- Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 1
APPENDIX A INSTALLATION INSTRUCTIONS CU-3KS19NBU CU-4KS24NBU CU-4KS31NBU (852-6-4190-581-00-1) A-1 - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 2
service port R410A: 5/16" Contents Page IMPORTANT! Please Read Before Starting 2 Model Combinations Combine indoor and outdoor units only as listed below. Model No. Indoor Unit CS-MKS7NKU CS-MKS9NKU CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU CS-MKS9NB4U CS-MKS12NB4U CS 5. WIRING INSTRUCTIONS 22 5-1. - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 3
are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions. In Case of Improper Installation The manufacturer shall in no way be responsible for improper - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 4
OHDQXSWKHVLWHDIWHU\RXILQLVKUHPHPEHULQJWRFKHFN that no metal scraps or bits of wiring have been left inside the unit being serviced. Others CAUTION 9HQWLODWHDQ\HQFORVHGDUHDVZKHQLQVWDOOLQJRUWHVWLQJ the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 5
before beginning. If the electric wiring diagram does not appear in this manual, please check for the diagram on the indoor unit. 1-1. Tools specified instructions or limitations. Table 2 Model CS-MKS7NKU, CS-MKS9NKU, CS-MKS12NKU CS-MKS18NKU CS-MKS24NKU CS-MKS9NB4U, CS-MKS12NB4U CS-KS18NB4UW - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 6
2. Installation Site Selection 2-1. Indoor Unit WARNING To prevent abnormal heat generation and the possibility of fire, do not place obstacles, enclosures and grilles in front of or surrounding the air conditioner in a way that may block air flow. AVOID: direct sunlight. nearby heat - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 7
.), charge additional refrigerant (R410A) by 0.22 oz./ft. No additional charge of compressor oil is necessary. For more detailed charging information, refer to the Technical & Service Manual. 6 - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 8
52mm) 3/8"(9.52mm) Indoor unit (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) Fig. 4c 7 - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 9
) 3/8"(9.52mm) 3/8"(9.52mm) 3/8"(9.52mm) Indoor unit (CS-MKS18NKU) (CS-KS18NB4UW) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) Fig. 4d (C) (1/2"(12.70mm - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 10
1/4"(6.35mm) 3/8"(9.52mm) 1/4"(6.35mm) Indoor unit (CS-MKS18NKU) (CS-KS18NB4UW) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) Fig. 4h (C) Outdoor unit - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 11
35mm) 3/8"(9.52mm) 1/4"(6.35mm) 3/8"(9.52mm) 1/4"(6.35mm) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) (CS-MKS7NKU,CS-MKS9NKU,CS-MKS12NKU) (CS-MKS9NB4U,CS-MKS12NB4U) Flare 1/2"(12.70mm) Union 3/8"(9.52mm) (1/2"(12 - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 12
so that sufficient space is ensured for maintenance to be carried out without trouble. In general the top also must be unobstructed. (Fig. 5b) ground level to reduce humidity and protect the unit against possible water damage and decreased service life. (Figs. 5c and 5d) Fig. 5a Min. Min. 7' (2 m) - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 13
(1) Recommended dimensions of the baffle plates Air Intake Baffle O H A 2- 15/64" (2- 6 mm) C E D F 3- 1/4" (3- 6.5 mm) J R L Q I K Air Discharge Baffle I B J H C K 4- 1/4" G (4- 6.5 mm) AE G F B G Fig. 5g D Fig. 5h For Air Intake Dimensions A B C D E F G Model CU- - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 14
(3) Installation procedure 1. Air Intake Baffle (1) Left side 1. Remove the top panel from the unit. 2. Remove the panel side L, and drill 3 holes of ø1/4 inch (6.5 mm) at the prescribed position. 3. Install the windbaffle on the unit using field supply bolts and nuts. 4. Recommended bolts to be - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 15
(2) CU-4KS24NBU 23-15/16 5-11/32 15/32 A Fig. 6a 1-13/16 2-1/16 2-1/32 4-1/2 A 35-7/16 (900) 2-29/32 Service valve on wide tube side (Outer diameter 1/2"(12.70)) Service valve on narrow tube side (Outer diameter 1/4"(6.35)) 12-19/32 13-19/32 14-17/32 2-3/4 2-3/4 29-1/8 (740) 2-15/16 - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 16
Over 4"(10cm) Ensure 6"(15cm) of space if a drain hose is to be used. Over 1'8"(50cm) Over 8"(20cm) Power breaker D C B A Indoor unit A Service space Over 10"(25cm) Access panel C Base (not provided) (concrete or similar material) Fasten with anchor bolts (not provided) (3/8" or M10, 4 locations - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 17
3. Installation Process 3-1. Embedding the Tubing and Wiring Do not connect tubes to locations that are embedded. Be sure to bind refrigerant tubing and inter-unit cables together with vinyl tape. The power cable must be obtained on-site. (#12: Less than 85 ft.) # ... AWG (American Wire Gauge) - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 18
. 430 - 480 lbs·in (490 - 550 kgf·cm) Approx. 590 - 710 lbs·in (680 - 820 kgf·cm) Union Flare nut Fig. 13 Service valve on D narrow tube side C B A Service valve on wide tube side Fig. 14 17 Apply the provided labels to the indoor and outdoor unit tubing connectors to prevent errors - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 19
CAUTION Be sure to match refrigerant tubing and electric wiring between indoor and outdoor units. Torque wrench Indoor unit Spanner 3-6. Insulation of Refrigerant Tubing I M P O R TA N T To prevent heat loss and wet floors due to dripping of condensation, both tubes must be well insulated with a - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 20
as indicated below. Therefore, they must be purged completely. pressure in the system rises operating current rises cooling efficiency drops Service valve on narrow tube side Service valve on wide tube side moisture in the air may freeze and block capillary tubing water may lead to - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 21
pump adapter, read the vacuum pump adapter manual, and use the adapter correctly. NOTE External diameter of service port R410A: 5/16" Fig. 21 spindle, an extremely small amount of refrigerant may leak. This does not indicate a problem. Use a hex wrench of a type to which force can be easily - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 22
is running, apply liquid soap to check for any gas leaks around the service valves or caps. (14) If there is no leakage, stop the air to protect the indoor unit heat exchanger from freezing and does not indicate a problem. Cap (4) Disconnect the manifold gauge and the inter-unit tubes, and attach - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 23
5. Wiring Instructions 5-1. General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 24
WARNING Be sure to comply with local codes on running the wire from the indoor unit to the outdoor unit (size of wire and wiring method, etc.). Each wire must be firmly connected. No wire should be allowed to touch refrigerant tubing, the compressor, or any moving part. Be sure to connect - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 25
hazard may also exist. Therefore, be sure all wiring is tightly connected. When connecting each power wire to the corresponding terminal, follow the instructions "How to connect wiring to the terminal" and fasten the wire securely tight with the fixing screw of the terminal plate. How to connect - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 26
5-5. Wiring Instructions for the Outdoor Unit CAUTION Be sure to correctly align inter-unit cables A, B, C and D. Outdoor unit Terminal board 1 2 Indoor unit A A is the indoor unit with refrigerant tubing that is connected to service valve 1 2 3 A (bottom) of the outdoor unit. Terminal board - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 27
the unit according to your local codes. 6. Test Run Performing a test run Refer to the test run procedures in the indoor unit installation manual. Perform the test run separately for each connected indoor unit. If 2 units are operated simultaneously, it is not possible to correctly check for - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 28
terminal. 8. Installation Check Sheet The strength of the installation location is sufficient to support the air conditioner weight. The indoor and outdoor units are installed level and in the wall. All service valves are fully open. Remote controller signals are being positively received. - Panasonic CU-3KS19NBU | CU-3KS19NBU/CU-4KS24NBU/CU-4KS31NBU - Installation Manua - Page 29