  • Panasonic AWRP400 | AWPH400 User Guide - Page 3
    and the point where they exit from the apparatus. 4) Follow all instructions. 5) Do not use this apparatus near water. 6) Clean only with when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way
  • Panasonic AWRP400 | AWPH400 User Guide - Page 4
    16 $ Mounting the camera 17 $ Attaching the wire 18 Replacing the consumable parts 19 Specifications 20 AW-RC400 Cable Compensation Unit 38 Introduction 38 Accessories 38 Parts and their function 39 How to mount the AW-RC400 in a rack 41 Specifications 42 AW-RP400 Pan/Tilt Control Panel
  • Panasonic AWRP400 | AWPH400 User Guide - Page 5
    Operating precautions ≥ Handle the units carefully. Dropping the units or subjecting them to strong impact may give rise to malfunctioning or accidents. ≥ Turn off the power before connecting or disconnecting the cables. Be absolutely sure to turn off the power before connecting or disconnecting the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 6
    from the AW-RP301, AW-RP305, AW-RP501, AW-RP505, AW-RP605 or AW-RP605A controller. ≥ In order to protect the environment when the pan/tilt head is to be discarded at the end of its service life, ask a specialized contractor to dispose of it properly. Accessories Rotary arm ...1 Camera mounting base
  • Panasonic AWRP400 | AWPH400 User Guide - Page 7
    Installation precautions Indoor Pan/Tilt Head AW-PH400 ≥ Do not install the unit on any of its sides. ≥ Avoid using the unit in the kitchen and other locations with lots of steam and oily vapors. ≥ Mount the camera on the pan/tilt head only when you have finished installing it. ≥ The maximum
  • Panasonic AWRP400 | AWPH400 User Guide - Page 8
    Indoor Pan/Tilt Head AW-PH400 Parts and their function 1 2 5 3 4 : ; < = > ? 8 6 7 8 9
  • Panasonic AWRP400 | AWPH400 User Guide - Page 9
    Rotary head connector panel J Indoor Pan/Tilt Head AW-PH400 K L M N O P Pedestal connector panel AW-PH400 1 Rotary head This rotates in the horizontal direction This rotates in the vertical direction. 9 Camera mounting base Mount the convertible camera on this base. : Pan/tilt head mounting
  • Panasonic AWRP400 | AWPH400 User Guide - Page 10
    to connect this to the SDI OUT connector on the AW-PB504 SDI card or other card installed in the convertible camera. A LENS I/F (2) connector [LENS I/F (2)] This signals of the camera and pan/tilt head. It is connected to the CONTROL OUT TO PAN/TILT connector on the AW-RP400 pan/tilt control panel
  • Panasonic AWRP400 | AWPH400 User Guide - Page 11
    BNC coaxial cable for the connecting cable. The AW-PB302 RGB card must be installed if the AW-E300, AW-E300A, AW-E600, AW-E800 or AW-E800A convertible camera is to be used. K 1394 connector [1394] This is used for the control of the convertible camera and pan/tilt head equipped with an IEEE1394 card
  • Panasonic AWRP400 | AWPH400 User Guide - Page 12
    Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) the arm is installed. For a stand-alone installation Rotary head Camera mounting base Rotary arm For installation on the ceiling Change the guide pin and screw positions as shown in the figure below on
  • Panasonic AWRP400 | AWPH400 User Guide - Page 13
    Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) 3 Mounting the tally lamp Connect the cable connector which is taped to the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 14
    Indoor Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Setting the mounting direction switch Set the switch as follows when the unit
  • Panasonic AWRP400 | AWPH400 User Guide - Page 15
    Pan/Tilt Head AW-PH400 Installation (Be sure to ask your dealer to install the The switches are set to support analog/SDI at the factory.) ≥ Analog/SDI support IP/IEEE switch: IEEE 422/IP switch: 422 ≥ Web card support IP/IEEE switch: IP 422/IP switch: IP ≥ IEEE1394 card support IP/IEEE switch: IEEE
  • Panasonic AWRP400 | AWPH400 User Guide - Page 16
    AW-PH400 Installation (Be sure to ask your dealer to install the unit.) $ Installing the pan/tilt head When installing the pan/tilt head, follow the instructions /tilt head has been installed, mount the camera on it. ≥ When installing the pan/tilt manually. Doing so may result in malfunctioning. 16
  • Panasonic AWRP400 | AWPH400 User Guide - Page 17
    . (Before mounting a large lens, consult with your dealer.) 2 Insert the rubber piece between the camera and pan/tilt head, and mount the convertible camera after aligning it with the guide pins. Use a tool to tighten up the mounting screws so that they are securely tightened. For a stand-alone
  • Panasonic AWRP400 | AWPH400 User Guide - Page 18
    the wire The wire is not provided. Use one which is strong enough to bear the weight of the whole camera (camera + lens). When mounting the cameras with fan (AW-E655, AW-E750, AW-E800, AW-E800A) 1 Use the wire mounting screw (M4!8 mm with flat washer and spring washer) to attach one end of the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 19
    consumable parts Indoor Pan/Tilt Head AW-PH400 $ Replacing the battery The battery has a service life of approximately 5 years. The the power is turned off, but if the internal battery has reached the end of its service life, the data will be lost when the power is turned off. Replace a battery
  • Panasonic AWRP400 | AWPH400 User Guide - Page 20
    ) The tilt range is limited to 190 degrees by the initial setting of the AW-RP400. To move beyond 190 degrees, change the AW-RP400 setting. The tilt range is subject to restrictions depending on the cable and lens of camera to be mounted on pan/tilt head. Pan range: 400 degrees (approx. ±200 degrees
  • Panasonic AWRP400 | AWPH400 User Guide - Page 21
    MEMO 21 AW-PH400
  • Panasonic AWRP400 | AWPH400 User Guide - Page 22
    Pan/Tilt Control Panel AW-RP400 Introduction ≥ This pan/tilt control panel enables up to five AW-PH400 indoor pan/tilt heads to be controlled. ≥ By connecting the AW-CB400 remote operation panel or WV-CB700A remote control box to the control panel, the convertible cameras mounted on the pan/tilt
  • Panasonic AWRP400 | AWPH400 User Guide - Page 23
    /tilt heads to the cameras is turned off. NOTE ≥ The centering of the joystick and zoom switch is adjusted when the OPERATE switch has been set to [ON]. Therefore, do not touch the joystick or zoom switch while this switch is at the [ON] position. ≥ When an additional AW-RP400 control panel is
  • Panasonic AWRP400 | AWPH400 User Guide - Page 24
    Tilt Control Panel AW-RP400 Parts and their function 7 IRIS [AUTO/MANU/LOCK] button Use this to select the method for adjusting the lens iris of the cameras in the button lamp is off. LOCK: The lens iris is locked at the manually adjusted setting. It does not move even when the (9) IRIS dial
  • Panasonic AWRP400 | AWPH400 User Guide - Page 25
    this control panel is connected to the MONI SEL IN connector on the AW-RC400 cable compensation unit, the images of the camera connected to the MONI1 or MONI2 connector on the AW-RC400 can be output. ≥ When two AW-RP400 control panels are connected, the combination of the control panels which select
  • Panasonic AWRP400 | AWPH400 User Guide - Page 26
    panels using a 10BASE-T (equivalent to UTP category 5) straight cable. Master control panel AW-RP400 Slave control panel AW-RP400 EXT CONT IN EXT CONT IN EXT CONT OUT 10BASE-T 10BASE-T straight cable EXT CONT OUT N CAMERA CONTROL IN FROM RCB [P1] to [P5] connectors Connect the WV-CB700A
  • Panasonic AWRP400 | AWPH400 User Guide - Page 27
    of the system selected by the master AW-RP400 from the MONITOR1 connector on the AW-RC400 and the images of the system selected by the slave AW-RP400 from the MONITOR2 connector on the AW-RC400. T CAMERA CONTROL IN FROM ROP connector Connect the AW-CB400 remote operation panel to this connector
  • Panasonic AWRP400 | AWPH400 User Guide - Page 28
    Pan/Tilt Control Panel AW-RP400 Menu settings $ Operation method 1 The menu setting items are displayed when the MENU/LIMIT switch is held down for two or more seconds. AW-RP400 P/T CONTROL PANEL ; PRIORITY ; DIRECTION SET ; DIRECTION PAN NORMAL ; DIRECTION TILT NORMAL ; DIRECTION
  • Panasonic AWRP400 | AWPH400 User Guide - Page 29
    , UN-INTERLOCK OFF, ON 1 to 50 1 to 50 1s to 30s STOP, RUN STORE, LOAD INTERLOCK ON 1 50 1s STOP - - - PRIORITY (MASTER/SLAVE) When two AW-RP400 pan/tilt control panels have been connected, the priority of the CONTROL SELECT buttons is to be set. When MASTER is selected as the setting
  • Panasonic AWRP400 | AWPH400 User Guide - Page 30
    to the preset positions; conversely, the lower the setting, the slower the movement speed. IRIS CONTROL setting (BOTH/RP400/CB400) When the AW-CB400 remote operation panel has been connected to the AW-RP400 control panel, this menu item is used to set which control panel is to be used to adjust the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 31
    Menu settings Pan/Tilt Control Panel AW-RP400 OPTION SWITCH A to H settings (NOT USE / DEF / WIP / HEATER/FAN / LAMP / OPTION / ND / EXT / AF) The following functions can be allocated to OPTION buttons A to H.
  • Panasonic AWRP400 | AWPH400 User Guide - Page 32
    : A different pan/tilt head and camera system can be selected by the AW-RP400 and AW-CB400. ≥ When two AW-RP400 units are connected, INTERLOCK is always to this unit only, and refrain from using it with a personal computer, digital camera or other device. ≥ Do not eject the SD memory card, turn off
  • Panasonic AWRP400 | AWPH400 User Guide - Page 33
    rack (which accommodates units totaling 420 mm in width), provide panels or other parts to supplement the AW-RP400's width so that it will fill the rack width-wise. ≥ If the AW-RP400 is joined to the AW-CB400, the resulting width will be equivalent to that of the full width of the rack (which
  • Panasonic AWRP400 | AWPH400 User Guide - Page 34
    Pan/Tilt Control Panel AW-RP400 How to change the position of the connector panel The position of the connector panel can be changed from the rear panel to the bottom
  • Panasonic AWRP400 | AWPH400 User Guide - Page 35
    ❈ Before replacing the zoom switch, turn off the power. 1 Remove the four screws that secure the zoom lever. Screws! 4 Pan/Tilt Control Panel AW-RP400 2 Pull out the zoom lever, disconnect the two cables from the circuit board inside, and remove the zoom lever. 3 Plug the two cables extending
  • Panasonic AWRP400 | AWPH400 User Guide - Page 36
    Pan/Tilt Control Panel AW-RP400 Replacing the consumable parts The joysticks and zoom switch are consumables. Replace them if they are not working properly. Ask your dealer to do the replacement work. 36
  • Panasonic AWRP400 | AWPH400 User Guide - Page 37
    (UTP category 5), max. 500 meters RJ45, monitor switching signal output; 10BASE-T straight cable (UTP category 5), max. 50 meters RJ45, additional AW-RP400 control signal output; 10BASE-T straight cable (UTP category 5), max. 500 meters Input/output connectors INCOM (top panel): TALLY/INCOM: XLR
  • Panasonic AWRP400 | AWPH400 User Guide - Page 38
    a 5µs advance function for the sync signals in order to provide easy support for a system (another cable compensation unit is required) in which the coaxial cable connected between this AW-RC400 cable compensation unit and the camera is longer than 500 meters. NOTE ≥ Input either sync signals to
  • Panasonic AWRP400 | AWPH400 User Guide - Page 39
    (equivalent to UTP category 5). It is then possible to output the video signals of the camera selected by the AW-RP400 or the AW-CB400 remote operation panel which is connected to the AW-RP400, to the MONITOR1 or MONITOR2 connector. 9 G/L IN connectors The sync signals (black burst signals) are
  • Panasonic AWRP400 | AWPH400 User Guide - Page 40
    the cameras selected by the AW-RP400 pan/tilt control panel or the AW-CB400 remote operation panel which is connected to the AW-RP400 are output the storage space cover. Stow the AW-PS301 AC adaptor in such a way that the pull-out cable will not be stressed. Trouble will occur in the AC adaptor if
  • Panasonic AWRP400 | AWPH400 User Guide - Page 41
    Cable Compensation Unit AW-RC400 How to mount the AW-RC400 in a rack Use the accessory rack-mounting adaptors and accessory mounting screws (M4!8 mm) to mount the unit in a the rack-mounting adaptors to the both ends of the unit, and fix it using four mounting screws. Mounting screws AW-RC400 41
  • Panasonic AWRP400 | AWPH400 User Guide - Page 42
    safety information. Input connectors DC 12V IN: G/L IN: VIDEO/Y, Pr/C, Pb: MONI SEL IN: For connecting optional accessory AC adaptor (AW-PS301) BNC!2, automatically terminated by 75-ohm resistance, loop-through output, black burst BNC!3 (5 sets), 75-ohm termination Composite Y/C Component
  • Panasonic AWRP400 | AWPH400 User Guide - Page 43
    Unit AW-RL400 NOTE ≥ Since the roll unit causes the camera to rotate, the user should ensure that all the wiring such as the camera cable and lens cable will not become entangled when the roll unit is operated. ≥ When the roll unit is to be discarded at the end of its service life
  • Panasonic AWRP400 | AWPH400 User Guide - Page 44
    Roll Unit AW-RL400 Parts and their function 1 2 5 3 4 6 1 Rotary ring 2 Camera mounting screw (U1/4"-20UNC) After mounting the camera, secure it firmly using this screw. 3 Camera mounting plate (A) (B) Mount the camera on this plate using the camera mounting screws. 4 Camera mounting plate
  • Panasonic AWRP400 | AWPH400 User Guide - Page 45
    pan/tilt head using the mounting screws (M5!22 mm, with flat washers, pan/tilt head accessory). Rotary arm Roll unit Camera mounting plate (consisting of 2 separate sub plates) AW-RL400 3 Loosen the two screws of camera mounting plate which is already installed to the roll unit. Then remove the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 46
    the steps below to mount the camera mounting sub plates, which were separated in step 4, onto the camera body. When the AW-E750, AW-E650 or AW-E350 is used as the camera (1) Remove the screw attached to camera mounting sub plate (A), and use it to mount camera mounting sub plate (B) onto the tripod
  • Panasonic AWRP400 | AWPH400 User Guide - Page 47
    mounting plate to the roll unit in a way contrary to the procedure of removing it in step 3. Roll Unit AW-RL400 AW-RL400 Camera mounting plate's screws 7 Using the pan/tilt head connecting cable provided, connect the [OPTION] connector on the pan/tilt head connector panel and the connector
  • Panasonic AWRP400 | AWPH400 User Guide - Page 48
    Roll Unit AW-RL400 Specifications Supply voltage: DC 24 V Power consumption: Approx. 24 W 1 indicates safety information. Pan/tilt head connector: Connected to pan/tilt head using cable supplied
  • Panasonic AWRP400 | AWPH400 User Guide - Page 49
    TO PAN/TILT HEAD (1 to 5) connectors on the AW-RP400. The maximum extension distance is 500 meters when using UTP category 5 cables or their equivalent. ≥ Use the camera cables supplied with the pan/tilt head to connect the AW-PH400 to the convertible camera. ≥ Connect the iris control cable of the
  • Panasonic AWRP400 | AWPH400 User Guide - Page 50
    Indoor Pan/Tilt Head Pan/tilt head/camera control signals Camera cable supplied with AW-PH400 Convertible camera Genlock signals Video signals AW-CB400 Remote Operation Panel AC power cable supplied with AW-PH400 AW-RP400 Pan/tilt control panel AW-RC400 Cable Compensation Unit Video signal
  • Panasonic AWRP400 | AWPH400 User Guide - Page 51
    Genlock signals MONITOR1 Monitor Monitor switching Pan/tilt head and camera control MONITOR2 Monitor Cable provided with AW-CB400 AW-PS301 AC adaptor AW-RC400 Cable Compensation Unit Headset AW-PS505 AC adaptor Headset Pan/Tilt Control Panel AW-RP400 Remote Operation Panel AW-CB400 51
  • Panasonic AWRP400 | AWPH400 User Guide - Page 52
    on the setting methods and related aspects, refer to "Setting the mounting direction switch" in the operating instructions for the AW-PH400. Now proceed with the settings for the AW-RP400 pan/tilt control panel. 1 Use the CONTROL SELECT buttons to select the pan/tilt head whose movement range
  • Panasonic AWRP400 | AWPH400 User Guide - Page 53
    [50] will light. $ Providing cable compensation for the cameras Make these adjustments using the AW-RC400 cable compensation unit. 1 Connect a waveform monitor to the video output connector on the AW-RC400, and set the signals supplied to the corresponding video
  • Panasonic AWRP400 | AWPH400 User Guide - Page 54
    balance, etc. of the cameras. For details on the camera adjustments, refer to the operating instructions of the AW-CB400 remote operation panel or WV-CB700A remote control box. $ Tracing memory settings Perform these settings on the AW-RP400 pan/tilt control panel. The AW-RP400 comes with a tracing
  • Panasonic AWRP400 | AWPH400 User Guide - Page 55
    the data is to be registered. Only the lamp of the button pressed now lights, and START button flashes. The pan/tilt head position and camera settings prevailing at this time are recorded as the start position of the tracing memory. ≥ When the STOP button is now operated, the registration of
  • Panasonic AWRP400 | AWPH400 User Guide - Page 56
    data Perform these settings on the AW-RP400 pan/tilt control panel. The AW-RP400 comes with a preset memory function for cameras. ≥ Decide on the view angle and focus using the PAN, TILT, ZOOM and FOCUS controls. ≥ Select auto iris or manual iris using the IRIS [AUTO/MANUAL/LOCK] button. ≥ If manual
  • Panasonic AWRP400 | AWPH400 User Guide - Page 57
    Operating procedures Playing the preset memory data 1 Select the pan/tilt head system using one of the CONTROL SELECT buttons. 2 When the button corresponding to the registered preset memory data is pressed, the pan/tilt head system is set to the registered status. 57
  • Panasonic AWRP400 | AWPH400 User Guide - Page 58
    Hirose Electric ❈ The cable lengths are approximate. Ensure that their lengths are appropriate for the actual system used. Connect to the IRIS connector on the camera. Cable length: At least 420 mm or so
  • Panasonic AWRP400 | AWPH400 User Guide - Page 59
    Cable specifications 59 When an IASD, WASD or VASD lens (digital drive) made by Canon is used Connector: 10136-3000VE made by Sumitomo 3M Case: 10336-52F0 their lengths are appropriate for the actual system used. Connect to the IRIS connector on the camera. Cable length: At least 420 mm or so
  • Panasonic AWRP400 | AWPH400 User Guide - Page 60
    Hirose Electric ❈ The cable lengths are approximate. Ensure that their lengths are appropriate for the actual system used. Connect to the IRIS connector on the camera. Cable length: At least 420 mm or so
  • Panasonic AWRP400 | AWPH400 User Guide - Page 61
  • Panasonic AWRP400 | AWPH400 User Guide - Page 62
  • Panasonic AWRP400 | AWPH400 User Guide - Page 63
  • Panasonic AWRP400 | AWPH400 User Guide - Page 64
    . Fax (800) 334-4880 Emergency after hour parts orders (800) 334-4881 TECHNICAL SUPPORT: Emergency 24 Hour Service (800) 222-0741 Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario L4W 2T3 (905) 624-5010 Panasonic de Mexico S.A. de C.V. Av angel Urraza Num. 1209 Col. de Valle 03100 Mexico
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Before attempting to connect, operate or adjust this product,
please read these instructions completely.
AW-PH400
AW-RP400
AW-RC400
AW-RL400
AW-PH400
AW-RC400
AW-RP400
AW-RL400
Before attempting to connect, operate or adjust this product,
please read these instructions completely.
Indoor Pan/Tilt Head
AW-PH400P
Pan/Tilt Control Panel
AW-RP400N
Cable Compensation Unit
AW-RC400N
Roll Unit
AW-RL400G