ProForm 530x Treadmill English Manual - Page 6

Assembly - walking belt

Page 6 highlights

ASSEMBLY Assembly requires two persons. Set the treadmill in a cleared area and remove all packing materials. Do not dispose of the packing materials until assembly is completed. Note: If a part needed for assembly is not in the parts bag, first check to see if it has been pre-assembled. If a part is missing, call toll-free 1-800-999-3756. Assembly requires your own Phillips screwdriver and rubber mallet . Note: The underside of the treadmill walking belt is coated with high-performance lubricant. During shipping, a small amount of lubricant may be transferred to the top of the walking belt or the shipping carton. This is a normal condition and does not affect treadmill performance. If there is lubricant on top of the walking belt, simply wipe off the lubricant with a soft cloth and a mild, non-abrasive cleaner. 1. With the help of a second person, carefully raise the treadmill to the upright position as shown. If there are 1 plastic ties on the pulse sensors, remove them. Insert one of the Extension Legs (55) into the treadmill as shown. Make sure that the Extension Leg is turned so the Base Pad (44) is on the bottom. If necessary, tip the Uprights (64) forward as you insert the Extension Leg. Insert the other Extension Leg (not shown) in the same way. Ties 64 2. With the help of a second person, carefully lower the Uprights (64) as shown. Note: It may be helpful to place your foot on one of the Wheels (58) as you tip the Uprights. Make sure that the Extension Legs (55) remain in the Uprights. Attach each Extension Leg (55) with an Extension Screw (35), a 1" Screw (13), and a Base Pad (44) as shown. Note: One replacement Base Pad (44) may be included. If a Base Pad becomes worn and needs to be replaced, use the replacement Base Pad. 2 64 35 55 13 44 58 35 6 55 44 35 55 13 44 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30

ASSEMBLY
Assembly requires two persons.
Set the treadmill in a cleared area and remove all packing materials. Do not
dispose of the packing materials until assembly is completed. Note: If a part needed for assembly is not in the
parts bag, first check to see if it has been pre-assembled.
If a part is missing, call toll-free 1-800-999-3756.
Assembly requires your own Phillips screwdriver
and rubber mallet
.
Note: The underside of the treadmill walking belt is coated with high-performance lubricant. During shipping, a
small amount of lubricant may be transferred to the top of the walking belt or the shipping carton. This is a normal
condition and does not affect treadmill performance. If there is lubricant on top of the walking belt, simply wipe off
the lubricant with a soft cloth and a mild, non-abrasive cleaner.
1.
With the help of a second person, carefully raise the
treadmill to the upright position as shown. If there are
plastic ties on the pulse sensors, remove them.
Insert one of the Extension Legs (55) into the treadmill as
shown. Make sure that the Extension Leg is turned so
the Base Pad (44) is on the bottom. If necessary, tip the
Uprights (64) forward as you insert the Extension Leg.
Insert the other Extension Leg (not shown) in the same
way.
2.
With the help of a second person, carefully lower the
Uprights (64) as shown. Note: It may be helpful to place
your foot on one of the Wheels (58) as you tip the
Uprights.
Make sure that the Extension Legs (55) re-
main in the Uprights.
Attach each Extension Leg (55) with an Extension Screw
(35), a 1” Screw (13), and a Base Pad (44) as shown.
Note: One replacement Base Pad (44) may be included.
If a Base Pad becomes worn and needs to be replaced,
use the replacement Base Pad.
64
Ties
55
1
35
13
13
44
55
44
35
55
64
58
6
44
2
35
13