Panasonic FV05VFL2 Installation Instructions

Panasonic FV05VFL2 Manual

Panasonic FV05VFL2 manual content summary:

  • Panasonic FV05VFL2 | Installation Instructions - Page 1
    INSTRUCTIONS. Please read these instructions carefully before attempting to install, operate or service the Panasonic Ventilating Fan. Failure to comply with instructions ( Cleaning ) Maintenance II ( Replacement Of Lamp ) Practical Guide to Installation Product Service 2 2 3 3 4 4 4-5 6-8 8-9 10 10
  • Panasonic FV05VFL2 | Installation Instructions - Page 2
    ceiling mount ventilation fans use a sirocco fan with dolphin-shaped blades driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal-cutoff for safety. The grille can be quickly detached from the main unit
  • Panasonic FV05VFL2 | Installation Instructions - Page 3
    WIRING DIAGRAM Current Fuse 3.15 A Electronic Ballast Fluorescent Lamp Fan body Motor Red T Capacitor White White - White Black Black White White Black B ack Black Green Green Green Lighting unit Neutral Live Neutral Live Power Supply AC 120 V 60 Hz Earth ground Earth ground
  • Panasonic FV05VFL2 | Installation Instructions - Page 4
    are present. GENERAL SAFETY INFORMATION 1. Do not install this ventilating fan where air temperature may exceed 40°C (104°F). 2. Make sure that the electric service supply voltage is 120 V, 60 Hz. 3. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the
  • Panasonic FV05VFL2 | Installation Instructions - Page 5
    motor humming noise. To reduce the risk of fire or electric shock, do not use this unit with any solid-state control device. H. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the
  • Panasonic FV05VFL2 | Installation Instructions - Page 6
    INSTALLATION I (JOIST MOUNTING-I) 1. Before installation, secure the fan body to adaptor by using thumb screw.(Fig.1) Connection method for 3 inches adaptor connector Thumb screw • e • e Duct tape ® 3 inches adaptor connector IMPORTANT: Remove the tape from damper and adaptor before
  • Panasonic FV05VFL2 | Installation Instructions - Page 7
    INSTALLATION I (JOIST MOUNTING-I) CONTINUED 3. Install the suspension bracket and the flange of fan body to joists by using long screws (ST4.2X20). ( If spacing A between joists is 10 1/4-12 inches, install the flange of Joist fan body according to Fig.3-2, others according to Fig.3-1 to
  • Panasonic FV05VFL2 | Installation Instructions - Page 8
    INSTALLATION I (JOIST MOUNTING-I) CONTINUED 8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.6) 9. Insert the plug connector II and plug connector M into the receptacle If and receptacle III respectively, and secure the lighting unit to the fan unit with 2
  • Panasonic FV05VFL2 | Installation Instructions - Page 9
    INSTALLATION II (JOIST MOUNTING-II ) CONTINUED 4. Insert the suspension bracket into fan body (refering to step 2 of installation I, page 6) 5. Insert the fan body into joists. (Fig.9) IMPORTANT: Make sure that adaptor claws are properly inserted into body slots. 6. Secure the fan body to adaptor
  • Panasonic FV05VFL2 | Installation Instructions - Page 10
    INSTALLATION III ( I-JOIST MOUNTING ) 4 kinds of I-joist inches (mm) C1 9/16 (14.3) C2 11/16 (17.5) c C3 31/32 (24.6) C4 1 17/32 (38.9) Fan body C3 0 0 0 0 O C4 C1 C2 Suspension bracket III The suspension bracket DI can comply with different kinds of I-joist. Thumb screw Fig.13 CID
  • Panasonic FV05VFL2 | Installation Instructions - Page 11
    INSTALLATION IV ( BETWEEN JOIST MOUNTING ) CONTINUED 3. Insert the fan body between joists. Make sure the fan body is level and square Joists (perpendicular) with the joists.(Fig.17) Ensure that distance B (7/8 inch, 21.6mm) for the thickness of ceiling board. Adaptor Fan body Junction box
  • Panasonic FV05VFL2 | Installation Instructions - Page 12
    INSTALLATION V ( WOODEN HEADER ) CONTINUED 4. Follow step 5 to 11 of installation I (page 7-page 8) to complete the installation work. Circular duct Joists is a a .! a 6 Long screws (ST4.2X20) Conduit Junction box 0 Adaptor Wire nut Lead wires Green wires Fig.21 INSTALLATION VI ( IN
  • Panasonic FV05VFL2 | Installation Instructions - Page 13
    MAINTENANCE I (CLEANING) WARNING: Disconnect power source before working on unit. Routine maintenance must be done every year. CAUTION: 1. Never use petrol, benzene, thinner or any other such chemicals for cleaning the ventilating fan. 2. Do not damp water to enter motor. 3. Do not soak resin parts
  • Panasonic FV05VFL2 | Installation Instructions - Page 14
    Fluorescent lamps Fig.26 Fig.27 PRACTICAL GUIDE TO INSTALLATION Proper insulate the area around the heat that is a common problem with recessed light fixtures or some service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT SERVICE CENTERS is maintained to support
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

INSTALLATION
INSTRUCTIONS
FV-05VFL2
FV-08VFL2
Ventilating
Fan
FV-11VFL2
FiI
1
Panasonid
READ
AND
SAVE
THESE
INSTRUCTIONS.
Please
read
these
instructions
carefully
before
attempting
to
install,
operate
or
service
the
Panasonic
Ventilating
Fan.
Failure
to
comply
with
instructions
could
result
in
personal
injury
and/or
property
damage.
Please
retain
this
booklet
for
future
reference.
Table
of
Contents
Supplied
Accessories
2
Description
2
Wiring
Diagram
3
Dimensions
3
Specifications
4
Unpacking
4
General
Safety
Information
4-5
Installation
I
(
Joist
Mounting
-I
)
6-8
Installation
II
(
Joist
Mounting
-II
)
8-9
Installation
III
(
I
-Joist
Mounting
)
10
Installation
IV(
Between
Joist
Mounting
)
10-11
Installation
V
(
Wooden
Header
)
11-12
Installation
VI
(
In
Existing
Construction
)
12
Maintenance
I
(
Cleaning
)
13
Maintenance
II
(
Replacement
Of
Lamp
)
13-14
Practical
Guide
to
Installation
14
Product
Service
14