TeamConnect Ceiling 2 Planning Guide for System Integrators Sennheiser electronic GmbH & Co. KG Am Labor 1, 30900 Wedemark, Germany, www.sennheiser.com 2023-01 | v2.0 - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 2
Planning guide for system integrators TeamConnect Ceiling 2 Contents Introduction...3 Intended use...3 Requirements for the room...3 Background noise level...3 Room dimensions...4 Installation options...5 Classic installation in or below the ceiling 5 Alternative installation in the room ...6 - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 3
the TeamConnect Ceiling 2 (TCC2) in a room. This planning guide contains recommendations for the optimal positioning of one or more TCC2 units in various room scenarios. Sennheiser electronic GmbH & Co. KG provides both 2D and 3D CAD files to enable accurate simulation of the coverage area - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 4
Planning guide for system integrators TeamConnect Ceiling 2 Room dimensions The TCC2's coverage radius determines the be suspended up to 5m (16ft) from the ceiling using the optional suspension kit. Suspending the device from a higher ceiling (> 5m (16ft)) requires a customized suspension solution, - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 5
Planning guide for system integrators TeamConnect Ceiling 2 Installation options The TCC2 can be installed in two different ways: • Installation below the ceiling (four variants) • Installation in the room (two variants) For each variant, there are certain minimum and maximum distances that must be - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 6
guide for system integrators TeamConnect Ceiling 2 Alternative installation in the room In addition to the classic installation in or below the ceiling decorative walls or ceilings, etc., the TCC2 can be mounted upside down on a pedestal in the middle of the room. With flexible coverage of 180° - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 7
Planning guide for system integrators TeamConnect Ceiling 2 Minimum and maximum distances in the room Each presenters. A microphone that is suspended too low or too high may result in a loss of level and clarity in detected speech, as participants may be outside the actual coverage radius (see - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 8
Planning guide for system integrators TeamConnect Ceiling 2 Mounting on a pedestal in the room With the "Variant 5" installation option (on a pedestal in the room), we recommend adhering to the following distances during planning: • - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 9
Planning guide for system integrators TeamConnect Ceiling 2 Adapting to the room Thanks to its dynamic beamforming technology, the TCC2 can adapt to almost any room configuration. You can select individual Exclusion and - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 10
Round tables (d=2m) 10 m (33 ft) Planning guide for system integrators TeamConnect Ceiling 2 18 m (59 ft) 10 m (33 ft) 10 m (33 ft) 6 m (20 ft) 5 m (16 ft) Ex. 1: Medium-sized conference room Size: 100 m² (1076 ft²) Tables/persons: 8/16 - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 11
Planning guide for system integrators TeamConnect Ceiling 2 Positioning in the room For maximum coverage in the room, the TCC2 should be positioned so that it covers the entire area to be detected from a central position. In some cases the preferred central position in the room's ceiling may be - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 12
integrators TeamConnect Ceiling 2 Some rooms are equipped with technologies that cause additional noise or interference. Such sources of interference could be an air conditioner, a coffee machine, or the fan noise from a ceiling-mounted projector that is mounted near the ceiling microphone. To - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 13
Obstacles on the ceiling Planning guide for system integrators TeamConnect Ceiling 2 If there are obstacles on the ceiling, such as and clearly picks up the noise from the cooling fan. The Control Cockpit software precisely localizes the incoming audio signals and visualizes them with a yellow dot - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 14
Planning guide for system integrators TeamConnect Ceiling 2 Sound distribution The recommended distances for Zone Sensitivity Threshold The Sensitivity Threshold setting lets you adjust the TCC2 microphone's sensitivity to background noise in order to better identify the presenter. Depending - Sennheiser TeamConnect Ceiling 2 | TeamConnect Ceiling 2 - Planning Guide for Sy - Page 15
mounting frame SL CM EB US Angle brackets (for 2ft ceiling grid) SL CM EB 625 Angle brackets (for 625mm ceiling grid) SL CM SK Ceiling suspension kit SL CM VB VESA adapter Planning guide for system integrators TeamConnect Ceiling 2 M4x8 Art. no. 506846 6.4 mm M4x12 Art. no. 508528 M3x8
TeamConnect Ceiling 2
Planning Guide for System Integrators
Sennheiser electronic GmbH & Co. KG
Am Labor 1, 30900 Wedemark, Germany, www.sennheiser.com
2023-01 | v2.0