    OPERATING INSTRUTIONS DIGITAL MULTIMETER PDMT08 www.pyleaudio.com 1
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 2
    SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. 1.
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 3
    This symbol adjacent to another symbol, terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions to avoid personal injury or damage to the meter. WARNING This WARNING symbol indicates a potentially hazardous situation, which if not avoided
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 4
    MAX result damage to the product. This symbol advises the user that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to earth ground exceeds (in this case) 500 VAC or VDC. This symbol adjacent to one or more terminals identifies them as being
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 5
    CONTROLS AND JACKS 1. LCD Display 2. Function switch 3. 10A jack 4. COM jack 5. Positive jack Note: Tilt stand, fuse and battery compartment are on rear of unit. 5
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 6
    SYMBOLS AND ANNUNCIATORS •))) Continuity Diode test  micro (amps) m milli ( volts, amps) k kilo (ohms)  ohms VDC volts direct current VAC volts alternating current ADC amps direct current BAT Battery test SPECIFICATIONS Function Range Resolution Accuracy DC Voltage 200mV
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 7
    200V 0.1V 600V 1V AC Voltage 200V 0.1V (V AC) 600V 1V DC Current 2000A 1A (A DC) 20mA 10A 200mA 100A 10A 10mA Resistance 200 0.1 2000 1 20k 0.01k 200k 0.1k Battery Test 2000k 1k 9V 10mV 1.5V 10mV (0.8% reading + 2 digits) (1.2% reading + 10 digits (50/60Hz)
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 8
     (% reading) - This is the accuracy of the measurement circuit.  (+ digits) - This is the accuracy of the analog to digital converter. NOTE: Accuracy is stated at 65oF to 83oF (18oC to 28oC) and less than 75% RH. SPECIFICATIONS Diode Test Continuity Check Battery Test current Input Impedance ACV
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 9
    polarity); Minus (-) sign for negative polarity. Measurement Rate 2 times per second, nominal Low Battery Indication "BAT" is displayed if battery voltage drops below operating voltage Battery one 9 volt (NEDA 1604) battery Fuses Operating Temperature Storage Temperature mA, µA ranges; 0.2A/
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 10
    meter does not work properly, check the fuses and batteries to make sure that they are still good and that they are properly inserted. OPERATING INSTRUCTIONS WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 10
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 11
    1.ALWAYS turn the function switch to the OFF position when the meter is not in use. 2.If "OL" appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. NOTE: On some low AC and DC voltage ranges, with the test leads not connected to a
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 12
    negative side of the circuit. Touch the red test probe tip to the positive side of the circuit. 4. Read the voltage in the display. Reset the function switch to successively lower V DC positions to obtain a higher resolution reading. The display will indicate the proper decimal point and value. If
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 13
    1. Set the function switch to the highest V AC position. 2. Insert the black test lead banana plug into the negative (COM) jack. Insert red test lead banana plug into the positive (V) jack. 3. Touch the black test probe tip to the negative side of the circuit. Touch the red test probe tip to the
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 14
    2. For current measurements up to 200mA DC, set the function switch to the highest DC mA position and insert the red test lead banana plug into the (mA) jack. 3. For current measurements up to 10A DC, set the function switch to the 10A range and insert the red test lead banana plug into the (10A)
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 15
    RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords. 1. Set the function switch to the highest  position. 2. Insert the black test
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 16
    CONTINUITY CHECK WARNING: To avoid electric shock, never measure continuity on circuits or wires that have voltage on them. 1. Set the function switch to the position. 2. Insert the black lead banana plug into the negative (COM) jack Insert the red test lead banana plug into the positive () jack
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 17
    indicate "I" in both polarities. BATTERY TEST 1. Insert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack. 2. Select the 1.5V or 9V BAT position using the function select switch. 3. Connect the red test lead to the positive side
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 18
    " will appear in the right-hand side of the LCD display. The batteries should be replaced. 2. Follow instructions for installing batteries. See the Battery Installation section of this manual. 3. Dispose of the old batteries properly. WARNING: To avoid electric shock, do not operate your meter until
  • Pyle PDMT08 | PDMT08 Manual 1 - Page 19
    4. Install the new fuse into the holder. 5. Always use a fuse of the proper size and value (0.5A/250V fast blow for the 200mA range, 10A/250V fast blow for the 10A range). 6. Put the fuse door back in place. Insert the screw and tighten it securely. WARNING: To avoid electric shock, do not operate