Sharp EL-W516 EL-W506 , EL-516 , EL-W546 Operation Manual

Sharp EL-W516 Manual

Sharp EL-W516 manual content summary:

  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 1
    operations and function calculations. STAT mode: b 1 Used to perform statistical operations. DRILL mode: b 2 Used to practice math and multiplication table drills. CPLX mode: b 3 Used to perform complex number calculations. MATRIX mode: b 4 Used to perform matrix calculations. LIST mode: b 5 Used
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 2
    with or without π) ⾳ decimal numbers • Proper fractions (with or without π) ⾳ decimal numbers • Irrational numbers (square roots, fractions made using square roots) ⾳ decimal numbers Notes: • In the following cases, calculation results may be displayed using r: • Arithmetic operations and memory
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 3
    . If the number of subintervals is not specified, the default value of n = 100 will be used. 3. Press =. Notes: • Parameters are entered in the following way: WriteView editor: b a function[, subintervals]dx Line editor: (function, a, b[, subintervals]) • Integral calculations, depending on
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 4
    be recalled after entering multiple instructions or when the calculation result is in matrix/list format. Fraction Calculations 12 Arithmetic operations and memory calculations can be performed using fractions. In NORMAL mode, conversion between a decimal number and a fraction can be performed by
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 5
    change in subsequent operations. • When using the WriteView editor, if the calculation result is displayed using fractions or irrational numbers, press U to convert it to decimal form first. • The modify function can be used in NORMAL, STAT, MATRIX, or LIST modes. Simulation Calculation (ALGB) 19
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 6
    +]>) Mixed operators: Questions within all the above ranges are displayed. COMPLEX NUMBER CALCULATIONS 25 To carry out addition, subtraction, multiplication, and division using complex numbers, press b 3 to select CPLX mode. Results of complex number calculations are expressed using two systems
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 7
    the WriteView editor. Ex. @ * 5 r A l N In this example, delete the exponent before attempting to delete the parentheses. Cannot call! • The function or operation stored in definable memory (D1 to D4) cannot be called. Ex. An attempt was made to recall a statistical variable from within NORMAL mode
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 8
    fic calculations, complex number calculations, equation solvers, statistical calculations, etc. Drill features: Math Drill and Multiplication Table Display: 96 × 32 dot matrix liquid crystal display Display of calculation results: Mantissa: 10 digits Exponent: 2 digits Internal calculations
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 9
    EL-W506 EL-W516 EL-W546 CALCULATION EXAMPLES EXEMPLES DE CALCUL ANWENDUNGSBEISPIELE EJEMPLOS DE CÁLCULO EXEMPLOS DE CÁLCULO ESEMPI DI CALCOLO REKENVOORBEELDEN PÉLDASZÁMÍTÁSOK PŘÍKLADY VÝPOČTŮ RÄKNEEXEMPEL LASKENTAESIMERKKEJÄ UDREGNINGSEKSEMPLER CONTOH-CONTOH PERHITUNGAN 陹ꩥ꾽 PRINTED IN CHINA /
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 10
    500. 3 x Y 3. @ s ; Y A = U 28.27433388 24 z ( 4 + 6 ) = 2 ⎯52 3 k ; < + 60 z ; < = 32 ⎯15 @ s ; Y A x [ jF1 3 x Y 3. 4 3 V=? sinh−1 ˰ D1 t [ k 4 z 3 = U 37.69911184 x I @ > v sinh−1 0.5 = I 0.5 = 0.481211825 11 6 + 4 = ANS j 6 + 4 = ANS + 5 = + 5 = 8 × 2 = ANS 8 k 2 = ANS2
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 11
    05: ydˠm 20: Lˠgal (US) 35: psˠW 06: mˠyd 21: gal (UK)ˠL 36: Wˠps 07: miˠkm 22: Lˠgal (UK) 37: kgf/cm2ˠPa 08: kmˠmi 23: fl oz(US)ˠmL 38: Paˠkgf ˠfl oz(US) 39: atmˠPa 10: mˠn mi 25: fl oz(UK)ˠmL 40: Paˠatm 11: acreˠm2 26: mLˠfl oz(UK) 41: mmHgˠPa 12: m2ˠacre 27: calthˠJ 42: PaˠmmHg
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 12
    DATA xy 25 b 1 1 @ Z 2 H 5 _ S#a# 1 [LINE] 0. DATA SET= 1. 25 _ DATA SET= 2. 12 24 21 40 21 40 21 40 15 25 a = 12 H 24 _ DATA SET= 3. 21 H 40 H 3 _ DATA SET= 4. 15 H 25 _ DATA SET= 5. t a a= 1.050261097 b = t b b= 1.826044386 r = t f sx = t v r= 0.995176343 sx= 8.
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 13
    26 b (MATRIX) [ ]1 2 3 4 ˰ matA b 4 N 2 2 2 e 1 e 2 e 3 e 4 e j N 4 0 [ ]3 1 ˰ matB 26 N 2 e 3 e 1 e 2 e 6 e j N 4 1 29 Function keys Display of memory used for the display in the WriteView editor, el editor WriteView, medida en caracteres (excluyendo los valores introducidos, indicados en el
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 14
    30 Function Fonction Funktion Función Função Funzioni Functie Függvény Funkce Funktion Funktio Funktion Dynamic range Plage dynamique zulässiger Bereich Rango dinámico Gama dinâmica
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 15
    usagée ou à votre revendeur ou au service après-vente, pour recyclage. • de ne help Users. 1. In the European Union If the product is used for business purposes and you want to discard it: Please contact your SHARP Unión Europea pueden devolver sus equipos eléctricos y electrónicos a los centros
  • Sharp EL-W516 | EL-W506 , EL-516 , EL-W546 Operation Manual - Page 16
    als u dit wilt weggooien: Neem contact op met uw SHARP distributeur die u inlichtingen verschaft over de terugname van het product ámí s vhodnou metodou likvidace. Figyelem: A terméket ezzel a jelöléssel látták el. Ez azt jelenti, hogy a használt elektromos és elektronikus termékeket nem szabad az
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

PRINTED IN CHINA / IMPRIMÉ EN CHINE / IMPRESO EN CHINA
07HGK (TINSE1307EHZZ)
INTRODUCTION
Thank you for purchasing the SHARP Scientific Calculator
Model EL-W506/W516/W546.
About the
calculation examples (including some formulas
and tables)
, refer to the
calculation example
sheet.
Refer to
the number on the right of each title in the manual for use.
After reading this manual, store it in a convenient location for
future reference.
Notes:
• Some of the models described in this manual may not be
available in some countries.
• This product uses a period as a decimal point.
Operational Notes
• Do not carry the calculator around in your back pocket, as it
may break when you sit down. The display is made of glass
and is particularly fragile.
Keep the calculator away from extreme heat such as on a
car dashboard or near a heater, and avoid exposing it to
excessively humid or dusty environments.
• Since this product is not waterproof, do not use it or store
it where fluids, for example water, can splash onto it.
Raindrops, water spray, juice, coffee, steam, perspiration,
etc. will also cause malfunction.
• Clean with a soft, dry cloth. Do not use solvents or a wet cloth.
• Do not drop it or apply excessive force.
• Never dispose of batteries in a fire.
• Keep batteries out of the reach of children.
• For the sake of your health, try not to use this product for
long periods of time. If you need to use the product for an
extended period, be sure to allow your eyes, hands, arms,
and body adequate rest periods (about 10–15 minutes
every hour).
If you experience any pain or fatigue while using this
product, discontinue use immediately. If the discomfort
continues, please consult a doctor.
• This product, including accessories, may change due to
upgrading without prior notice.
NOTICE
• SHARP strongly recommends that separate permanent
written records be kept of all important data. Data may be
lost or altered in virtually any electronic memory product
under certain circumstances. Therefore, SHARP assumes
no responsibility for data lost or otherwise rendered
unusable whether as a result of improper use, repairs,
defects, battery replacement, use after the specified
battery life has expired, or any other cause.
• SHARP will not be liable nor responsible for any incidental
or consequential economic or property damage caused
by misuse and/or malfunctions of this product and its
peripherals, unless such liability is acknowledged by law.
Press the RESET switch (on the back), with the tip of a
ball-point pen or similar object, only in the following cases:
• When using for the first time
• After replacing the battery
• To clear all memory contents
• When an abnormal condition occurs and all keys are
inoperative
Do not use an object with a breakable or sharp tip. Note that
pressing the RESET switch erases all data stored in memory.
If service should be required on this calculator, use only a
SHARP servicing dealer, SHARP approved service facility, or
SHARP repair service where available.
Hard Case
Remove the hard case, holding it with your fingers in the
positions shown below.
DISPLAY
Dot
matrix
display
Symbol
Mantissa
Exponent
• During actual use, not all symbols are displayed at the same time.
• Only the symbols required for the usage currently being explained
are shown in the display and calculation examples in this manual.
/
/
:
Indicates that some contents are hidden in the
directions shown.
2ndF
:
Appears when
@
is pressed, indicating that the
functions shown in orange are enabled.
HYP
:
Indicates that
H
has been pressed and the
hyperbolic functions are enabled. If
@
>
is
pressed, the symbols
2ndF HYP
appear, indicating that
inverse hyperbolic functions are enabled.
ALPHA
: Indicates that
;
,
x
or
t
has been pressed,
and entry (recall) of memory contents and recall of
statistics can be performed.
DEG/RAD/GRAD
: Indicates angular units.
BUSY
:
Appears during the execution of a calculation.
W-VIEW
: Indicates that the WriteView editor is selected.
M
:
Indicates that a numerical value is stored in the
independent memory (M).
/
:
Indicates the mode of expression for results in CPLX mode.
ENG/SCI/FIX/N2/N1
: Indicates the notation used to display a
value and changes by SET UP menu.
N1
is displayed
on-screen as “NORM1”, and
N2
as “NORM2”.
BEFORE USING THE CALCULATOR
When using for the first time, press the RESET switch (on the
back), with the tip of a ball-point pen or similar object.
Adjusting the Display Contrast
Press
@
J
3
, then
+
or
&
to adjust the
contrast. Press
j
to exit.
Power On and Off
Press
j
to turn the calculator on. The data that was on-
screen when the power was turned off will appear on the display.
Press
@
o
to turn the calculator off.
Key Notations Used in this Manual
In this manual, key operations are described as follows:
To specify
e
x
:
@
"
To specify ln:
i
To specify E:
;
E
• Functions that are printed in orange above the key require
@
to be pressed first before the key. When you specify the
memory, press
;
first. Numbers for input values are not
shown as keys, but as ordinary numbers.
• Functions that are printed in gray adjacent to the keys are
effective in specific modes.
• The multiplication operator “
×
” is differentiated from the letter
“X” in this manual as follows:
To specify the multiplication operator:
k
To specify the letter “X”:
;
X
The WriteView and Line Editors
This calculator has the following two editors in NORMAL mode:
WriteView and Line. You can select between them in the SET UP
menu.
The WriteView editor (default)
The Line editor
Notes:
• The WriteView Editor is only available in NORMAL mode.
• In certain calculation examples, where you see the
o
symbol, the key operations and calculation results are shown
as they would appear in the Line editor.
Clearing the Entry and Memories
Operation
Entry
(Display)
A–F,
M, X, Y
*
1
F1–F4,
D1–D4
*
2
ANS STAT
*
3
matA–D
*
4
L1–L4
*
5
j
×
×
×
×
×
@
Z
×
×
Mode selection (
b
)
×
×
×
×
*
6
@
P
0
*
7
×
×
×
×
×
@
P
1
0
*
7
@
P
2
0
*
7,
*
8
RESET switch*
8
: Clear
×
: Retain
*1 Press
j
x
and then choose a memory to clear one
variable memory.
*2 Formula memories and definable memories. See “Memory
Calculations”.
*3 Statistical data (entered data)
*4 Matrix memories (matA, matB, matC, and matD)
*5 List memories (L1, L2, L3, and L4)
*6 Cleared when changing between sub-modes in STAT mode.
*7 See “Memory clear key”.
*8 The username you stored using the name display function will
be cleared as well.
Memory clear key
Press
@
P
to display the menu.
• To initialize the display settings,
press
0
. The parameters are
set as follows:
• Angular unit: DEG
• Display notation: NORM1
• N-base: DEC
• To clear all variables and memories (A±F, M, X, Y, F1±F4, D1±D4,
ANS, STAT, matA±D, and L1±L4) at once, press
1
0
.
• To RESET the calculator, press
2
0
. The RESET
operation will erase all data stored in memory and restore
the calculator’s default settings. You can do the same thing by
pressing the RESET switch on the back of the calculator.
Mode Selection
d
NORMAL mode:
b
0
(default)
Used to perform arithmetic operations and function calculations.
STAT mode:
b
1
Used to perform statistical operations.
DRILL mode:
b
2
Used to practice math and multiplication table drills.
CPLX mode:
b
3
Used to perform complex number calculations.
MATRIX mode:
b
4
Used to perform matrix calculations.
LIST mode:
b
5
Used to perform list calculations.
EQUATION mode:
b
6
Used to solve equations.
EL-W506
EL-W516
EL-W546
SCIENTIFIC CALCULATOR
OPERATION MANUAL
MODEL
ENGLISH