Panasonic EYFST100NM Owner s Manual

Panasonic EYFST100NM Manual

Panasonic EYFST100NM manual content summary:

  • Panasonic EYFST100NM | Owner s Manual - Page 1
    Panasonic
  • Panasonic EYFST100NM | Owner s Manual - Page 2
    Table Of Contents • Transducer Warning, Basic Instructions & Mounting... Page 3 • Transducer Overview Page 4 • Joint Simulator Overview Page 5 • Joint Simulator Setup for Continuous Drive Tools.......Page 6 • Joint Simulator Setup for Discontinuous Drive Tools ..Page 7 •
  • Panasonic EYFST100NM | Owner s Manual - Page 3
    Panasonic Static Transducers • Warning & Basic Instructions - Panasonic static transducers are designed for testing mechanical pulse tools, click wrenches, beam, clutch, stall, pulse, current controlled and transducerized (DC) tools. When using a shut-
  • Panasonic EYFST100NM | Owner s Manual - Page 4
    Panasonic Static Transducers EYFST22NM • Models - EYFST22NM - 22 Nm 3/8" Sq. Drive Static Transducer EYFST100NM • Working Range - 2-22 Nm • 3/8" Joint Simulator - EYFST100NM - 100 Nm 1/2" Sq. Drive Static Transducer • Working Range - 15-100 Nm • 1/2" Joint Simulator • Input Voltage - USB
  • Panasonic EYFST100NM | Owner s Manual - Page 5
    Panasonic Joint Simulators • Models - EYFJS22NM - 3/8" Joint Simulator • 3/8" Square Drive • 22 Nm (16 Ft. Lbs.) Max Torque EYFJS22NM • 4 Sets of Washers (Qty. 4 Washers/Set) - Each set is for a specific torque range. EYFJS100NM - Laser marked for differentiating between sizes - EYFJS100NM
  • Panasonic EYFST100NM | Owner s Manual - Page 6
    3/8" Joint Simulator - Clutch Tools Spacer Cup Washers (Compression Washer) Each washer will be laser engraved for identification. Base It's imperative to make sure that the gearing structure lines up correct before each rundown! Metric Grade 10.9 Bolt Lubrication is needed under the head for
  • Panasonic EYFST100NM | Owner s Manual - Page 7
    It's imperative to make sure that the gearing structure lines up correct before each rundown! Spacer Cup Washers (Compression Washer) Each washer will be laser engraved for identification. Threads Lubrication is needed for joint consistence. Base 3/8" & 1/2" Joint Simulator - Mechanical Pulse Tools
  • Panasonic EYFST100NM | Owner s Manual - Page 8
    Panasonic 3/8" Joint Simulator Comparison Competitive Belleville Washer Type Panasonic's Cup Washer Type Rundown Adapter Static Transducer Limited sizes of rundown adaptors with one size of Belleville Washers limits the working torque range. Qty.16 Belleville Washers Many moving parts and each
  • Panasonic EYFST100NM | Owner s Manual - Page 9
    through the installation process automatically 5. Installation Complete, Click "OK" 6. Finished, Click "Close" To obtain a copy of the software, please find the link in the owners manual or visit our website at www.panasonic.com/assemblytools
  • Panasonic EYFST100NM | Owner s Manual - Page 10
    Connecting The Transducer To The PC Connect Sensor Disconnect Sensor Sensor Settings Connected Transducer Screen Shot Start "Panasonic Torque Analyzer" Software Click the "Sensor Settings" Button or Navigate to File/Settings Sensor Settings Screen Shot USB Port Dropdown Select the connected
  • Panasonic EYFST100NM | Owner s Manual - Page 11
    /Stop Recording Save/Load/ Export Graph Graph The graph will automatically update and zero at the beginning of each rundown (Default to Auto Zero) Zero Manually zero out the transducer. Reset Manually reset the graph and readings.
  • Panasonic EYFST100NM | Owner s Manual - Page 12
    Torque Analyzer Software - Results Screen Results Recorded Data/Rundowns Units Record/ Stop Recording Export Data Create Statistical Report Tool #/Tool Name/Comments How To Delete A Result Select the row to be deleted by left clicking on the row then right click (while still over the
  • Panasonic EYFST100NM | Owner s Manual - Page 13
    Parameter Tab - View/Edit Settings Parameter Control Mode (View/Edit general parameter settings) 1. Editable Fields a. Trigger Level b. Trigger Delay c. Trigger Mode d. Control Win 1 Min e. Control Win 1 Max f. Control Win 2 Min g. Control Win 2 Max h. LED Mode 2. Non Editable Fields a. Target Win
  • Panasonic EYFST100NM | Owner s Manual - Page 14
    Trigger Level Torque to start recording graph (Set to approx. 10-20% Target) Trigger Delay Leave at 0.1 Trigger Mode Determines which direction the transducer will read the torque applied Parameter Tab/Control Mode - View/Edit Settings Control Window 2 Secondary Window for Target torque Tolerance
  • Panasonic EYFST100NM | Owner s Manual - Page 15
    Parameter Tab/Communication Interface - View/Edit Settings Graph Output Data Rate This is the number of points recorded to the graph. 500 samples/s is good
  • Panasonic EYFST100NM | Owner s Manual - Page 16
    Parameter Tab/Signal Conditioning - View/Edit Settings Low Pass Filter 100,200,300,400,500, No Filter. This directly affects the height of the torque. (We recommend 500 for continuous and discontinuous drive tools.) 50/60Hz Rejection No filter - This is for filtering externally powered transducers (
  • Panasonic EYFST100NM | Owner s Manual - Page 17
    Understanding Frequency/Hz Filters Torque Actual Value Output Value At 500 Hz Time The "Pulse Tool Compensation" setting is used to align the transducers output torque reading (Peak Value) and static audit. Increasing the "Pulse Tool Compensation" setting increase the transducers "Peak Value" and
  • Panasonic EYFST100NM | Owner s Manual - Page 18
    Setup For Testing Continuous Drive Tools Joint Simulator Panasonic Torque Analyzer Software Static Transducer Windows PC USB Cable Washer Sets
  • Panasonic EYFST100NM | Owner s Manual - Page 19
    Setup for Continuous Tools (Clutch Tool) Start Software Select Parameters/ Signal Conditioning Select Graph Tab Click Record Graph Connect Transducer Set "Low Pass Filter" to 500 Hz Start Testing Tool Select Joint Simulator (see chart) Click "Parameters" Select Parameters/Control Mode and
  • Panasonic EYFST100NM | Owner s Manual - Page 20
    Setup For Testing Discontinuous Drive Tools Joint Simulator Panasonic Torque Analyzer Software Audit Wrench Static Transducer Windows PC USB Cable Washer Sets
  • Panasonic EYFST100NM | Owner s Manual - Page 21
    Setup for Discontinuous Tools (Mechanical Pulse Tool) Start Software Connect Transducer Select Parameters/ Signal Conditioning Select Graph Tab Click Record Graph Set "Low Pass Filter" to 500 Hz Conduct One Rundown Select Joint Simulator (see chart) Click "Parameters" Select Parameters/
  • Panasonic EYFST100NM | Owner s Manual - Page 22
    Validation Worksheet/CMK Statistics Machine Capability Study Date/Time: Sensor Serial Number: Tool Type: Tool / Part No.: Tool / Part Name: Batch: Comment: Target Value [Nm]: Tolerance (+/-): +Tolerance [Nm]: -Tolerance [Nm]: Upper Limit [Nm]: Lower Limit [Nm]: 2015-01-07 21:36 M1B4EF7 EYFST20NM
  • Panasonic EYFST100NM | Owner s Manual - Page 23
    Create a Capability Report Once the transducer is setup, conduct "X" number of rundowns Click on the "Results" tab Enter Tool Model # & Name (Serial #) Click the "Excel" button (Export Results) Click the "..." to browse to the "export statistic.xls" Select "export statistic.xls" Click "Open"
  • Panasonic EYFST100NM | Owner s Manual - Page 24
    Update Transducer Firmware Startup Panasonic Torque Analyzer Software Connect USB cable to the transducer Click the "Connect" button in the software Click in the top menu "Extras" Select "Sensor Firmware Upgrade" A window will appear like the one to the left Remove USB cable from transducer (
  • Panasonic EYFST100NM | Owner s Manual - Page 25
    Transducer Factory Defaults Parameter 1. Control Mode a. Trigger Level - 0 b. Trigger Delay - 0.1 c. Trigger Mode - Trigger on pos. values d. Control Win 1 Min - 0 e. Control Win 1 Max - 22 or 100 f. Control Win 2 Min - 0 g. Control Win 2 Max - 22 or 100 h. LED Mode - Trigger Condition 2.
  • Panasonic EYFST100NM | Owner s Manual - Page 26
    Best Practices - New Installation Of Discontinuous Drive Tools Following these guidelines, including the "Setup Worksheet", can streamline setup and the verification process. Torque Curves Determine Tool For Application Setup Tool on Application Obtain Application Specifications Method For New
  • Panasonic EYFST100NM | Owner s Manual - Page 27
    Best Practices - Reinstating Discontinuous Drive Tools Setup Tool Verify Tool In Calibration Lab Setup Worksheet Look Up Application Settings On Worksheet Method For Reinstating Tools Run Tool On Application Update Worksheet Setup Worksheet Verify Tool On Application Residual Torque Audit
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

Panasonic