    USE AND CARE INSTRUCTIONS FOR YOUR AIR COOLED CONDENSING UNIT Thermostat Operation We find most air conditioning units are installed with a single stage heating and cooling thermostat which includes a manual heat/cooling system switch and a manual/auto fan switch. For cooling, position the system
  • Rheem RAPM-JAZ | User Instructions - Page 2
    manual high pressure switch reset button, have your servicing contractor familiarize you with its location. Many models have compressors reset it as required. However, If the problem persists, refer to item 8, and/or refer the problem to your servicing contractor. 7. If the condenser coil is allowed
  • 1
  • 2

Thermostat Operation
We find most air conditioning units are installed with a
single stage heating and cooling thermostat which includes
a manual heat/cooling system switch and a manual/auto
fan switch.
For cooling, position the system switch to “cool” and the
fan switch to “auto.” If constant fan operation is desired,
place the fan switch in the “on” position.
When heating is desired, position the system switch to call
for heating and place the fan switch in the “auto” position.
We suggest that you experiment with
constant air circula-
tion
during the heating and cooling cycles. To achieve this
style of operation, place the fan switch on the thermostat
subbase to the “on” position. You may enjoy the comfort
associated with the continuous air movement, constant air
filtration, and the near even temperature from floor to ceil-
ing.
Selection of Room Temperature
It is most important to select the comfort temperature you
desire for either heating or cooling by use of the thermo-
stat temperature selector.
DO NOT PLAY WITH THE THERMOSTAT, SET IT AND
FORGET IT.
If the temperature selection procedure is new to you, ask
your installing contractor to familiarize you with the opera-
tion of the thermostat.
System Operation Information
1. Keep the filter clean. Your system will operate more
efficiently and provide better conditioned air, more eco-
nomically.
2. Arrange your furniture and drapes so that the supply
and return air registers and grilles are unobstructed.
3. Close doors and windows. This will reduce the cooling
load on your system for a more economical operation.
4. Avoid excessive use of kitchen exhaust fans.
5. Window shades and awnings will reduce the cooling
load.
6. Unless you plan to clean the coil in the outdoor unit, do
not disconnect the main power to your unit. This is a
safety precaution for the protection of the compressor.
Otherwise, use the thermostat switches to shut the
system off.
7. For extended periods of inoperation, set the thermostat
system switch in the off position and the fan switch in
the auto position.
8. If unit is shut off at thermostat, wait 5 minutes before
restarting.
9. We suggest that you do not allow the outdoor unit to
become a play stand for children. This could be dan-
gerous to the child.
10. A regular period of waxing the finish on an outdoor unit
will increase the life of the finish.
11. Remember to keep the air filters clean for efficiency
and energy saving operation.
Things You May Do
1.
WARNING: Turn off main electrical power to the
outdoor unit or indoor unit before attempting any
maintenance operation.
2. Keep air filters clean. There are several types of mate-
rials used in air filters and there are many possible
locations for air filters. Consult with your contractor as
to the location of the filters and type of material in use.
3. How To Clean:
Glass Fiber—(Throwaway) This is a disposable type of
filter. Inspect monthly and replace when necessary. A
new home will normally require more frequent attention
to the filters.
Aluminum Mesh—Wash with detergent and water. Air
dry thoroughly and renew the coating in compliance
with the manufacturer’s instructions.
Plastic Impregnated Fiber—Wash with detergent and
water or vacuum clean, then reinstall.
CAUTION: DO NOT OPERATE YOUR
SYSTEM FOR EXTENDED PERIODS
WITHOUT FILTERS, AS THE DUST EN-
TRAINED IN THE AIR MAY PACK INTO
THE FIN AREA OF THE INDOOR COIL
CREATING A CONDITION WHICH COULD
REQUIRE EXTENSIVE REPAIRS.
4. Oiling of Electrical Motors:
The blower motor sleeve bearings are prelubricated by
the motor manufacturer and may not require attention
for an indefinite period of time. However, our recom-
mendations are as follows:
A. Motors without oiling ports—
Prelubricated and sealed. No further lubrication
should be required, but in case of bearing problems,
the blower and the motor end bells of some motors
can be disassembled and the bearings relubricated
by a qualified service person.
B. Motors with oiling ports—
Add from 10 to 20 drops of Electric Motor Oil or an
SE grade of non-detergent SAE-10 or 20 motor oil
to each bearing every two years for somewhat con-
tinuous duty, or at least every five years for light
duty. Take care not to over oil, because excessive
lubrication can damage the motor.
92-20802-01-12
SUPERSEDES 92-20802-01-11
USE AND CARE INSTRUCTIONS
FOR YOUR AIR COOLED CONDENSING UNIT