- Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 1
AF-S50CX AF-S60CX AF-R50CX AF-R55CX AF-R60CX AF-R70CX ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL CONTENTS PAGE FOR YOUR PROTECTION 2 CONSUMER LIMITED WARRANTY ..... 3 INSTALLATION INSTRUCTIONS STAR Partner, Sharp Electronics has determined that these products (AF-S50CX, AFS60CX) - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 2
PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 3
Where to Obtain Service: What to Do to Obtain Service: AF-S50CX, AF-S60CX, AF-R50CX, AF-R55CX, AF-R60CX or AF-R70CX Room Air Conditioner Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 4
Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for proper installation. CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash- - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 5
INSTALLATION INSTRUCTIONS ACCESSORIES No. Accessories Q'ty 1 Right closure assembly 1 2 2 Left closure assembly 1 3 Window sash foam seal 1 4 Window sash foam seal (adhesive type) 1 3 5 Bottom gasket 1 6 Screws (L=1", 25.4mm) 7 4 7 - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 6
INSTALLATION INSTRUCTIONS INSTALLATION WARNING: Make sure the unit is turned off and unplugged before working. 1 Cut the window sash foam seal (adhesive type) to the proper length - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 7
INSTALLATION INSTRUCTIONS 5 Insert the closure assemblies on both sides into the rails of the jamb. Jamb (Left) Closure assembly (Left) Sill 6 Loosen screws on both sides of - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 8
FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manual. • Make sure the unit is the correct capacity for the area you want to cool. • Do not modify any part - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 9
PRECAUTIONS NOTES ON OPERATION • Allow 3 minutes for the compressor to restart cooling. If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor off three minutes for - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 10
handle 10 to the right to remove.) 0Filter Handle qPower Cord CONTROL PANEL AF-S50CX, S60CX, R50CX, R60CX, R70CX 2 1 11 F POWER hr ON/OFF 10 3 COOL / FAN TEMP SELECTOR TIMER ON/OFF ENERGY SAVER AF-R55CX 2 1 11 F POWER hr ON/OFF 10 3 COOL / FAN TEMP SELECTOR TIMER ON - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 11
COOLING OPERATION HOW TO OPERATE SELECTOR indicator POWER indicator F POWER hr ON/OFF COOL / FAN TEMP SELECTOR TIMER ON/OFF ENERGY SAVER POWER ON/OFF pad 1 Touch POWER ON/OFF pad. • The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on. - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 12
HOW TO OPERATE TO CHANGE FAN SPEED AND OPERATION MODE SELECTOR indicator F POWER hr ON/OFF COOL / FAN TEMP SELECTOR TIMER ON/OFF ENERGY SAVER SELECTOR pad During operation Touch SELECTOR pad and select the operation mode and fan speed. • SELECTOR indicator and display will light in order - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 13
HOW TO OPERATE ENERGY SAVER During normal operation, the thermostat automatically controls cooling and the fan runs continuously. When the ENERGY SAVER is selected, the thermostat automatically controls cooling and the fan automatically stops when the compressor is not operating. (Fan will stop 30 - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 14
HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 15
HOW TO OPERATE OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 16
HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two size-AAA (R03) batteries. 1 Remove the battery compartment cover. 2 Insert the batteries in the compartment, making sure the and polarities are properly aligned. Battery compart- 3 Replace the cover. ment cover NOTES: • - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 17
HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER POWER ON/OFF TEMP. TEMP. SELECTOR SET TIMER/OFF POWER ON/OFF button Push to start or stop the operation. TEMPERATURE setting button TEMP. ---Raise temp. setting 1°F at a time. TEMP. ---Lower temp. setting 1°F at a time. SELECTOR button - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 18
CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. At the beginning of every cooling season or after a long period of inactivity, clean the filter - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 19
BEFORE CALLING FOR SERVlCE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY, PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in or is the plug loose? • Is the fuse blown or the circuit breaker - Sharp AF-R50CX | AF-R50CX , AF-R60CX , AF-R70CX Operation Manual - Page 20
SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TINSEA292JBRZ 01LO TL 1
AF-S50CX
AF-S60CX
AF-R50CX
AF-R55CX
AF-R60CX
AF-R70CX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
PAGE
CONTENTS
This INSTALLATION AND OPERATION
MANUAL explains the proper use of your
new
Sharp Air Conditioner. Read these instructions
carefully before installing
or operating
your air
conditioner. The INSTALLATION
AND
OP-
ERATION
MANUAL
should be kept in a safe
place for handy reference.
FOR YOUR PROTECTION
....................
2
CONSUMER LIMITED WARRANTY
.....
3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA
........................
4
• LOCATlON
..............................................
4
• ACCESSORIES
......................................
5
• SUGGESTED TOOLS
............................
5
• INSTALLATION
.......................................
6
PRECAUTIONS
•
CAUTION FOR USE
............................
8
• GROUNDING INSTRUCTIONS
...........
8
• NOTES ON OPERATION
....................
9
• ENERGY EFFICIENCY TIPS
...............
9
HOW TO OPERATE
•
PARTS NAMES
...................................
10
•
COOLING OPERATION
......................
11
•
TO CHANGE TEMPERATURE SETTING
..........
11
•
TO CHANGE FAN SPEED AND OPERATION MODE ..
12
• ENERGY SAVER
.................................
13
•
TO CHANGE AIR FLOW DIRECTION
.......
13
• ON TIMER OPERATION
.....................
14
• OFF TIMER OPERATION
....................
15
• USING THE REMOTE CONTROL
.......
16
CLEANING AND MAINTENANCE
........
18
BEFORE CALLING FOR SERVlCE
......
19
As an ENERGY STAR Partner, Sharp Electronics has determined that these products (AF-S50CX, AF-
S60CX) meet the ENERGY STAR guidelines for energy efficient air conditioners.
To meet these guidelines,
air conditioners must be at least 15% more efficient than the minimum Federal standard.