Rheem Warrior DVX Series User Guide

Rheem Warrior DVX Series Manual

Rheem Warrior DVX Series manual content summary:

  • Rheem Warrior DVX Series | User Guide - Page 1
    allon Heaters ONLY!! Placement of water heater. Locate and install the water heater following the instructions in the Use and Care Manual, make certain the minimum clearances outlined in the Use and Care Manual are observed. S electing the roof jack module. The Co-axial vent roof jack is divided
  • Rheem Warrior DVX Series | User Guide - Page 2
    Top Plenum Flue Pipe. Brackets on Bottom of Roof Jack Silicone Band Screws to inside top of top pan. Figure 6 Silicone Band Silicone Band Figure 5 Apply silicone around the top plenum opening. Lower Roof Jack Module Installation. Install the lower roof jack module into the roof. The 3"
  • Rheem Warrior DVX Series | User Guide - Page 3
    Safety Standard (Title 24, CFR; Part 3280), the following instructions, local codes and utility company requirements governing the installation of distance from the top of the water heater to the ceiling for servicing the water heater. Adjustable Tilt Roof Flange Roof Jack (Purchased Separately)
  • 1
  • 2
  • 3

Instruction Sheet for Manufactured Home DV Co-Axial Kit
MANUFACTURED HOME FACTORY INSTALLATION
INSTRUCTIONS AND TRANSPORTATION SET-UP
Inspect shipment.
Inspect the contents of the kit for possible
damage. Verify the quantity of the components in the kit. The kit
includes: (A) 1- Co-Axial Roof Jack; (B) 3- Plastic Lock Ties;
(C) 1- Rain Cap; (D) 1- Co Axial Kit Instruction Sheet;
(E) 3- Warning Tag Labels and (F) 1- Carton Warning Label.
Please report any shortage to your local distributor or contact
1-800-432-8373 to get a replacement part. (See Figure 1)
The (3) “Warning Tag Labels” should be attached with the
plastic lock tie in the following locations:
(1) Gas Line Outside of Manufactured Home
(2) Master Shutoff Valve to Home
(3) Gas Valve on Water Heater
Locating Clearance Hole for Vent Cutout.
Cut a 7 ¼"
diameter hole in the ceiling and roof directly above the flue
of the water heater.
Placement of water heater.
Locate and install the water
heater following the instructions in the Use and Care
Manual, make certain the minimum clearances outlined in
the Use and Care Manual are observed.
Selecting the roof jack module.
The Co-axial vent roof
jack is divided into two modules . The lower module (See
Figure. 4) should be installed on the water heater at the fac-
tory location. The upper roof jack module (See Figure. 3)
should remain in the co-axial carton box and shipped inside
the manufactured home for assembly and setup at the per-
manent location of the home.
A
. Disassemble the upper
roof jack module by
expanding the "D" ring as
shown in Figure 3.
DO
NOT
remove the silicone
band attached to the 3"
pipe; it will be used for
final assembly at the per-
manent location of the
home.
B
. Install the rain cap on
the lower roof jack module
with the supplied "D" ring.
C
. Place the upper roof jack module back into the carton .
Seal the carton with the bright orange Carton Warning
Label (F) supplied. Make sure the carton box ships with the
manufactured home for final assembly of the vent system at
the permanent location of the home.
!
WARNING! THIS HOME HAS BEEN SHIPPED WITHAN INCOMPLETE WATER HEATER
VENTING SYSTEM FOR TRANSPORTATION USE ONLY. DO NOT CONNECT THE FUEL
SUPPLY TO THE HOME ORATTEMPT TO OPERATE THE WATER HEATER BEFORE
COMPLETION OF THE INSTALLATION OF THE UPPER ROOF JACK MODULE (ROOF JACK
CARTON STORED INSIDE HOME). FAILURE TO REMOVE TRANSPORTATION MODE RAIN
CAPAND TO INSTALL UPPER ROOF JACK MODULE MAY RESULT IN FIRE,
EXPLOSION OR ASPHYXIATION.
Figure 4 - Lower Roof Jack Module
Center Line of 7¼"
Diameter Hole in Roof
and Ceiling
Figure 2 -Vent Cutout
1
WARNING
INSTRUCTIONS
FOR KIT
IMPORTANT
THIS HOME HAS BEEN SHIPPED WITH
AN INCOMPLETE WATER HEATER VENTING
SYSTEM FOR TRANSPORTATION ONLY
CHECK ROOF OF HOME TO BE SURE THAT COMPLETE
FLUE ASSEMBLY HAS BEEN CORRECTLY INSTALLED
BEFORE ATTEMPTING TO OPERATE THE WATER HEATER.
(A) Co-Axial Roof Jack
(B) Plastic Lock Tie
(Qty. of 3)
(C) Rain Cap
(D) Co
Axial Kit
Instruction
Sheet
(E) Warning
Tag Labels
(F) Carton
Warning
Label
Figure 1-Kit Components
AP14417 (05/07)
Figure 3 -Upper Roof Jack Module
5" Outer Pipe
3" Inner Pipe
"D" Ring
Pull
Pull