Sanyo PLC-WL2503 RS232C Basic

Sanyo PLC-WL2503 - 2500 Lumens Manual

Sanyo PLC-WL2503 manual content summary:

  • Sanyo PLC-WL2503 | RS232C Basic - Page 1
    BASIC SERIAL COMMAND SPECIFICATIONS PLC-WL2500 PLC-WL2501 PLC-WL2503 Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division
  • Sanyo PLC-WL2503 | RS232C Basic - Page 2
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications CONTENTS 1. Overview ...4 2. Serial Interface Specifications 4 2.1. Transfer Specifications 4 2.2. Connection ...4 3. Notes for Communication 5 4. Functional Execution Command Table 6 5. Status Read Command Table 8 6. Functional
  • Sanyo PLC-WL2503 | RS232C Basic - Page 3
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.32. BRIGHTNESS + Command 15 6.33. BRIGHTNESS - Command Operation Requirements 21 7.4. Status Read Command 22 7.5. Input Mode Read Command 24 7.6. Lamp Time Read Command 24 7.7. Setting Read Command 24 7.8. Temp Read Command 24
  • Sanyo PLC-WL2503 | RS232C Basic - Page 4
    projector control commands for PLC-WL2500 / WL2501 / WL2503. 1.2. The projector control commands are used to remotely control a projector be changed in service mode. 2.2. Connection Dedicated serial cable must be used for connection to a computer and a projector. PC COM 1 Projector Control Port
  • Sanyo PLC-WL2503 | RS232C Basic - Page 5
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 3. Notes for Communication 1. The projector control command is defined for the interval of 100ms after receiving a response. More than 100ms PC → Projector Projector → PC Command "C" "0" "7" CR ACK CR Next Command Response (A few
  • Sanyo PLC-WL2503 | RS232C Basic - Page 6
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 4. Functional Execution Command Table Command Item C00 POWER ON C01 POWER OFF (Quick Power OFF) C02 POWER OFF C03 ――― C04 HDMI
  • Sanyo PLC-WL2503 | RS232C Basic - Page 7
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications Command C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C4A C4B C4C C4D C4E C4F C50 C51 C52 C53
  • Sanyo PLC-WL2503 | RS232C Basic - Page 8
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 5. Status Read Command Table Command Item CR0 CR1 CR2 Status Read Input Mode Read ――― CR3 (Corresponding) Lamp Time Read CR4 CR5 Setting Read ――― CR6 Temp Read CR7 Lamp Mode Read ――― means no function. Memo 8/25
  • Sanyo PLC-WL2503 | RS232C Basic - Page 9
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6. Functional Execution Command 6.1. Format 6.1.1 PC issues a command in format as below. "C" COMMAND [CR] Command: two characters (See Basic Functional Execution Command Table) A projector changes received data to decode and returns a
  • Sanyo PLC-WL2503 | RS232C Basic - Page 10
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.4. Operation Requirements 1) When the projector's status is any of below, Functional Execution Commands are limited. Projector Status In standby status Countdown in process Cooling Down in process Cooling Down due to Abnormal
  • Sanyo PLC-WL2503 | RS232C Basic - Page 11
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.5. POWER ON Command Command "C00 Power OFF (Standby). The command operates the same Power OFF function as ON/STAND-BY button of the projector and the remote control. Once this command is sent, "Power OFF?" is displayed. If this command
  • Sanyo PLC-WL2503 | RS232C Basic - Page 12
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.10. Computer 2 Command Command "C06" [CR] Detail Select Computer2 Input Although projector returns "OK", Input search is not executed with this command while Input search is set to On1/On2. Note) When "Monitor out" is selected in
  • Sanyo PLC-WL2503 | RS232C Basic - Page 13
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.15. AUDIO MUTE OFF Command Command "C0C" [CR] Detail Sound Mute OFF. This command works the same as "MUTE" button of
  • Sanyo PLC-WL2503 | RS232C Basic - Page 14
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.21. Image Real Command Command "C12" [CR] Detail Set image to Real mode. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.22. Image
  • Sanyo PLC-WL2503 | RS232C Basic - Page 15
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.28. Image Dynamic Command Command "C19" [CR] Detail Set " "[CR] 6.32. BRIGHTNESS + Command Command "C20" [CR] Detail Brightness of User Control +1. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 6.33. BRIGHTNESS -
  • Sanyo PLC-WL2503 | RS232C Basic - Page 16
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.34. IMAGE (Toggle) Command Command "C27"[CR] Detail Switch Image Setting status. This command works the same as "IMAGE" button of
  • Sanyo PLC-WL2503 | RS232C Basic - Page 17
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.40. D.ZOOM + Command Command " On-Screen Display Menu to the right. This command works differently from the pointer ">" of the projector and the remote control, and has no function of Volume +. Acceptable Response [ACK] [CR]
  • Sanyo PLC-WL2503 | RS232C Basic - Page 18
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.46. POINTER UP Command Command "C3C" [CR] Detail Move up the Pointer of On-Screen Display Menu. This command works the same as the pointer "▲" of the projector and the remote control. Acceptable Response [ACK] [CR] Unacceptable "
  • Sanyo PLC-WL2503 | RS232C Basic - Page 19
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.52. Computer 1 RGB (SCART) Command Command "C51"[CR] Detail Select Scart input in Computer1. Although projector returns "OK", Input search is not executed with this command while Input search is set to On1/On2. Acceptable Response
  • Sanyo PLC-WL2503 | RS232C Basic - Page 20
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 6.58. KEYSTONE ↓Command Command "C8F" [CR] Detail Correct keystone distortion by reducing down part of image. Acceptable Response [ACK] [CR] Unacceptable " "[CR] 20/25
  • Sanyo PLC-WL2503 | RS232C Basic - Page 21
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 7. Status Read Command 7.1. Format 7.1.1. PC issues commands in format as below; "CR" Command [CR] Command 1 character(See Basic Status Read Command Table) 7.1.2. When a projector receives the appropriate command, it returns a character
  • Sanyo PLC-WL2503 | RS232C Basic - Page 22
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 7.4.Status Read Command Command "CR0" [CR] Detail Get the projector's operating status to Cooling Down status. This status automatically moves to Standby after lamp turns off and the fan spin finishes after about 90 seconds. The
  • Sanyo PLC-WL2503 | RS232C Basic - Page 23
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications moves to Power OFF status due Down in process after turned off due to lamp failure When a projector is turned off because of lamp failure, it automatically starts Cooling Down operation, in which the projector returns "21" [CR]. "81" [CR
  • Sanyo PLC-WL2503 | RS232C Basic - Page 24
    PLC-WL2500/WL2501/ WL2503 Lamp Time Read Command Command "CR3" [CR] Detail Get the total lamp running hours (Not actual lamp data inside the projector. With some temperature sensors installed in the projector, it is be returned due to hardware %3 problems, the first character becomes "E" like
  • Sanyo PLC-WL2503 | RS232C Basic - Page 25
    PLC-WL2500/WL2501/ WL2503 Basic Serial Command Specifications 7.9.Lamp Mode Read Command Command "CR7" [CR] Detail Get lamp mode status. For 1 lamp projector, get if it is lighting or not. Acceptable "%1" [CR] Response %1 "00" [CR]=Light is out. "01" [CR]=Light is on. Unacceptable " "[CR]
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

BASIC SERIAL COMMAND SPECIFICATIONS
PLC-WL2500
PLC-WL2501
PLC-WL2503
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division