Panasonic S-36MF2U6 S-07MF2U6 - Installation Manual

Panasonic S-36MF2U6 Manual

Panasonic S-36MF2U6 manual content summary:

  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 1
    7 9 12 15 18 24 36 48 54 S-07MF2U6 S-09MF2U6 S-12MF2U6 S-15MF2U6 S-18MF2U6 S-24MF2U6 S-36MF2U6 S-48MF2U6 S-54MF2U6 Read through the Installation Instructions before you proceed with the installation. In particular, you will need to read under the "IMPORTANT!" section at the top of the page
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 2
    service the system so it operates safely and efficiently. For safe installation and trouble-free operation, you must: ● Carefully read this instruction problem, contact our sales/service outlet or your certified dealer for additional instructions rigid and strong enough to support or hold the unit,
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 3
    . Engage authorized dealer or specialist for cleaning. • In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair. CAUTION • Do not sit or step on the unit, you may fall down accidentally. • Do not touch the air inlet or the
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 4
    18 NOTE Refer to the Operating Instructions attached to the optional Wireless Remote Service 3-2. Suspending the Indoor Unit 3-3. Installing the Drain Pipe 3-4. Connecting Duct 10-3. Operating the High-spec Wired Remote Controller (CZ-RTC3) 11. APPENDIX 25 ■ Care and Cleaning ■ Troubleshooting
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 5
    1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. 1-1. Tools Required for Installation (not
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 6
    cooled. ●●select a location where the ceiling is strong enough to support the weight of the unit. ●●select a location where tubing and total tubing length (L) from the outdoor unit as detailed in the installation manual packed with the outdoor unit. ●●allow room for mounting the remote controller
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 7
    64 (867) 42-1/64 (1,067) 57-3/4 (1,467) ●●It is recommended that space be provided (23-5/8" × 23-5/8") (600 × 600 mm) for checking and servicing the electrical system. ●●The detailed dimensions of the indoor unit is shown in Fig. 3-2 and Table 3-2. Unit: inch (mm) A (Suspension bolt pitch) Indoor
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 8
    Nuts and washers (use for upper and lower) Double nuts Suspension bolt Suspension lug Suspension bolt (3/8" or M10) (field supply) Ceiling tiles Ceiling support Fig. 3-3 Suspension bolt Hexagonal nut Double nuts Notch Fig. 3-5 Fig. 3-4 WARNING It is important that you use extreme care in
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 9
    not be allowed to hang unsupported from its connection to the unit. Fasten the pipe to a wall, frame, or other support as close to the unit as possible. (Fig. 3-13) Support pieces Vinyl clamps (field supply) Fig. 3-9 NOTE Make sure the drain pipe has a downward slant (1/100 or more) and that
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 10
    32 (150) hole. Use M5 self-tapping screws for installation. (Fig. 3-14) NOTE 1-31/32 (50) J H G H • To get clean air and to extend the service life of the air conditioner, an air filter must be installed in Type the air intake. 7, 9, 12, 15, 18 For installation and cleaning the
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 11
    4. ELECTRICAL WIRING 4-1. General Precautions on Wiring (1) Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram. WARNING (2) This equipment is strongly recommended to be installed with Earth Leakage Circuit
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 12
    with the remote controller unit (optional). Auto address setting can be executed by remote controller automatically. Refer to the installation instructions supplied with the remote controller unit (optional). (5) Ensure that the ground shield cable for inter-unit control wiring between outdoor
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 13
    CAUTION (1) When linking outdoor units in a network, disconnect the terminal extended from the short plug (on the outdoor main control PCB) from all outdoor units except any one of the outdoor units. (When shipping: In shorted condition.) For a system without link (no connection wiring between
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 14
    A fire hazard may also occur. Therefore, ensure that all wiring is tightly connected. When connecting each power wire to the terminal, follow the instructions on "How to connect wiring to the terminal" and fasten the wire securely with the fixing screw of the terminal board. How to connect wiring
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 15
    5. How to Process Tubing The liquid tubing side is connected by a flare nut, and the gas tubing side is connected by brazing. 5-1. Connecting the Refrigerant Tubing Use of the Flaring Method Many of conventional split system air conditioners employ the flaring method to connect refrigerant tubes
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 16
    caused by refrigerant leakage. ●●In order to prevent damage to the flare caused by over-tightening of the flare nuts, use the table above as a guide when tightening. ●●When tightening the flare nut on the liquid tube, use an adjustable wrench with a nominal handle length of 7-7/8 in. (200 mm
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 17
    If the exterior of the outdoor unit valves has been finished with a square duct covering, make WARNING sure you allow sufficient space to access the valves and to allow the panels to be attached and removed. Taping the flare nuts Wind the white insulation tape around the flare nuts at the gas tube
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 18
    Request that the customer be present at the time the test run is performed. Explain the Operating Instructions to the customer and then have the customer actually operate the system. ●●Be sure to pass the manual and warranty certificate to the customer. ●●Verify that the AC 208 / 230 V wiring is not
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 19
    setting (set with the PC board) TP3 or TP1 short-circuit Refer to section "10-1. How to Set on PC Board". c. Manual setting Item code "b0" : 0~15 setting (*Note (3)) (* Note (4)) Refer to section "Operating the Remote Controller (CZ‑RTC2)". d. Auto airflow volume setting (* Note (4)) Item code
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 20
    "b0". When amending the setting after selecting [ b. Manual setting] (due to airflow path changes, etc.), it is necessary to cancel [b. Manual setting] (disconnect short-circuit connector). When [b. Manual setting] has not been cancelled, [c. Manual setting] and [d. Auto airflow volume setting] will
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 21
    10-2. Operating the Timer Remote Controller (CZ-RTC2) 10-2-1. How to set the external static pressure 1. Press and hold down the , and buttons simultaneously for 4 or more seconds. ( , the Unit No., Item Code and Detailed Data will blink on the LCD display.) 2. The indoor unit numbers in the
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 22
    simultaneously for 4 or more seconds. The "Maintenance func" screen appears on the LCD display. Maintenance func 20:30 (THU) 1. Outdoor unit error data 2. Service contact 3. RC setting mode 4.Test run Sel. Page [ ] Confirm 2. Press the or button to see each menu. If you wish to see the
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 23
    press the or button. Select "4. Test run" on the LCD display and press the button. Maintenance func 20:30 (THU) 1. Outdoor unit error data 2. Service contact 3. RC setting mode 4.Test run Sel. Page [ ] Confirm The "Test run" screen appears on the LCD display. Test run 20:30 (THU) Test
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 24
    Indoor Fan Performance Item code " " Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Tap 15 H H Setting at shipment 14 HH 13 M M HH 12 HH 11 M HH 8 M MMM HH 6 LL M MM
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 25
    should be taken when you clean these parts. ●●The internal coil and other components must also be cleaned periodically. Consult your dealer or service center. Care: After a prolonged idle period Check the indoor and outdoor unit air intakes and outlets for blockage; if there is a blockage, remove
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 26
    ■■ Troubleshooting If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. ●●Indoor unit Symptom Cause Noise Sound like streaming water during ●● Sound of refrigerant
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 27
    ●●Check Before Requiring Services Symptom Cause Remedy Air conditioner does not Power failure or after power failure run at all although power is turned on. Operation button is turned
  • Panasonic S-36MF2U6 | S-07MF2U6 - Installation Manual - Page 28
    Printed in China F616469 DC0414-10814
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

INSTALLATION INSTRUCTIONS
VRF System Air Conditioner
This air conditioner uses the refrigerant R410A.
Model No.
Indoor Units
Type
Indoor Unit Type
Nominal Capacity
7
9
12
15
18
24
36
48
54
F2
Low Silhouette
Ducted
S-07MF2U6 S-09MF2U6 S-12MF2U6 S-15MF2U6 S-18MF2U6 S-24MF2U6 S-36MF2U6 S-48MF2U6 S-54MF2U6
Read through the Installation Instructions before you proceed with the installation.
In particular, you will need to read under the “IMPORTANT!” section at the top of the page.
F616469