Panasonic YE9WKU1 YE Operation Manual

Panasonic YE9WKU1 Manual

Panasonic YE9WKU1 manual content summary:

  • Panasonic YE9WKU1 | YE Operation Manual - Page 1
    CS-YE9WKU1 CS-YE12WKU1 CU-YE9WKU1 CU-YE12WKU1
  • Panasonic YE9WKU1 | YE Operation Manual - Page 2
  • Panasonic YE9WKU1 | YE Operation Manual - Page 3
    CONTENTS SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER 1 NAMES OF THE PARTS ...5 INDOOR UNIT DISPLAY...6 EMERGENCY FUNCTION & AUTO-RESTART FUNCTION 7 REMOTE CONTROL ...8 OPERATING INSTRUCTIONS 12 PROTECTION ...19 INSTALLATION ...20 MAINTENANCE ...29 TROUBLESHOOTING ...30
  • Panasonic YE9WKU1 | YE Operation Manual - Page 4
    comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is COMPULSORY. SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLER Read this guide before installing and using the appliance. During the installation of
  • Panasonic YE9WKU1 | YE Operation Manual - Page 5
    above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and
  • Panasonic YE9WKU1 | YE Operation Manual - Page 6
    or electrocution. Have repairs carried out only by an authorized Service Center. Incorrect repair could exposethe user to the risk of electric shock, etc. Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every possible condition and situation
  • Panasonic YE9WKU1 | YE Operation Manual - Page 7
    or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 4
  • Panasonic YE9WKU1 | YE Operation Manual - Page 8
    NAMES OF THE PARTS INDOOR UNIT No. Description 1 Front panel 2 Air filter 3 Optional filter (if installed) 4 LED Display 5 Signal receiver 6 Terminal block cover 7 Ionizer generator(if installed) 8 Deflectors 9 Emergency button 10 Indoor unit rating label (Stick position optional) 11 Airflow
  • Panasonic YE9WKU1 | YE Operation Manual - Page 9
    INDOOR UNIT DISPLAY 12 3 45 /O 1 5 2 4 12 3 45 3 4 4 3 3 2 2 3 1245 No. Led 1 POWER 2 SLEEP 3 Temperature display (if present) /Error code 4 TIMER 5 RUN Function This symbol appears when the unit is power on SLEEP mode (1) Lights up during Timer operation when the air
  • Panasonic YE9WKU1 | YE Operation Manual - Page 10
    EMERGENCY FUNCTION & AUTO-RESTART FUNCTION If the remote controller fails to work or maintenance necessary, proceed as following: Open and lift the front panel up to an angle to reach the emergency button. Press the emergency button, the unit will operate COOL mode at first. Press again within 3
  • Panasonic YE9WKU1 | YE Operation Manual - Page 11
    REMOTE CONTROL ( NOTE: SEE ILLUSTRATION ON PAGE 89 ) No. Button Function 1 To turn on or off the air conditioner . 2 To decrease temperature, time setting or choose the function. 3 To increase temperature, time setting or choose the function. 4 Mode To select the mode of operation(AUTO
  • Panasonic YE9WKU1 | YE Operation Manual - Page 12
    REMOTE CONTROL The display and some functions of the remote control may vary according to the model. The shape and position of buttons and indicators may vary according to the model, but their function is the same. The unit confirms the correct reception of each button with a beep. 9
  • Panasonic YE9WKU1 | YE Operation Manual - Page 13
    REMOTE CONTROL Remote control DISPLAY Meaning of symbols on the liquid crystal display No. Symbols Meaning 1 Battery indicator 2 Mode Auto function indicator 3 Mode Cooling indicator 4 Mode Dry indicator 5 Mode Fan indicator 6 Mode Heating indicator 7 ECO indicator 8 Timer
  • Panasonic YE9WKU1 | YE Operation Manual - Page 14
    need to reset, take out the batteries and install again. For some model of remote controller, open the battery cover, and you can see the manual switch at the bottom, then you can select the Cooling only or Heating pump, operate as below, DIP switch on position Function C The display is
  • Panasonic YE9WKU1 | YE Operation Manual - Page 15
    OPERATING INSTRUCTIONS The air sucked by the fan enters from the grill and passes through the filter, then it is cooled/dehumidified or heated through the heat exchanger. The direction of the air outlet is motorized up and down by flaps, and manually moved right and left by the vertical deflectors,
  • Panasonic YE9WKU1 | YE Operation Manual - Page 16
    OPERATIINNGG IINNSSTTRRUUCCTTIIOONNSS COOLING MODE The cooling function allows the air conditCOOL ioner to cool the room and at the same time reduces Air humidity. To activate the cooling function ( COOL ) , press the MODE button until the symbol appears on the display. With the button or set a
  • Panasonic YE9WKU1 | YE Operation Manual - Page 17
    OPERATING INSTRUCTIONS DRY MODE DRY This function reduces the humidity of the air to make the room more comfortable. To set the DRY mode , Press MODE until
  • Panasonic YE9WKU1 | YE Operation Manual - Page 18
    OPERATING INSTRUCTIONS DISPLAY function (Indoor display) Switch ON/OFF the LED display on DISPLAY panel. Press DISPLAY button to switch off the LED display on the panel.
  • Panasonic YE9WKU1 | YE Operation Manual - Page 19
    OPERATING INSTRUCTIONS ECO function ECO In this mode the appliance automatically sets the operation to save energy. Press the ECO button, the appears on the display, and
  • Panasonic YE9WKU1 | YE Operation Manual - Page 20
    OPERATING INSTRUCTIONS TIMER function ---- TIMER ON TIMER To automatic switch on the appliance. When the unit is switch-off, you can set the TIMER ON. To set
  • Panasonic YE9WKU1 | YE Operation Manual - Page 21
    OPERATING INSTRUCTIONS I FEEL function (Optional) I FEEL Press I FEEL button to active the function, the will appear on the remote display. Do it again to deactivate this function.
  • Panasonic YE9WKU1 | YE Operation Manual - Page 22
    PROTECTION The protective device may trip and stop the appliance in the cases listed below. MODEL Temperature Room Temperature Cooling operating 17 ~32 63 ~89 Heatling operating Drying operating 0 ~30 32 ~86 17 ~32 63 ~89 15 ~53 59 ~127 Outdoor Temperature -15 ~53 5 ~127 For models with low
  • Panasonic YE9WKU1 | YE Operation Manual - Page 23
    be less than 16.40 ft Height should be less than 16.40 ft Only persons and/or companies qualified and experienced in the installation, service and repair of refrigerant products should be permitted to do so. The purchaser must ensure that the person and/or company who is to install
  • Panasonic YE9WKU1 | YE Operation Manual - Page 24
    INSTALLATION MANUAL---Installation of the Indoor unit Before starting installation, decide must be ensured. 8. If the power cable is damaged, it must be replaced by an authorised Service Centre. Note:The cable wires has been connected to the main PCB of indoor unit by manufacturer according
  • Panasonic YE9WKU1 | YE Operation Manual - Page 25
    INSTALLATION MANUAL---Installation of the Indoor unit Refrigerant piping connection The piping can be ran in 3 directions (indicated by numbers in the pictures). When the piping is
  • Panasonic YE9WKU1 | YE Operation Manual - Page 26
    MANUAL---Installation of the Indoor unit INSTALLATION OF THE INDOOR UNIT After having connected the pipe according to the instructions, leave enough space to be able to carry out maintenance easily. Fasten the support to the wall using screw anchors which are particularly suited to the type
  • Panasonic YE9WKU1 | YE Operation Manual - Page 27
    INSTALLATION MANUAL---Installation of the outdoor unit ELECTRICAL CONNECTIONS 1. Remove the handle on the right side plate of outdoor unit 24. connection pipes flare nuts liquid tap gas tap indoor unit gas valve liquid valve tap service port nut protection caps service port vacuum pump 24
  • Panasonic YE9WKU1 | YE Operation Manual - Page 28
    INSTALLATION MANUAL---Installation of the outdoor unit BLEEDING INSTALLATION MANUAL---operation test Wrap applying correctly? correctly? correctly? correctly? 25
  • Panasonic YE9WKU1 | YE Operation Manual - Page 29
    INSTALLATION MANUAL---Information for the installer INVERTER TYPE MODEL capacity (Btu/h) Liquid pipe diameter CORRESPONDING STRESS (using a 20 cm wrench) wrist strength arm strength arm strength arm strength Service port nut Protection caps TIGHTENING TORQUE [lbf x ft] 5.17-6.64 18.45-22.14 26
  • Panasonic YE9WKU1 | YE Operation Manual - Page 30
    INSTALLATION MANUAL---Information for the installer WIRING DIAGRAM For different models, the wiring diagram may be different. Please refer to the wiring diagrams affixed to the indoor
  • Panasonic YE9WKU1 | YE Operation Manual - Page 31
    INSTALLATION MANUAL---Information for the installer CABLE WIRES SPECIFICATION INVERTER TYPE MODEL capacity (Btu/h) N(L2) Power supply cable L(L1) 3(L) 2(N) Connection supply cable 1(S) 9K-115V sectional area 3.0mm2
  • Panasonic YE9WKU1 | YE Operation Manual - Page 32
    MAINTENANCE Periodic maintenance is essential for keeping your air conditioner efficient. Before carrying out any maintenance, turn the power supply off . INDOOR UNIT ANTIDUST FILTERS 1. Open the front panel (following the direction of the arrow). 2. Keeping the front panel raised with one hand,
  • Panasonic YE9WKU1 | YE Operation Manual - Page 33
    TROUBLESHOOTING front panel due to variations in temperature and does not indicate a problem. Unsuitable temperature setting. Obstructed air conditioner intakes and outlets. Dirty codes: Display Description of the trouble Display Description of the trouble Indoor temperature sensor fault Outdoor
  • Panasonic YE9WKU1 | YE Operation Manual - Page 34
    • Consult the dealer or an experienced radio/TV technician for help. FCC Caution: To assure continued compliance, follow the attached installation instructions. Any changes or modifications not expressly approved by the party responsible for compliance could void the user´s authority to operate this
  • Panasonic YE9WKU1 | YE Operation Manual - Page 35
  • Panasonic YE9WKU1 | YE Operation Manual - Page 36
    of North America Panasonic Appliances Air-Conditioning North America 1690 Roberts Blvd., NW, Suite 110, Kennesaw, GA 30144 U.S.A. us.panasonic.com/hvac Customer Service: 800-851-1235 Panasonic Canada Inc. Enterprise Product Sales 5770 Ambler Dr., Mississauga, ON, L4W 2T3 CANADA na.panasonic.com/ca
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

CS-YE9WKU1
CS-YE12WKU1
CU-YE9WKU1
CU-YE12WKU1