  • Seiko 6R20 | Manual - Page 1
    Cal. 6R20 INSTRUCTIONS BEDIENUNGSANLEITUNG INSTRUCTIONS ISTRUZIONI INSTRUCCIONES INSTRUÇÕES (P. 3) (S. 25) (P. 47) (P. 69) (P. 91) (P. 113) (135 )
  • Seiko 6R20 | Manual - Page 2
    now the proud owner of a SEIKO Automatic Watch Cal. 6R20. To ensure its optimum performance, please read the instructions in this booklet carefully before using it. Please keep this manual handy for ready reference. Sie sind jetzt stolzer Besitzer einer SEIKO Automatikuhr Kal. 6R20. Lesen Sie diese
  • Seiko 6R20 | Manual - Page 3
    A MECHANICAL WATCH 4 NAMES OF THE PARTS 5 HOW TO USE ...7 HOW TO SET THE TIME, DAY AND DATE 9 HOW TO READ THE POWER RESERVE INDICATOR 12 TO PRESERVE THE QUALITY OF YOUR WATCH 14 PLACES TO KEEP YOUR WATCH 18 NOTES ON OVERHAUL 19 NOTES ON GUARANTEE AND REPAIR 19 TROUBLESHOOTING 20 ACCURACY OF
  • Seiko 6R20 | Manual - Page 4
    . 6R20 CHARACTERISTICS OF A MECHANICAL WATCH (self-winding type, automatic winding type) ● This mechanical watch operates using power obtained from a mainspring. ● If the watch is completely stopped, manually turn the crown approximately 20 times to wind up the mainspring to start the watch. ● While
  • Seiko 6R20 | Manual - Page 5
    English NAMES OF THE PARTS Hour hand Power reserve indicator Second hand Minute hand Date CROWN abc Day CROWN a) Normal position : winding up the mainspring (manual operation) b) First click position : day and date settings c) Second click position : time settings 5
  • Seiko 6R20 | Manual - Page 6
    by turning it counterclockwise. 6OTDSFX Go to "HOW TO USE" 4DSFXVQ * If your watch has a screw-lock crown, the crown will screw into the watch case for added protection. • After completing all settings of the watch, screw the crown in again by turning it clockwise while pressing it. • If the
  • Seiko 6R20 | Manual - Page 7
    English HOW TO USE This watch is an automatic watch equipped with a manual winding mechanism. • When the watch is worn on the wrist, the motion of the wearer's arm winds the mainspring of the watch. • If your watch is completely stopped, it is recommended that you manually wind the mainspring by
  • Seiko 6R20 | Manual - Page 8
    of the mainspring, refer to "HOW TO READ THE POWER RESERVE INDICATOR " on page 12. * There is no need to turn the crown further when the mainspring is fully wound. But the crown can be turned without damaging the watch mechanism. * Once the watch is wound up fully, it operates for about 45 hours
  • Seiko 6R20 | Manual - Page 9
    around 12 o'clock noon, and the day around 2:00 p.m. 1. Pull out the crown to the first click. (The second hand continues moving and the accuracy of the watch is unimpaired.) 2. The day can be set by turning the crown clockwise. 3. The date can be set by turning the crown counterclockwise. Turn it
  • Seiko 6R20 | Manual - Page 10
    correct time. 5. Push the crown back in to the normal position in accordance with a time signal. CAUTION • The mechanism of mechanical watches is different from that of quartz watches. When setting the time, be sure to turn back the minute hand a little behind the desired time and then advance it to
  • Seiko 6R20 | Manual - Page 11
    that has less than 31 days. Ex.) To adust the date in the a.m. period on the first day of a month following a 30-day month. 1. The watch displays "31" instead of "1". Pull out the crown to the first click. 2. Turn the crown to set the date to "1" and then push the crown
  • Seiko 6R20 | Manual - Page 12
    English HOW TO READ THE POWER RESERVE INDICATOR • The power reserve indicator lets you know the winding state of the mainspring. • Before removing the watch from your wrist, observe the power reserve indicator to check if the watch has enough power stored to keep running until the next time you
  • Seiko 6R20 | Manual - Page 13
    the mainspring is fully wound, the crown can be turned further without damaging the mainspring itself. The mainspring of the watch employs a slipping mechanism to prevent the mainspring from over-winding. * The orientation of "the power reserve indicator" may slightly vary depending on the model. 13
  • Seiko 6R20 | Manual - Page 14
    directly. Keep the case and band clean at all times. This will help to extend the life of the watch and will reduce the risk of skin irritations. • When you take the watch off, wipe off moisture, sweat or soil with a soft dry cloth as soon as possible. This will help to
  • Seiko 6R20 | Manual - Page 15
    metals or leathers • Rust, contamination or perspiration accumulated on the watch case or band. • If you should develop any allergic symptoms the case back, your watch is not water resistant, and care should be taken not to get it wet as water may damage the movement. If the watch becomes wet, we
  • Seiko 6R20 | Manual - Page 16
    for wearing while taking a bath or shallow diving, but not for scuba diving. We recommend that you wear a SEIKO Diver's watch while scuba diving. * Before using a water resistant 5, 10, 15 or 20 bar watch in water, make sure the crown is pushed in completely. Do not operate the crown when the
  • Seiko 6R20 | Manual - Page 17
    should not be considered as corresponding to an actual diving depth since swimming movements tend to increase the pressure at a given depth. Care should also be taken when diving with the watch into water. PRECAUTIONS ON WEARING YOUR WATCH • Exercise care when you hold an infant or small child while
  • Seiko 6R20 | Manual - Page 18
    near television sets, loudspeakers or magnetic necklaces) or static electricity. ● Do not leave the watch where there is strong vibration. ● Do not leave the watch in dusty places. ● Do not expose the watch to chemical substances or gases. (Ex.: Organic solvents such as benzine and thinner, gasoline
  • Seiko 6R20 | Manual - Page 19
    with special oils. If the parts run short of oil or get worn out, the watch may lose time or stop its operation. In such a case, have the watch overhauled. NOTES ON GUARANTEE AND REPAIR ● Please contact the retailer the watch was purchased from or SEIKO CUSTOMER SERVICE CENTER for repair or overhaul
  • Seiko 6R20 | Manual - Page 20
    indicator of time, or the amount of does not move up. arm movement is small. Wear the watch for an extended period of time, or when taking off the watch, turn the crown to wind the mainspring if the remaining power shown by the power reserve indicator is not sufficient for the next use. The
  • Seiko 6R20 | Manual - Page 21
    of one week or so. ● The accuracy of mechanical watches may not fall within the specified range of time accuracy because of loss/gain changes due to the conditions of use, such as the length of time during which the watch is worn on the wrist, arm movement, and whether the mainspring is wound up
  • Seiko 6R20 | Manual - Page 22
    a strong magnetism from outside, the mechanical watch may loss/gain time temporarily. The parts of the watch may become magnetized depending on the extent of the effect. In such a case, consult the retailer from whom the watch was purchased since the watch requires repair including demagnetizing. 22
  • Seiko 6R20 | Manual - Page 23
    Continuous operating time More than approx. 45 hours 5 Driving system Automatic winding type with manual winding mechanism 6 Jewels 29 jewels * The accuracy above is factory adjusted. ** Due to the characteristics of mechanical watches, any actual daily rate may not fall within the range of time
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Cal. 6R20
INSTRUCTIONS
(P.
3)
BEDIENUNGSANLEITUNG
(S.
25)
INSTRUCTIONS
(P.
47)
ISTRUZIONI
(P.
69)
INSTRUCCIONES
(P.
91)
INSTRUÇÕES
(P. 113)
(135
)