Ricoh FW780 Service Manual - Page 376
B047/B048, Mode No., Function, 0.1 second, 2 minutes, 3 intervals, 4 seconds, Original Hold mode
View all Ricoh FW780 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 376 highlights
SERVICE TOOLS Mode No. Function Data Leading Edge This sets the speed at which the Changes every: Increase/Decrease leading edge setting increases or 0: 0.1 second Speed Setting decreases. 1: 0.50 second *8 When the customer holds down the + 2: 0.25 second or - key, there is a brief pause. After a 3: 0.05 second selected number of 0.25 second 4: 0.02 second intervals (See SP 12), the values begin to change at the selected speed. Auto Reset Time Setting *9 Sets the delay for the auto reset. After finishing a copy job, the machine will wait the specified amount of time. If no other jobs are begun, it will then 0: 2 minutes 1: 1 minutes 2: 3 minutes 3: 4 minutes automatically reset the copy settings to 4: 5 minutes its default values. 5: No auto reset Auto Energy Saver *10 Mode Enables and disables the auto energy saver mode. If enabled, the machine will automatically go into energy saver 0: No 1: Auto Energy Saver Mode mode after it auto resets. Screen Message Setting *11 Selects one of the options indicated on the display in the energy saver mode. 0: None 1: Pre-HEAt 2: Hello i lovE yoU 3: 0 1 2 3 4 5 6 7 8 9 4: SLEEPinG 5: HavE A Good dAy. Leading Edge When the user hold downs the + or - Increase/Decrease key to change the leading edge Adjustment margin, print number or paper length, *12 Preliminary Interval there is a pause before the values begin to change rapidly. 0: 3 intervals 1: 1 intervals 2: 2 intervals 3: 10 intervals This paused is measured in 0.25 second intervals. Original Feed Out Waiting Time *13 Setting Original Feed Start Time Setting *14 *15 Auto Shut-off Time Setting Original Hold Mode *16 Sets the original time-out. The timer begins when an original is placed on the original table in manual feed mode (B048 copiers only). After the selected time, the original is automatically ejected. Sets the delay between when the original entrance sensor or original rear sensor is actuated, and when the original feed roller begins rotating (B048 copier only). Determines the auto shut-off time. After original scanning is finished, the original exit roller stops before completely feeding out the original. This prevents the original from falling onto the floor after scanning. The original is fed out when the ! key is pressed or when the next original is inserted into the rear feed. (B048 copier only). 0: 2 minutes 1: 1 minute 2: 3 minutes 3: 4 minutes 4: 5 minutes 5: No auto feed out 0: 1 second 1: 2 seconds 2: 3 seconds 3: 4 seconds 4: 5 seconds 5: 6 seconds 6: 7 seconds 1 ← 30 → 240 0: No 1: Original Hold mode B047/B048 4-2 SM