    INSTALLATION INSTRUCTIONS System Controller Model No. CZ-64ESMC1U 85464369524010 $;&4.$6@FOHJOEE
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 2
    3 Electrical Requirements 3 Safety Instructions 3 1. General ...4 2. 18 9. Test run ...18 Product Information If you have problems or questions concerning your Air Conditioner, you will need the used in this manual, alert you to potentially dangerous conditions to users, service personnel or
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 3
    mains ON unless you will not be using this appliance for an extended period. Safety Instructions • Read this booklet carefully before using this system controller. If you still have any difficulties or problems, consult your dealer for help. • The air conditioner is designed to give you comfortable
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 4
    4 $;&4.$6@FOHJOEE 1. General This booklet briefly outlines where and how to install the system controller. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the controller before beginning. NOTE Give these
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 5
    Installation procedure (1) Remove the flat-top screw on the bottom of the back case. When you open up the decorative cover, you will see two notches under the controller. Inset a coin or other flat object into these notches and pry off the back case. (Fig.1) (2) Connect the wires to terminal base of
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 6
    Electrical Wiring DC voltage pulse DC24V Photocoupler input Allowable contact voltage and current: 24 V, 10 mA Pulse width: 300 ms or more COM No-voltage a-contact static output Allowable contact voltage and current: 30 V, 0.5 A Digital Input SYSTEM CONTROLLER A1 A2 A3 A4 A5 A6
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 7
    Basic wiring diagram of control wiring A max.of 64 indoor units and 30 outdoor units can be connected in 1system. Up to 10 system controllers can be connected in 1 systems. Outdoor unit-1 Outdoor unit-2 Indoor unit1-1 Indoor unit2-1 Remote controller Remote controller • Using Schedule Timer(
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 8
    4. Address switch setting To avoid an electric shock hazard, WARNING DO NOT touch any terminal on the Printed Circuit Board with a metal rod, a screwdriver edge nor a bare handwhen power is supplied. To Installers, After installation and adjustment, be sure to turn the BACK UP switch ON. All
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 9
    SW1 Main/sub selection switch OFF: System controller operates as main controller. ON: System controller operates as sub-controller. ALL/ZONE mode selection switch ALL mode: All indoor units can be controlled by system controller ZONE 1, 2, 3, 4 mode: Indoor units in one of zone 1, 2, 3, or 4 can
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 10
    SW2 Auxilaly switch Must be set to OFF position. Beep tone switch OFF: Beep tone when each button is pushed. ON: No tone when each button is pushed. Indication switch Normally set to OFF position. When set to ON position, indication is not displayed on LCD of system controller. *All switches are OFF
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 11
    5. Mode setting According to function of each system controller, set SW1 as Fig. 7. (1) Central control/Remote control mode Central control mode System controller is used as central control equipment. Individual setting by remote controller can be inhibitted by system controller. Remote control
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 12
    Automatic zone registration using the system controller Refer to page 16 For methods (a) and (b), you should make a zone registration table manually before performing the registration as shown on the page 13. For method (c), zone registration is executed automatically, proceeding from small indoor
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 13
    58 59 60 61 62 63 64 Indoor unit address (UNIT No.) Unit location NOTE 1. Assign indoor unit addresses to the desired positions (central addresses) manually. 2. For group control, only the main indoor unit should be assigned. Sub indoor units cannot be assigned. $;&4.$6@FOHJOEE 13
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 14
    this procedure. NOTE The indoor unit address must already have been set before performing zone registration. If necessary, refer to the Installation Instructions supplied with the outdoor unit. (1) Press the and buttons at the same time of the remote controller for more than 4 seconds. (2) Do
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 15
    (b) Zone registration using the system controller In this case, you set all Central addresses by system controller at once manually. (1) Press the and buttons at the same time for more than 4 seconds. and CODE No. C1 will flash. (2) After confirming that CODE No. C1
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 16
    (c) Automatic zone registration using the system controller (1) Press the and buttons at the same time for more than 4 seconds. and CODE No. C1 will flash. (2) Select CODE. No. C2 by pressing and ( ) button and press the button. C2 changes from flashing to ON state and automatic zone
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 17
    7. How to check overlapping of central address no. (1) Press the and buttons at the same time for more than 4 seconds. and CODE No. C1 will flash. (2) Select CODE. No. C3 by pressing , press the button. C3 changes from flashing to ON state and auto. overlap checking will start. ( ) button
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 18
    OFF ON 8. Memory back up switch Check the back up switch is ON for back side of system controller PCB. Back up switch Back up battery 9. Test run (1) Power on for all indoor units. Next, power on for system controller. will flash, checking the indoor unit address automatically. (2) If group No.
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 19
    $;&4.$6@FOHJOEE 19
  • Panasonic S-18MK1U6 | CZ-64ESMC1U Owner's Manual - Page 20
    $;&4.$6@FOHJOEE Printed in Japan
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

85464369524010
INSTALLATION INSTRUCTIONS
System Controller
Model No. CZ-64ESMC1U
CZ-64ESMC1U_eng.indd 1
CZ-64ESMC1U_eng.indd
1
2011/09/20 19:14:56
2011/09/20
19:14:56