Panasonic S-36MF2U6 S-07MF2U6- Operation Manual

Panasonic S-36MF2U6 Manual

Panasonic S-36MF2U6 manual content summary:

  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 1
    . 52 U-52LE1U6 U-52LE1U6E* Nominal Capacity 72 96 U-72ME2U9 U-96ME2U9 U-72MF1U9 U-96MF1U9 120 U-120ME2U9 144 U-144ME2U9 This air conditioner uses the refrigerant R410A. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. F569694
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 2
    Instructions attached to the optional High-spec Wired Remote Controller. ADJUSTING AIRFLOW DIRECTION 6 SPECIAL REMARKS ...7 CARE AND CLEANING ...8 TROUBLESHOOTING ...9 CHECK BEFORE REQUIRING SERVICES 10 TIPS FOR ENERGY SAVING ...10 SPECIFICATIONS ...11 PRODUCT INFORMATION If you have problems
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 3
    SAFETY INSTRUCTIONS • Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair. • Check for a leaking refrigerant! Refrigerant gas
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 4
    • For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. • Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 5
    OPERATION CONDITION 3 way system Use this air conditioner under the following temperature range. Temperature range (°F/°C) Heating & Cooling Cooling Heating Max. Min. Max. Min. Max. Min. Indoor *DBT 86/30 59/15 90/32 64/17.8 86/30 61/16 *WBT -/- -/- 77/25 57/14 -/- -/- Outdoor *DBT *WBT
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 6
    CZ-RTC2) High-spec Wired Remote Controller (Optional parts) NOTE Refer to the Operating Instructions attached to the optional High-spec Wired Remote Controller. (CZ-RTC3) ADJUSTING AIRFLOW . These must be obtained locally. Please refer to the manual of the locally adopted air outlet parts. 6
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 7
    SPECIAL REMARKS ''DRY'' Operation How it works • Once the room temperature reaches the level that was set, the unit repeats the cycle of turning on and off automatically. • In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating. •
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 8
    of the outdoor unit must be cleaned every year. Consult your dealer or service center. The air filter collects dust and other particles from the air and at the time of shipment. To get clean air and to extend the service life of the air conditioner, an air filter must be installed in the
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 9
    TROUBLESHOOTING If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center. INDOOR UNIT Symptom Cause Noise Sound like streaming water during operation or after operation
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 10
    CHECK BEFORE REQUIRING SERVICES Symptom Cause Remedy Air conditioner does not run at Power failure or after power failure all although power is turned on. Operation button is turned
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 11
    SPECIFICATIONS „ Low Silhouette Ducted (F2 type) Model Name S-07MF2U6 Power Source Cooling Capacity BTU/h kW 7,500 2.2 Heating Capacity BTU/h kW 8,500 2.5 Sound Pressure Level (H/M/L) dB(A) 33/29/25 H : inch (mm) 11-7/16 (290) Unit Dimensions W : inch (mm) 31-1/2 (800) D : inch (mm)
  • Panasonic S-36MF2U6 | S-07MF2U6- Operation Manual - Page 12
    © Panasonic Corporation 2014 Printed in China F569694 BE0414-10814
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

F569694
Operating Instructions
VRF System Air Conditioner
Model No.
This air conditioner uses the refrigerant R410A.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
* Salt-Air Damage Resistant Specifications.
Indoor Unit
7
9
12
18
Nominal Capacity
F2
Low Silhouette Ducted
S-07MF2U6
S-24MF2U6
36
U-36LE1U6
U-36LE1U6E*
52
U-52LE1U6
U-52LE1U6E*
S-09MF2U6
S-12MF2U6
S-18MF2U6
Indoor Unit Type
Type
Outdoor Units
Nominal Capacity
ME2
2WAY VRF System
MF1
3WAY VRF System
LE1
Mini VRF System
Outdoor Unit Type
Type
15
S-15MF2U6
24
36
48
S-36MF2U6
S-48MF2U6
54
S-54MF2U6
72
U-72ME2U9
U-72MF1U9
96
U-96ME2U9
U-96MF1U9
120
U-120ME2U9
144
U-144ME2U9
Connectable outdoor unit lineup
This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating
instructions supplied with the outdoor unit.