Sanyo PLC-HF15000L RS232 Basic

Sanyo PLC-HF15000L - 15000 Lumens Manual

Sanyo PLC-HF15000L manual content summary:

  • Sanyo PLC-HF15000L | RS232 Basic - Page 1
    BASIC SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-HF15000L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Business Division
  • Sanyo PLC-HF15000L | RS232 Basic - Page 2
    PLC-HF15000L Basic Serial Command Functional Specifications Contents 1 Overview ...4 2 Serial Interface Specification 4 2.1 Transfer Specification 4 2.2 Connection ...4 3 Notes for Communication 5 4 Functional Execution Command Table 6 5 Status Read Command Table 6 6 Functional
  • Sanyo PLC-HF15000L | RS232 Basic - Page 3
    PLC-HF15000L Basic Serial Command Functional Specifications 6.32 LENS SHIFT UP Command 13 6.33 LENS SHIFT DOWN Command 13 6.34 LENS SHIFT LEFT Command 13 6.35 LENS Read Command 19 7.5 Lamp Time Read Command 19 7.6 Setting Read Command 19 7.7 Temp Read Command 20 7.8 Lamp Mode Read Command 20
  • Sanyo PLC-HF15000L | RS232 Basic - Page 4
    defines projector control commands for the PLC-HF15000L The projector control commands are designed to remote-control a projector in Service Mode. 2.2 Connection Dedicated serial cables that come with a projector must be used for the connection to a computer and the projector. PC Projector COM
  • Sanyo PLC-HF15000L | RS232 Basic - Page 5
    PLC-HF15000L Basic Serial Command Functional Specifications 3 Notes for Communication The projector command is defined one command per line that starts "C" and ends carriage return (0x0D). When the projector 1) [ZOOM UP/DOWN] [FOCUS UP/DOWN] [LENS SHIF UP/DOWN/LEFT/ RIGHT] commands...100ms 2) Other
  • Sanyo PLC-HF15000L | RS232 Basic - Page 6
    PLC-HF15000L Basic Serial Command Functional LENS SHIFT DOWN LENS SHIFT LEFT LENS SHIFT RIGHT AUTO PC ADJ. PRESENTATION TIMER PRESENTATION TIMER (Exit) KEYSTONE ↑ KEYSTONE ↓ KEYSTONE → KEYSTONE ← 5 Status Read Command Table Command Item CR0 Status Read CR1 Input Mode Read CR3 Lamp
  • Sanyo PLC-HF15000L | RS232 Basic - Page 7
    PLC-HF15000L Basic Serial Command Functional Specifications 6 Functional Execution Command 6.1 Format 1) PC issues a command in the format below: "C" Command [CR] Command: two characters (Refer to Functional Execution Command Table) 2) A projector decodes the received data and returns the result
  • Sanyo PLC-HF15000L | RS232 Basic - Page 8
    PLC-HF15000L Basic Serial Command Functional Specifications 6.4 Operation Requirements When the projector is in the status below, Functional Execution Commands are limited. (Status Read Commands are available in following status) Projector Status In Standby status Available Functional Execution
  • Sanyo PLC-HF15000L | RS232 Basic - Page 9
    PLC-HF15000L Basic Serial Command Functional Specifications 6.8 INPUT 2 Command COMMAND "C06" [CR] Detail Select Input 2 Note) When there is no board inserted to Input 2, it is not
  • Sanyo PLC-HF15000L | RS232 Basic - Page 10
    PLC-HF15000L Basic Serial Command Functional Specifications 6.14 SCREEN FULL SIZE Command COMMAND " 6.18 IMAGE Command COMMAND "C27" [CR] Detail Switch Image setting. In the case of the projector and remote control possessing an "IMAGE" button, this command work as an "IMAGE" function. Response
  • Sanyo PLC-HF15000L | RS232 Basic - Page 11
    PLC-HF15000L Basic Serial Command Functional Specifications 6.20 D.ZOOM - Command COMMAND of On Screen Display Menu to the right This command works the same way as "►" button of the projector and remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.22 POINTER LEFT Command
  • Sanyo PLC-HF15000L | RS232 Basic - Page 12
    PLC-HF15000L Basic Serial Command Functional Specifications 6.26 FREEZE ON Command and clear) with a long-focal-length ( ) (The lens direction is backward) This command works the same way as "FOCUS ▲" button of the projector and remote control. Response Acceptable [ACK] [CR] Unacceptable "?"
  • Sanyo PLC-HF15000L | RS232 Basic - Page 13
    PLC-HF15000L Basic Serial Command Functional Specifications 6.31 FOCUS - Command COMMAND "C4A" [CR] Detail Adjust focus of screen image (sharp and clear) with a short-focal-length (The lens direction is forward) This command works the same way as "FOCUS ▼" button of the projector and remote
  • Sanyo PLC-HF15000L | RS232 Basic - Page 14
    PLC-HF15000L Basic Serial Command Functional Specifications 6.37 PRESENTATION TIMER Command COMMAND "C8A" [CR] Detail Start timer to count time for presentation This command works the same
  • Sanyo PLC-HF15000L | RS232 Basic - Page 15
    PLC-HF15000L Basic Serial Command Functional Specifications 7 Status Read Command 7.1 Format 1) PC issues a command in the format below: "CR" Command [CR] Command: Single character (Refer to Status Read Command Table) 2) When a projector receives the appropriate command, it returns the required
  • Sanyo PLC-HF15000L | RS232 Basic - Page 16
    PLC-HF15000L Basic Serial Command Functional Specifications 7.3 Status Read Command COMMAND "CR0" [CR] Detail Get the projector status Acceptable "%1" [CR] Response Down status. This status automatically moves to Standby when the lamp is turned off and the fan spin finishes after about 90
  • Sanyo PLC-HF15000L | RS232 Basic - Page 17
    PLC-HF15000L Basic Serial Command Functional Specifications "10" [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal level, the status automatically moves to Power OFF. Abnormal power supply voltage includes; Filter abnormal status Shutter abnormal status
  • Sanyo PLC-HF15000L | RS232 Basic - Page 18
    PLC-HF15000L Basic Serial Command Functional Specifications "81" [CR] Status: Standby after Cooling Down due to lamp failure This value is returned when Cooling Down operation due to lamp the next operation starts. When projector is turned on again, it cancels the last status and starts normal operation.
  • Sanyo PLC-HF15000L | RS232 Basic - Page 19
    PLC-HF15000L Basic Serial Command Functional Specifications 7.4 Input Mode Read Command COMMAND "CR1" [CR] Detail sequence with one space between each of them. %1 = lamp No.1 %2 = lamp No.2 ex; "00410_00410" [CR] Lamp No.1 = 410 Hours Lamp No.2 = 410 Hours Unacceptable "?" [CR] 7.6 Setting
  • Sanyo PLC-HF15000L | RS232 Basic - Page 20
    PLC-HF15000L Basic Serial Command Functional Specifications 7.7 Temp Read Command COMMAND "CR6" [CR] Detail Get the temperature information inside projector With more than one temperature sensors installed in the projector, it is possible to get all temperatures at once. Acceptable "%1 %2" [CR]
  • Sanyo PLC-HF15000L | RS232 Basic - Page 21
    PLC-HF15000L Basic Serial Command Functional Specifications 8 Command with Address Specification 8.1 Overview - Commands with address are used to control more than one projector Command: "A001CR0" [CR] - Projector has the function to set up its own address in Service mode. Initial setting is "No.
  • Sanyo PLC-HF15000L | RS232 Basic - Page 22
    PLC-HF15000L Basic Serial Command Functional Specifications 8.2 Functional Execution Command with address 8.2.1 Format 1) PC received data cannot be decoded However, when the address is "FFF", the projector executes the function but does not return any response. 8.2.2 When the command pipelining
  • Sanyo PLC-HF15000L | RS232 Basic - Page 23
    PLC-HF15000L Basic Serial Command Functional Specifications 8.3 Status Read Command with Address 8.3.1 Format ("001"-"999") Command: String (Refer to Basic and Expand Serial Commands) 2) The only projectors that have the address matching with the one in the received data decode the command, and it
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

BASIC SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-HF15000L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Business Division