Sharp ER-A410 ER-A410 ER-A420 Operation Manual - Page 108
Programming Non-PLU code format
View all Sharp ER-A410 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Programming Non-PLU code format PGM 2 2025 The register allows you to specify the Non-PLU code format (flag code: 2, 02, 20 -29). The format data is as follows: Flag (02 or 20-29) Free format C D 2 C D Free format Flag Price check digit Procedure . ` 2025 Field 1 Field 2 Free format area *1 Flag code (max. 2 digits) ` To delete *2 ABCDEF ı c *1 Flag code: 2, 02, 20 - 29 *2 Item: A Length of field 1 (number of digits) B Length of field 2 (number of digits) C Always enter 0. D Meaning of field 2*3 E Price check digit used F TAB or decimal point of field 2 (0, 1, 2, 3) Selection: (Fixed position) Quantity Price Yes No Entry: 0 - 9 0 - 9 0 2 0 1 0 0 - 3 *3: When you preset a quantity, the sales amount is calculated as follows: quantity x unit price programmed in #1210. Example 20 Flag code P D PLU no. Price check digit C D Price (TAB2) Key operation 2025 . ` 20 ` 540012 ı c Print Flag code ABCDEF 106