    SPACE WARMER Paraffin / kerosene / diesel HEATERS Model no: AB708.V2, AB7081.V2 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT:
  • Sealey AB7081 | Instruction Manual - Page 2
    temperature (°C) display/error code readout and spare parts storage compartment. Proven pump systems handle heater and check contents. Should there be any damaged or missing parts contact your Sealey stockist immediately. ASSEMBLING FRAME AND WHEELS FOR AB7081 Slide axle through wheel support
  • Sealey AB7081 | Instruction Manual - Page 3
    the troubleshooting guide. NOTE: The electrical components of these heaters are protected by a fuse mounted on the PC board. If the heater will not fire, check this fuse first and replace if necessary. Also check that the proper voltage is being supplied to the heater. © Jack Sealey Limited
  • Sealey AB7081 | Instruction Manual - Page 4
    cooled enough to touch. Unplug the heater from the mains supply before servicing. Use only genuine Sealey replacement parts. Use of alternative/third party components to 3.5mm (0.140"). fig.10 © Jack Sealey Limited Original Language Version fig.11 AB708.V2, AB7081.V2 Issue:8 (ERP) 12/07/19
  • Sealey AB7081 | Instruction Manual - Page 5
    a fuse protected heater. If your heater fails to ignite check the fuse as shown in fig.14 before contacting your local service agent. ‰‰ WARNING! Unplug the heater from the mains is around -40°C. © Jack Sealey Limited Original Language Version AB708.V2, AB7081.V2 Issue:8 (ERP) 12/07/19
  • Sealey AB7081 | Instruction Manual - Page 6
    9. Troubleshooting Problem Possible Cause Heater fires, but main PCB shuts heater off after a short period of time. Lamp is flickering. 1. Incorrect pump pressure 2. Dirty input, output or lint filter 3. Dirty Fuel Filter 4. Nozzle is dirty 5. Photocell
  • Sealey AB7081 | Instruction Manual - Page 7
    fuel local space heaters Model room temperature control kW Two or more manual stages, no room temperature control kW space heating Energy efficiency in active mode ƞs,on 100 % The seasonal space heating energy efficiency ƞs ƞs 90.1 % Energy efficiency classes A Contact details: Sealey
  • Sealey AB7081 | Instruction Manual - Page 8
    space heaters Model identifier(s): AB7081. temperature control kW Two or more manual stages, no room temperature control space heating Energy efficiency in active mode ƞs,on 100 % The seasonal space heating energy efficiency ƞs ƞs 90.1 % Energy efficiency classes A Contact details: Sealey
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

SPACE WARMER PARAFFIN / KEROSENE /
DIESEL HEATERS
MODEL NO:
AB708.V2, AB7081.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
1. SAFETY
1.1.
ELECTRICAL SAFETY
±
WARNING!
It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets
and any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. You
must also read and understand the following instructions concerning electrical safety.
9
Ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections
to ensure that none are loose.
9
Ensure that the voltage marked on the appliance matches the power supply to be
used and that the plug is fitted with the correct fuse - see fuse rating at right.
8
DO NOT
use worn or damaged cables, plugs or connectors. Have any faulty item repaired or
replaced immediately by a competent electrician.
9
It is recommended that this heater is wired directly to a fused isolator switch. If, however, a plug
is fitted, the following applies:
9
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable restraint is tight.
1.2.
GENERAL SAFETY
DANGER!
Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
9
Check that the heater is in sound condition and good working order.
Take immediate action to repair or replace damaged parts.
9
Use recommended parts only.
Unapproved parts may be dangerous and will invalidate the warranty.
9
Only use clean paraffin, kerosene or diesel
(NOT BIO-DIESEL)
to fuel your heater, in accordance with instructions contained in this
manual
±
WARNING!
Only use heater in well ventilated areas. Ensure continuous ventilation from outside of the building is provided to the
heater operating area. Allow at least 3ft² opening/100000Btu/hr output.
9
Keep the front of the heater a minimum of 2.4 metres and the rear and sides1.2 metres from any combustible materials (i.e. wooden
items, cloth, plastics, paper,tarpaulins or similar enclosure materials).
9
Only operate on a level and stable surface.
±
WARNING!
DO NOT
use the heater near flammable material, liquids, solids, gases or compressed gas cylinders.
8
DO NOT
use the heater in closed rooms, living areas, basements or below ground level.
8
DO NOT
allow untrained persons to operate the heater and
DO NOT
operate the heater without the cover.
8
DO NOT
move or handle the heater when hot.
8
DO NOT
leave the heater unattended when in use. Switch the heater off and unplug from the mains before leaving work area.
8
DO NOT
fill the fuel tank whilst the heater is running or still hot.
8
DO NOT
overfill the fuel container. Wipe up any spilt fuel immediately.
8
DO NOT
obstruct the air inlet (rear) and air outlet (front) of the heater.
DO NOT
use duct work in front or at the rear of the heater.
8
DO NOT
look into the exhaust end of the heater.
8
DO NOT
allow children or animals near the heater when in use, or while hot.
±
WARNING! RISK OF ELECTRIC SHOCK. DO NOT
expose the heater to water spray, rain, dripping water or wind.
8
DO NOT
operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT
touch the heater outlet or dome when first switched off as these are very hot and will take time to cool.
9
Ensure that the heater is correctly turned off when not in use and store in a safe, dry area, out of reach of children.
8
DO NOT
unplug the heater to switch it off. Use the ON/OFF switch.
±
WARNING!
Improper maintenance can lead to poor combustion and soot production
NOTE:
This appliance is not intended for persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Recommended fuse rating
13 Amp
Original Language Version
© Jack Sealey Limited
Refer to
instructions
Warning!
AB708.V2, AB7081.V2 Issue:8 (ERP) 12/07/19
Warning!
Hot surfaces
This product is not suitable for primary heating purposes
Warning!
automatic
start-up