Sealey VMSC01 Instruction Manual

Sealey VMSC01 Manual

Sealey VMSC01 manual content summary:

  • Sealey VMSC01 | Instruction Manual - Page 1
    2000W STEAM CLEANER 1.8L TANK MODEL NO: VMSC01.V2 Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS
  • Sealey VMSC01 | Instruction Manual - Page 2
    unattended, after use and before servicing. 9 Stop all controls before room. 2. INTRODUCTION 2000W Steam cleaner with a 1.8L tank, ideal for small Steam Trigger Steam Trigger Lock Latch Pressure Gauge On/Off Tank Filler Cap © Jack Sealey Limited Original Language Version VMSC01
  • Sealey VMSC01 | Instruction Manual - Page 3
    your device normally again. When using the accessories, the surface you are cleaning may be wet. This is due to the steam that turns into water in contact with this surface. Use a sponge or cloth to wipe this surface. © Jack Sealey Limited Original Language Version VMSC01.V2 Issue:2(H) 31/03/22
  • Sealey VMSC01 | Instruction Manual - Page 4
    , SMALL BRUSH, POWER JET TIP 1 2 5.7. WATER Maximum capacity of the water tank is 1.8L. DO NOT OVERFILL. Steam production time is about 35 minutes. Heating time for a full tank is about 10 minutes for a full tank. © Jack Sealey Limited Original Language Version VMSC01.V2 Issue:2(H) 31/03/22
  • Sealey VMSC01 | Instruction Manual - Page 5
    steam. DO NOT use steam on leather, waxed floors, synthetic fabrics, velvet and other fragile materials. When using steam appliances, always refer to the manufacturer's instructions of the body. Hot steam is coming out! © Jack Sealey Limited Original Language Version VMSC01.V2 Issue:2(H) 31/03/22
  • Sealey VMSC01 | Instruction Manual - Page 6
    9. TROUBLESHOOTING PROBLEM The device does not heat up. (In the ON position, . 2 - Disconnect and contact Technical Support. 1 - Add water by following the instructions. 2 - Clean the tank. 3 - Disconnect and contact Steamer Technical Support. The steam flow is irregular, the Appliance "coughs
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2000W STEAM CLEANER 1.8L TANK
MODEL NO:
VMSC01.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
1. SAFETY
1.1.
ELECTRICAL SAFETY
±
WARNING!
It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
Important
: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
8
DO NOT
pull or carry the appliance by the power cable.
8
DO NOT
pull the plug from the socket by the cable.
8
DO NOT
use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is
replaced immediately by a qualified electrician.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY
This electrical appliance produces hot steam from pressurized water. There are several dangers in case of misuse. To prevent
these dangers and to use the device safely, it is necessary to observe the instructions and instructions given in this manual. This
electrical appliance produces hot steam from pressurized water. There are several dangers in case of misuse. To prevent
these dangers and to use the device safely, it is necessary to follow instructions given in this manual.
8
DO NOT
use in any other way than described in this leaflet.
9
This device can be used outdoors. Protection class: IPX4. It should not be stored outdoors, and should not be exposed to rain,
moisture or dew.
DANGER! NEVER TOUCH OR POINT THE STEAM TO YOURSELF OR OTHERS!
9
If excessive steam comes out of the filler cap, turn off the power and disconnect immediately. Stop using the device. For repair,
contact a qualified technician.
9
The pressure indicator needle (manometer) should be in the red zone. The normal operating pressure is 5 bar.
If the needle is in the
yellow zone, the pressure is insufficient.
8
DO NOT
use the device without water in the tank.
8
DO NOT
open the filling port during use.
8
DO NOT
operate the appliance without tightening the filler cap securely.
8
DO NOT
overfill the water tank. The maximum capacity of Steamer is 1.8L of water. Standard capacity is 1.6L. Excessive filling of the
water tank may cause malfunctions, property damage or injury.
8
DO NOT
return or tilt the Steamer more than 45° when it is energized or if it still produces steam.
9
The device does not contain any user-serviceable parts.
8
DO NOT
use if damaged.
DO NOT
use if steamer has been dropped, if there are visible signs of damage or if there is a leak.
DO NOT
attempt any repairs. Steamer must only be repaired by qualified electricians. If the power cable is damaged, it must be
replaced by suitably qualified persons.
8
DO NOT
use near swimming pools containing water.
±
WARNING!
: Danger of burning by hot liquid and steam.
Refer to
instruction
manual
Wear eye
protection
Wear protective
gloves
Keep away
from rain
Hot surface
Steam
Original Language Version
© Jack Sealey Limited
Recommended fuse rating
13Amp
V
MSC01.V2
Issue:2(H)
31/03/22