Panasonic MVA24FBAS6HBCP Field Electric Heater for MVA Series Air Handler - Ma
Panasonic MVA24FBAS6HBCP Manual
View all Panasonic MVA24FBAS6HBCP manuals
Add to My Manuals
Save this manual to your list of manuals |
Panasonic MVA24FBAS6HBCP manual content summary:
- Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 1
Installation, Operation and Maintenance Manual How to Use this Manual: This manual gives instructions regarding installation, operation and Hazardous voltage - Disconnect and Lock Out all incoming power sources before servicing or installing unit. ELECTRIC SHOCK CAN CAUSE DEATH. WARNING: This - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 2
service. Disconnect and Lock Out all incoming power sources before connecting to electrical service the system wiring system diagram and these instructions. Wrong wiring may cause improper operation the blower deck. 3. Remove 2 screws holding heater support feet to the blower deck. 4. Remove 4 screws - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 3
supporting the heater and inserting it into the opening in the heater bulkhead. NOTE: Make sure to guide service. Disconnect and Lock Out all incoming power sources before connecting to electrical service table. Refer to test run manual for detailed instructions for changing the EEPROM settings. - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 4
or come in contact with moving parts. After servicing, position wiring properly in the original supports. All field-installed wiring, including the electrical unit. For communicating controls, refer to the condensing unit operation manual. Refer to nameplate or Electrical Ratings (page 7) for FLA, - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 5
INSTALLATION-ELECTRICAL (cont'd) TYPICAL WIRING DIAGRAMS- Electric Heat: 1-6kW and 8-9.5kW TYPICAL WIRING-ELECTRIC HEAT 035-000037-001 TYPICAL WIRING-ELECTRIC HEAT Page 5 of 8 MVA Field Heater Accessory IOM 1.0 5-19-2014 - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 6
INSTALLATION-ELECTRICAL (cont'd) TYPICAL WIRING DIAGRAMS- Electric Heat: 14.5kW and 19.5kW TYPICAL WIRING-ELECTRIC HEAT 035-000037-001 TYPICAL WIRING-ELECTRIC HEAT Page 6 of 8 MVA Field Heater Accessory IOM 1.0 5-19-2014 - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 7
UNIT ELECTRICAL RATINGS MVA Electrical Data MOTOR MVA FLA Unit 240Size 208V TOTAL ELECTRIC HT (KW) 240 208 ELECTRIC HEAT AMPS CIRCUIT 1 CIRCUIT 2 240 208 240 208 NONE NONE NONE 1.0 0.8 4.2 3.6 0.0 0.0 18/24 3.0 3.0 2.3 12.5 10.8 0.0 0.0 5.0 3.8 20.8 18.1 0.0 0.0 6.0 4.5 25.0 21.7 0.0 0.0 - Panasonic MVA24FBAS6HBCP | Field Electric Heater for MVA Series Air Handler - Ma - Page 8
Field Electric Heater Accessory for MVA Air Handling Unit Installation, Operation and Maintenance Manual 035-000037-001 Page 8 of 8 MVA Field Heater Accessory IOM 1.0 5-19-2014
035-000037-001
Page 1 of 8
MVA Field Heater Accessory IOM 1.0 5-19-2014
GENERAL
Installation and maintenance are to be per-
formed
only
by qualified personnel who are fa-
miliar with local codes and regulations and are
experienced with HVAC equipment of this type.
WARNING: Sharp edges, coil surfaces
and rotating fans are a potential injury
hazard – avoid contact.
WARNING: Hazardous voltage – Discon-
nect and Lock Out all incoming power
sources before servicing or installing unit.
ELECTRIC SHOCK CAN CAUSE DEATH.
WARNING: This equipment may be in-
stalled well above finished floor—Use ex-
treme caution when working at heights.
SAFETY WARNING:
Installer should pay particular attention to
the following words:
NOTE
–intended to clarify or make instal-
lation easier.
CAUTION
–given to prevent equipment
damage.
WARNING
–to alert installer that personal
injury and/or equipment damage may
result if installation procedure is not
properly followed.
UNPACKING-CHECK FOR DAMAGE!
Immediately inspect each unit for damage up-
on receipt.
Inspect units for external and concealed dam-
age immediately.
File any damage claims in accordance with the
Freight Damage Policy and Terms and Condi-
tions.
Do not repair damaged units without written
authorization.
Protect stored units from damage.
Field Electric Heater Accessory for
MVA Air Handling Unit
Installation, Operation and Maintenance Manual
How to Use this Manual:
This manual gives instructions regarding in-
stallation, operation and maintenance for the
Field-installed Electric Heater Accessory for
the MVA Series Air Handler.
Use these instructions in conjunction with
other appropriate instructions, including but
not limited to those instructions supplied with
the air handler and outdoor unit. Installation
must comply with all applicable local codes.
IMPORTANT!
Refer to unit installation man-
ual for general electrical installation and unit
wiring diagrams and instructions.
DANGER
NEVER enter an enclosed fan cabinet or reach into
a unit while the fan is running.
LOCK OPEN AND TAG the fan motor power dis-
connect switch before working on a fan. Take fuses
with you and note removal on tag. Electric shock
can cause personal injury or death.
LOCK OPEN AND TAG the electric heat coil power
disconnect switch before working on or near heat-
ers.
Failure to follow these warnings could lead to per-