Ricoh FW780 Service Manual - Page 409
FUSING TEMPERATURE ADJUSTMENT, When the main switch is turned
View all Ricoh FW780 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 409 highlights
5.1.9 FUSING TEMPERATURE ADJUSTMENT FUSING Replacement and Adjustment [A] [B] B047R538.WMF !CAUTION When the main switch is turned on, the machine will suddenly start to drive the fusing section. However, this does not occur immediately. The machine waits until the hot roller is heated to above 80°C. Keep your hands away from any mechanical and electrical components during this period. This procedure is required only when the hot roller thermistor is replaced. Adjustment standard: Mode 1 (165°C), Mode 2 (170°C), Mode 3 (175°C), Mode 4 (180°C), Mode 5 (190°C), Mode 6 (193°C), Mode 7 (198°C) 1. Turn off the main switch. 2. Remove the copier rear cover. 3. Remove the pressure roller thermistor screw and hang the thermistor by the harness. 4. Actuate the fusing exit safety switch [A]. 5. Turn on the main switch, select the normal fusing temperature mode, and wait for at least 10 minutes. 6. Using a digital thermometer and probe [B], measure the temperature at the middle of the hot roller. 7. If the actual temperature is different from the value for the mode being used (use SP#1 to find out the current mode), adjust the temperature using SP#-7. 8. Repeat steps 5 to 7 and confirm the temperature. 9. Reassemble the machine. SM 5-3 B047/B048